Features
* 2-channel isolated barrier
* 24 V DC supply (Power Rail)
* Input 2-wire SMART transmitters
* Output 0/4 mA … 20 mA
* Terminals with test points
* Up to SIL 2 acc. to IEC 61508
Function of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
* This isolated barrier is used for intrinsic safety applications.
* The device supplies 2-wire SMART transmitters in ahazardous area.
* It transfers the analog input signal to the safe area as anisolated current value.
* Digital signals may be superimposed on the input signal in thehazardous or safe area and are transferred bi-directionally.
* If the HART communication resistance in the loop is too low,the internal resistance of 250 ? between terminals 8, 9and 11, 12 can be used.
* Test sockets for the connection of HART communicators areintegrated into the terminals of the device
Specification of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Input 0/4 mA … 20 mA
Output 0/4 mA … 20 mA
General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage 20 … 35 V DC
Ripple within the supply tolerance
Power dissipation 1.8 W
Power consumption max. 2.7 W
Input of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Connection side field side
Connection terminals 1+, 3-; 4+, 6-
Input signal 0/4 … 20 mA
Available voltage ≥ 16 V at 20 mA, terminals 1+, 3
Output of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Connection side control side
Connection terminals 7-, 8+; 10-, 11+
Load 0 … 550 Ω at 20 mA
Output signal 0/4 … 20 mA (overload > 25 mA)
Ripple max. 50 μA rms
Transfer characteristics
Deviation at 20 °C (68 °F), 0/4 … 20 mA
≤ 10 μA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
Influence of ambient temperature 0.25 μA/K
Frequency range field side into the control side: band width with 1 Vpp signal 0 … 7.5 kHz (-3 dB)
safe area to hazardous area: band width with 1 VSS signal 0.3 … 7.5 kHz (-3 dB)
Settling time 200 μs
Rise time/fall time 20 μs
Galvanic isolation of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Output/power supply functional insulation, rated insulation voltage 50 V AC
Output/Output functional insulation, rated insulation voltage 50 V AC
Indicators/settings of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Display elements LED
Labeling space for labeling at the front
Directive conformity of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Electromagnetic compatibility NE 21:2011
Degree of protection IEC 60529:2001
Protection against electrical shock UL 61010-1:2012
Ambient conditions
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Mechanical specifications of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate BAS 99 ATEX 7025 X
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
Input [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Voltage 25.2 V
Current 93 mA
Power 0.586 W
Supply of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Maximum safe voltage 250 V (Attention! The rated voltage can be lower.)
Certificate TüV 99 ATEX 1499 X
Marking Ex-Hexagon II 3G Ex nA II T4 [device in zone 2]
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
Control drawing 116-0428 (cULus)
IECEx approval IECEx BAS 04.0015X
IECEx CML 15.0055X
Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Ex nA IIC T4 Gc
Ordering Models of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
KFD2-STC5-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KCD2-STC-1.2O
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
KCD2-STC-Ex1.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
KFA6-STR-1.24.4
Power Supply
115/230 V AC supply, Output 24 V DC, 4 A, Fused output, Power Rail connection
KFD0-CS-1.50
Repeater
1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-2.50
Repeater
2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex1.50P
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex1.51P
Current Driver/Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex2.50P
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex2.51P
Current Driver/Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD2-STC3-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 4 mA … 20 mA, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points
KFD2-STC4-Ex2-Y1
SMART Transmitter Power Supply, Output Current Sink
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA … 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-Ex1.2O.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 3 acc. to IEC 61508
KCD2-STC-Ex1.2O.DE
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1.2O.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KCD2-STC-Ex1.ES.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508
KFD0-CS-2.51P
Current Driver/Repeater
2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-SCS-1.55
SMART Current Driver/Repeater
1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD2-HLC-Ex1.D.4S
HART Loop Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 4 relay contact outputs (NO contact), 3 analog outputs 4 mA … 20 mA, Sink and source mode output, Configurable by keypad
KFD2-STC4-Ex1.2O-Y1
SMART Transmitter Power Supply, Output Current Sink
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KFD2-STV4-Ex1-2
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/2 V … 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV4-Ex1.2O-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KFD2-STV4-Ex2-1
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/1 V … 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV4-Ex2-2
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V … 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV5-Ex1-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V … 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KLD2-FBPS-1.12.220
Fieldbus Power Supply
Output: 12 … 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
Ordering Codes of Pepperl+Fuchs KFD2-STC4-Ex2 SMART Transmitter Power Supply
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.