Overview of Emerson Control Techniques Unidrive SP1405 AC Drives

Unidrive SP Free Standing offers a fully engineered drive that is supplied within a standard sized cabinet.

Free Standing can be ordered with input power equipment to facilitate immediate connection to the power supply and motor.

Unidrive SP Modular offers maximum power system design flexibility. Drive modules can be connected together in a variety of ways to create common DC bus systems, active input systems for returning excess energy to the power supply and parallel drives for high power motors. All drive modules are compact for easy handling

Description of Emerson Control Techniques Unidrive SP1405 AC Drives

SP1405

Servo/Variable Frequency AC Drive – Input Phase 3, Supply Voltage 380/480 V ac, 5 hp Normal Duty, Output Current 8.8 A Normal Duty, IP 20, IP 54 Rating, 48/65 Hz, Closed Loop Vector Control, Open Loop Vector Control, Regenerative Control, Rotor Flux Control, Servo Control, Torque Control, V/Hz Control

The Inverter SP1405 is a 3kW, 7.6A, 380…480V AC variable frequency drive from the Unidrive SP range manufactured by Control Techniques. As an official Control Techniques distributor, Northern Industrial supply the whole range of Unidrive SP variable frequency drives, including options to expand the functionality of the Inverter SP1405 inverter. Control Techniques design all of their inverters to be easy to install and commission, and the Unidrive SP is no different.

High Performance Motor Control  Emerson Control Techniques Unidrive SP1405 AC Drives

The Unidrive SP Inverter SP1405 is capable of controlling induction motors, asynchronous servo and synchronous servo motors thanks to its selection of control modes. By using the keypad, you can configure your variable frequency drive to be operated in the following modes:

Servo – Precision, dynamic control supporting a wide range of rotary and linear motors

Closed Loop Vector – Ultimate precision control of induction motors offering full motor torque at zero speed

RFC Mode (Rotor Flux Control) – Superior dynamic performance and stability without a feedback device

Open Loop Vector – Good open loop motor performance with minimum configuration

Open Loop V/F Control – A simple control algorithm that is ideal for parallel motors

Regenerative – Active front end control mode for harmonic elimination and regeneration

SPECIFICATIONS of Emerson Control Techniques Unidrive SP1405 AC Drives

Drive Type Servo, Variable Frequency

Number of Input Phases 3

Drive Supply Voltage 380/480 V ac

Horsepower Rating Normal Duty 5 hp

Output Current Normal Duty 8.8 A

Operation Mode Open Loop Vector Control, V/Hz Control, Regenerative Control, Servo Control, Rotor Flux Control, Closed Loop Vector Control, Torque Control

Enclosure Rating IP 20, IP 54

Motor Phase 3 ph

Peak Current 13.3 A

Input Frequency Rating 48/65 Hz

Overall Height 368 mm

Overall Depth 219 mm

Overall Dimensions (Height x Width x Depth) 368 x 100 x 219 mm

Overall Width 100 mm

Maximum Ambient Temperature 104 °F

Ambient Temperature Range 32 to 104 °F

Minimum Ambient Temperature 32 °F

Operating Temperature Range +32 to +122 °F

Number of Analog Inputs 3

Number of Digital Inputs 6

Number of Analog Outputs 2

Number of Digital Outputs 3

Feedback Type Incremental Encoder, Absolute Encoder

Standards Met CSA, EN 60529, EN 954-1, IEC 60146-1-1, IEC 61800-5-1, SIL 3, UL

Ordering Codes of Emerson Control Techniques Unidrive SP1405 AC Drives

UNI Drives:   Emerson Control Techniques Unidrive SP1405 AC Drives

We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.