Description of MTL838C Fieldbus Networks Multiplexer Receivers

Power management company Eaton has introduced new MTL830 range multiplexers for Zone 0 hazardous area temperature measurement applications, aiming to improve the form factor to minimise hand wiring and simplify installation and maintenance, as well as making them RoHS compliant
The MTL830 range of multiplexers avoids the need to isolate each instrument loop, reducing the cost of installed wiring by up to 50 per cent by communicating the input of multiple hazardous-area temperature sensors over a single twisted pair data highway. Further savings are achieved by reducing the number of inputs to the control system, cabinet space and weight.
MTL831C multiplexer transmitters are normally sited in the hazardous area, typically mounted close to field instruments in an IP65-rated enclosure, supporting thermocouple, RTD and mV analogue sensor inputs. Compatible safe-area MTL838C receivers translate the information transmitted from the MTL831C via the data highway and provide serial Honeywell LLMUX or Modbus outputs, with status information, to feed to host PLC, PC or DCS controllers.

The single data highway cable, a simple twisted pair or pair of wires within an intrinsically safe (IS) multi-core cable, supports communication between the safe and hazardous areas over distances up to one kilometre, and also provides power to the transmitters.
“An important component in hazardous area temperature measurement applications, our MTL830 range multiplexers reduces installation time and costs for intrinsically safe hazardous-area cabling,” said Niaz Ahmed, associate product line manager at Eaton.
“We have invested in the development of the MTL830C multiplexer range to support our large installed base of temperature multiplexers worldwide. This allows migration of MTL830B installations to MTL831C and MTL838C products whilst retaining the same sensors, cabling and control system interface,” Ahmed added.

The multiplexer system aims to communicate the status of up to 32 inputs, reducing the number of hazardous area wiring pairs from 32 to one. This saves installation time and further reduces costs by eliminating long runs of expensive thermocouple compensation cable from the hazardous to the safe area.

The MTL831C Analog Transmitter can transfer a number of hazardous area input signals to the safe area down a data highway consisting of a single shielded, twistedpair cable. It is intrinsically safe and can therefore be mounted in Zone 0 hazardous areas or hazardous locations.

The MTL831C can monitor up to 16 inputs from THC or millivolt sources or 2, 3 or 4-wire RTDs or potentiometers. A data highway is provided that can carry both signal and power over distances up to 2km, depending on the application, the cable and the (noise) environment. Shielded twisted pair is highly recommended. At the other end of the data highway, an MTL838C Receiver translates the information transmitted from the MTL831C. One or two MTL831Cs may be connected to a single MTL838C.

The MTL838C provides a *Modbus® serial data output representation of the inputs together with status information. When the MTL831C transmitter is mounted in the hazardous area, the data highway must be protected by an MTL5553/MTL5053 Isolator/Power Supply mounted in the safe area.
MTL838C Fieldbus Networks Multiplexer Receivers
MTL830 Series multiplexers with Modbus outputs avoid the need to isolate each instrument loop. Reduce the cost of installed wiring by up to 50`% by communicating the status of multiple hazardous-area sensors over dual-redundant data highways.

Features

– Save on the cost of installing hazardous-area cabling
– Reduce installation time, space and weight
– Rapid problem detection with status reporting systems
– Sensor-failure detection and fail safe drive options
– Serial-data outputs to host control system
– AI to Modbus controllers
– Redundant data highway facility
MTL831B – MULTIPLEXER TRANSMITTER
MTL831C Analog Transmitter 
MTL838B-MBF Analogue Multiplexer Receiver
8502-BI-DP Bus Interface Module (BIM)
MTL838C Modbus Implementation
MTL3052 Digital Isolator
MTL838C Fieldbus Networks Multiplexer Receiver
Ordering Models of MTL838C Fieldbus Networks Multiplexer Receivers
MTL838C Fieldbus Networks Multiplexer Receivers
Digital Input     MTL838C Fieldbus Networks Multiplexer Receivers
MTL4501-SR     1ch DI failsafe solid-state output + LFD alarm        
MTL4504          1ch DI relay output + LFD alarm + phase reversal
MTL4510          4ch DI solid-state output        
MTL4510B        4ch DI multifunction solid-state output
MTL4511          1ch DI relay output
MTL4513          2ch DI solid-state output        
MTL4514/B       1ch DI relay output + LFD alarm     
MTL4516          2ch DI relay output
MTL4516C        2ch DI with changeover relay output     
MTL4517          2ch DI relay output + LFD alarm     
Digital Output  MTL838C Fieldbus Networks Multiplexer Receivers
MTL4521          Loop powered solenoid driver
MTL4521L         Loop powered solenoid driver IIC    
MTL4523          Solenoid driver with LFD
MTL4523L         Loop powered solenoid driver + LFD       
MTL4523R         Solenoid driver with LFD
MTL4523V/VL    Solenoid/Alarm driver with voltage control    
MTL4524           Switch operated solenoid driver     
MTL4524S         Switch operated solenoid driver, 24V override       
MTL4525           Switch operated solenoid driver low power   
MTL4526           2ch switch operated relay      
Analogue Input   MTL838C Fieldbus Networks Multiplexer Receivers
MTL4541           1ch 2/3 wire Transmitter repeater
MTL4541A         1ch Transmitter repeater, passive input         
MTL4541AS       1ch Transmitter repeater, passive input, current sink   
MTL4544D          2/3 wire transmitter repeater, dual output   
MTL4544S          2ch 2/3 transmitter repeater, current sink    
Analogue Output  MTL838C Fieldbus Networks Multiplexer Receivers
MTL4546            1ch 4-20mA smart isolating driver + LFD        
MTL4546C          1ch 4-20mA smart isolating driver + oc LFD   
MTL4546Y          1ch 4-20mA smart isolating driver + oc LFD   
MTL4549            2ch 4-20mA smart isolating driver + LFD        
MTL4549C          2ch 4-20mA smart isolating driver + oc LFD   
MTL4549Y          2ch 4-20mA smart isolating driver + oc LFD   
Temperature Input   MTL838C Fieldbus Networks Multiplexer Receivers
MTL4575            1ch Temperature converter with alarm
MTL4576-RTD     2ch Temperature converter, RTD   
MTL4576-THC     2ch Temperature converter, THC   
MTL4581            1ch mV/THC isolator for low-level signals     
Pulse and Vibration   MTL838C Fieldbus Networks Multiplexer Receivers
MTL4531            1ch vibration probe interface
MTL4532            1ch pulse isolator, digital or analogue output         
MTL4533            2ch vibration probe interface
Fire and Smoke   MTL838C Fieldbus Networks Multiplexer Receivers
MTL4561            2ch loop-powered, for fire and smoke detectors  

General               MTL838C Fieldbus Networks Multiplexer Receivers

MTL4599             Dummy isolator      
MTL4599N           General purpose feed-through module
MTL4500 Series Barriers     MTL838C Fieldbus Networks Multiplexer Receivers

MTL838C Fieldbus Networks Multiplexer Receivers
MTL838C Fieldbus Networks Multiplexer Receivers

MTL705+ MTL706+ MTL707+ MTL707P+ MTL708+ MTL710+ MTL710AC MTL710P+ MTL715+ MTL715P+ MTL722+ MTL722P+ 

ICC    MTL838C Fieldbus Networks Multiplexer Receivers

MTL838C Fieldbus Networks Multiplexer Receivers

MTL838C Fieldbus Networks Multiplexer Receivers
MTL838C Fieldbus Networks Multiplexer Receivers
MTL838C Fieldbus Networks Multiplexer Receivers

MTL838C Fieldbus Networks Multiplexer Receivers
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.