Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Features

*   SMART Transmitter Power Supply KFD2-STC4-Ex1.H

*   1-channel isolated barrier
*   24 V DC supply (Power Rail)
*   Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
*   Output 0/4 mA … 20 mA
*   Terminals with test points
*   High field voltage 17.6 V DC
*   Up to SIL 2 acc. to IEC 61508

Function of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

– This isolated barrier is used for intrinsic safety applications.

– The device supplies 2-wire and 3-wire SMART transmitters with higher output voltage in a hazardous area, and can also be used with 2-wire

SMART current sources.

– It transfers the analog input signal to the safe area as an isolated current value.

– Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.

– If the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.

– Test sockets for the connection of HART communicators are integrated into the terminals of the device.

Technical data of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Product Description of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply
Input 0/4 mA … 20 mA
Output 0/4 mA … 20 mA
General specifications of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply
Signal type Analog input
Functional safety related parameters of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply
Safety Integrity Level (SIL) SIL 2

Supply of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Connection Power Rail or terminals 14+, 15-
Rated voltage 20 … 35 V DC
Ripple within the supply tolerance
Power dissipation 1.5 W
Power consumption 1.9 W

Input of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Connection side field side
Connection terminals 1+, 2-, 3 or 5-, 6+
Input signal 0/4 … 20 mA
Voltage drop ≤ 2.4 V at 20 mA (terminals 5, 6)
Input resistance ≤ 64 Ω terminals 2-, 3 ; ≤ 500 Ω terminals 1+, 3 (250 Ω load)
Available voltage ≥ 17.6 V at 20 mA terminals 1+, 3
Output of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Connection side control side
Connection terminals 7-, 8+, 9
Load 0 … 800 Ω at 20 mA
Output signal 0/4 … 20 mA (overload > 25 mA)
Ripple max. 50 µA rms

Transfer characteristics of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Deviation at 20 °C (68 °F), 0/4 … 20 mA
≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
Influence of ambient temperature 0.25 µA/K
Frequency range field side into the control side: bandwidth with 0.5 Vpp signal 0 … 7.5 kHz (-3 dB)
control side into the field side: bandwidth with 0.5 Vpp signal 0.3 … 7.5 kHz (-3 dB)
Settling time 200 µs
Rise time/fall time 20 µs

Galvanic isolation of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Output/power supply functional insulation, rated insulation voltage 50 V AC

Indicators/settings of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Display elements LED
Labeling space for labeling at the front

Directive conformity of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Conformity of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Electromagnetic compatibility NE 21:2011
Degree of protection IEC 60529:2001
Protection against electrical shock UL 61010-1:2012

Ambient conditions of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Ambient temperature -20 … 60 °C (-4 … 140 °F)

Mechanical specifications of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Degree of protection IP20
Connection screw terminals
Mass approx. 200 g
Dimensions 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

EU-type examination certificate BAS 99 ATEX 7060 X
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
Input [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supply
Maximum safe voltage 250 V (Attention! The rated voltage can be lower.)
Equipment terminals 1+, 3-
Voltage Uo 27.2 V
Current Io 93 mA
Power Po 632 mW
Internal capacitance Ci 12 nF
Internal inductance Li 0 mH
Equipment terminals 2-, 3
Voltage Ui 30 V
Current Ii 117 mA
Voltage Uo 3.5 V
Current Io 73 mA
Power Po 64 mW
Equipment terminals 1+, 2 / 3-
Voltage Uo 27.2 V
Current Io 117 mA
Power Po 639 mW
Internal capacitance Ci 12 nF
Internal inductance Li 0 mH
Equipment terminals 5-, 6+
Voltage Ui 30 V
Current Ii 117 mA
Voltage Uo 8.7 V
Current Io 0 mA
Internal capacitance Ci 0 nF
Internal inductance Li 0 mH
Output
Maximum safe voltage 250 V (Attention! The rated voltage can be lower.)
Certificate TÜV 99 ATEX 1499 X
Marking Ex-Hexagon II 3G Ex nA II T4 [device in zone 2]
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010

