Yokogawa DCS I/O and Communication Modules
Yokogawa ANT411 / ANT512 DCS I/O
CoversANT411 / ANT512
Yokogawa ANT411 (master, in the FCU) and ANT512 (slave) optical ESB bus repeater modules for 5–50 km links to ANB11 node units; ANT401/ANT502 cover up to 5 km.
- ANT512
- Optical ESB bus repeater slave module for 5 km to 50 km
- 5 km versions
- ANT401 (master) and ANT502 (slave)
- Node unit power (ANB11)
- 100–120 V AC, 220–240 V AC or 24 V DC, by suffix code
Availability and lead time confirmed on request
Overview
Yokogawa ANT411 / ANT512 Optical ESB Bus Repeater Modules (5–50 km)
We can supply the Yokogawa ANT411 / ANT512 Optical ESB Bus Repeater Modules (ANT411 / ANT512): HKXYTECH is an independent supplier and every unit is 100% original and brand-new. Lead time is quoted per inquiry. We ship worldwide by DHL, UPS or FedEx air express or by sea freight, accept payment by T/T (your local currency is also supported) and reply to every inquiry within 24 hours.
ANT411 and ANT512 link a field control unit to a remote node unit over optical ESB bus for 5–50 km. ANT411 is the master in the FCU; ANT512 is the slave side. For distances up to 5 km Yokogawa uses ANT401 and ANT502 instead.
Option code shown in the GS for ANB11
| /BU1A | Connector unit for ESB bus (ANB11 option) |
|---|---|
| /BU1B | Connector unit with terminator for ESB bus (ANB11 option) |
| /HU1A | Connector unit for ESB bus with HKU interface (ANB11 option) |
| /HU1B | Connector unit with terminator for ESB bus with HKU interface (ANB11 option) |
Before you order
- The GS shows which ANT411 suffix pairs with which node unit, but does not decode the ANT411 or ANT512 suffixes themselves. Codes on the old pages (for example /CU1N, /CU1T) are not in this GS; confirm against the module label.
Order codes in this series
48 order codes from this series are collected on this page. Send the full code from the label or your parts list when you ask for a quote.
Show all 48 codes
ANT411-0E/CU1NANT411-0E/CU1TANT411-0F/CU1NANT411-0F/CU1TANT411-00/CU1NANT411-00/CU1TANT411-03/CU1NANT411-03/CU1TANT411-E0/CU1NANT411-E0/CU1TANT411-E3/CU1NANT411-E3/CU1TANT411-EE/CU1NANT411-EE/CU1TANT411-EF/CU1NANT411-EF/CU1TANT512-0E/BU1AANT512-0E/BU1BANT512-0E/HU1AANT512-0E/HU1BANT512-0F/BU1AANT512-0F/BU1BANT512-0F/HU1AANT512-0F/HU1BANT512-00/BU1AANT512-00/BU1BANT512-00/HU1AANT512-00/HU1BANT512-03/BU1AANT512-03/BU1BANT512-03/HU1AANT512-03/HU1BANT512-E0/BU1AANT512-E0/BU1BANT512-E0/HU1AANT512-E0/HU1BANT512-E3/BU1AANT512-E3/BU1BANT512-E3/HU1AANT512-E3/HU1BANT512-EE/BU1AANT512-EE/BU1BANT512-EE/HU1AANT512-EE/HU1BANT512-EF/BU1AANT512-EF/BU1BANT512-EF/HU1AANT512-EF/HU1B
Frequently asked questions
Can you ship the Yokogawa ANT411 / ANT512 Optical ESB Bus Repeater Modules to my country?
We ship by DHL, UPS or FedEx air express, or by sea freight. Send the destination with your inquiry; lead time and freight are quoted per inquiry.
Is the Yokogawa ANT411 / ANT512 Optical ESB Bus Repeater Modules original and brand-new?
Yes. We supply 100% original, brand-new units. HKXYTECH is an independent supplier and is not affiliated with the manufacturer.
Do you provide a test report or certificate of origin (COO)?
Tell us which documents you need when you send the inquiry. We confirm per order which documents can be supplied with the unit.
Do you have stock for an urgent or shutdown replacement?
Stock changes daily, so availability is confirmed per inquiry. Send the full order code from the nameplate and mark the inquiry urgent; we reply within 24 hours with availability and lead time.
What if my model is discontinued?
Send the full order code from the nameplate. If the exact configuration is no longer made, we check the current equivalent from the same manufacturer and confirm it with you before quoting.
What are your payment and shipping terms?
Payment by T/T (bank transfer); payment in your local currency is also supported. Shipping by DHL, UPS or FedEx air express, or by sea freight. Lead time is quoted per inquiry.
Specifications
| ANT411 | Optical ESB bus repeater master module, installed in the FCU (A2FV50, A2FV70, AFV30, AFV40) |
|---|---|
| ANT512 | Optical ESB bus repeater slave module for 5 km to 50 km |
| Pairing | ANT411-0 or -3 with ANB11S-3/-4 or ANB11D-4; ANT411-E or -F with ANB11S-C/-D or ANB11D-D |
| 5 km versions | ANT401 (master) and ANT502 (slave) |
| Node unit power (ANB11) | 100–120 V AC, 220–240 V AC or 24 V DC, by suffix code |
Source: Yokogawa GS 33J60F30-01EN Optical ESB Bus Node Units ANB11S, ANB11D (for N-IO/FIO), 5th edition (July 18, 2019): connection, suffix codes and note *1. Confirm with the manufacturer datasheet before ordering.
Documents
- DatasheetPDF · on request Request
- Operating manualPDF · on request Request
- Certificate copy (with order, where available)PDF · on request Request
Downloads will be added after the files have been checked.
Same series
Other models in the same family as Yokogawa ANT411 / ANT512 DCS I/O.