International approvals of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

UL approval
Control drawing 116-0428 (cULus)
IECEx approval IECEx BAS 04.0016X
IECEx CML 15.0055X
Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Ex nA IIC T4 Gc

General information of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Similar models of Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply

KFD2-STC5-1
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-1.2O
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
KFD2-STC5-2
SMART Transmitter Power Supply
2-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
KFD2-STC5-Ex1.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, High field voltage 17 V DC, SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-STC5-Ex2
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508

HiC2025
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Low power dissipation, SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2025ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508
HiC2027
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Up to SIL 2 acc. to IEC 61508
HiD2024
SMART Transmitter Power Supply/Current Driver
4-channel isolated barrier, 24 V DC supply (bus powered), Analog in or analog out signals, Sink and source mode outputs, SMART pass-through, Up to SIL 2 acc. to IEC 61508
Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply
KCD2-STC-1.2O
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-STC-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
KCD2-STC-Ex1.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-STC3-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 4 mA … 20 mA, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points
KFD2-STC4-Ex2-Y1
SMART Transmitter Power Supply, Output Current Sink
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA … 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STC5-Ex1.2O.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 3 acc. to IEC 61508
S1SD-1AI-1C.H
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire SMART transmitters and current sources, Output 0/4 mA … 20 mA, Accuracy 0.1 %, Connection via screw terminals
HiC2025A
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Low power dissipation, Reduced intrinsically safe parameters, Up to SIL 2 acc. to IEC 61508
HiC2025HC
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Low power dissipation, Suitable for long field cables (> 1000 m), Up to SIL 2 acc. to IEC 61508
HiC2027DE
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Up to SIL 2 acc. to IEC 61508
HiC2027ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Up to SIL 3 acc. to IEC 61508

KCD2-STC-Ex1.2O.DE
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
KCD2-STC-Ex1.2O.ES
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA or 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KCD2-STC-Ex1.ES.SP
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508
KFD2-STC4-Ex1.2O-Y1
SMART Transmitter Power Supply, Output Current Sink
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, current sink, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KFD2-STV4-Ex1-2
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/2 V … 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV4-Ex1.2O-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/1 V … 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply
KFD2-STV4-Ex2-1
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/1 V … 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV4-Ex2-2
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V … 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV5-Ex1-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V … 5 V, Terminals with test points, SIL 2 (SC 3) acc. to IEC/EN 61508
HiD2022
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (bus powered), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current source, SIL 2 (SC 3) acc. to IEC/EN 61508
HiD2022SK
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (bus powered), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink, Up to SIL 2 acc. to IEC 61508
HiD2030
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA … 20 mA or 1 V … 5 V, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
HiD2030SK
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA … 20 mA, current sink, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508

KCD2-STC-1
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
KFD2-STC4-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STC4-Ex1-Y1
SMART Transmitter Power Supply, Output Current Sink
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
Pepperl+Fuchs KFD2-STC4-Ex1.H SMART Transmitter Power Supply
KFD2-STC4-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
KFD2-STC4-Ex1.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA … 20 mA, Terminals with test points, High field voltage 17.6 V DC, Up to SIL 2 acc. to IEC 61508
KFD2-STC4-Ex2
SMART Transmitter Power Supply
2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA … 20 mA, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KCD2-STC-1.SP
SMART Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA … 20 mA or 1 V … 5 V, Sink or source mode, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
KFD2-STC4-Ex1.2O.H
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA … 20 mA, Terminal blocks with test sockets, High field voltage 17.6 V DC, Up to SIL 3 acc. to IEC 61508
KFD2-STV4-Ex1-1
SMART Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/1 V … 5 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508
KFD2-STV4-Ex1.2O-2
SMART Transmitter Power Supply