Overview of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL 7700 Intrinsically Safe Barrier
DIN-rail zener barriers limit the amount of energy transferred across the barrier to a level that cannot ignite flammable atmospheres
Description of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
The MTL7700 Intrinsically Safe Barriers are 1- or 2-channel DIN-rail mounted shunt-diode safety barriers that use intrinsically safe explosion-protection techniques to pass electrical signals between safe and hazardous areas, while limiting transferred energy to a level that cannot ignite flammable atmospheres. Connected in series with wiring entering any hazardous area on process plant, MTL7700 Series barriers prevent explosions in all normally occurring explosive atmospheres – including mixtures of air with flammable gases, vapors, dusts and fibers – if a fault or faults develop in the safe area.
MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
The MTL7700 is a DIN rail mounting barrier providing quick and easy installation without the need for special hardware. Removable terminals are used for ease of installation, maintenance and for providing a loop disconnect by simply unplugging the terminals from the side of the module. Wire entry is also angled to assist wiring within limited space enclosures. MTL7700 barriers clamp simply and securely onto standard T-section DIN rail, simultaneously making a reliable IS earth connection. For applications where field power is required for switch inputs or 2-wire transmitters, the MTL7700 range provides a bussed power feed facility. When used in conjunction with the MTL7798 power feed module the user has a fully protected, electronically fused supply to many barriers with no additional wiring required.
MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
All MTL7700 Series barriers are based on the same simple principle. Each channel contains two stages of pulse-tested Zener or forward connected diodes and an ‘infallible’ terminating resistor. In the event of an electrical fault in the safe area, the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes, and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output current limiting circuits are employed. All models (except MTL7707P+ and MTL7729P+, ‘ia’ ‘IIB’) are certified ‘ia’ for all zones and ‘IIC’ for all explosive atmospheres.
MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
STRAIN-GAUGE BRIDGES
Single strain-gauge bridges
This shows an arrangement using two or three barriers, which is safe in IIC gases. With the MTL7761ac, the circuit is powered from a 14V, 230Ω source; if the bridge resistance is 230Ω, then the bridge voltage is 7V. If the bridge resistance is 350Ω, then the bridge voltage is 8.4V.
An MTL7764ac can be used to sense the bridge supply voltage.
An MTL7761ac is used here for the mV output.
An MTL7766Pac provides 12.3V for a 350Ω bridge with a 20V supply.
MTL7761Pac’s can be used for the sense and pick-off circuits.
Features
* Removable terminals for easy cabling
* Bussed power feed to other modules
* Relay and solid state switch modules
* Dual channel variants: 6.3mm per channel
* Barrier protection module
* Proximity detector inputs
* Electronic fusing
* Direct replacement for MTL700 Series barriers
* Compatible terminal numbering and safety descriptions
Application of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
Here’s how some of our customers use this product…
Protecting Sensor Circuits in a Hazardous Location
The Background: Our customer is a ceramics manufacturer seeking a means to protect sensor circuits in a hazardous area location.
The Problem: The customer utilizes methanol during the annealing process. As a highly flammable substance, the storage area for the methanol is classified as a hazardous area. As such, they must have intrinsically safe barriers for all sensor circuits that pass into the methanol storage area.
The Solution: We recommended MTL7700 Intrinsically Safe Barriers. The 7700 is a shunt-diode barrier that limits the amount of energy allowed to pass between safe and hazardous areas to a level that cannot ignite flammable atmospheres. They are DIN-rail mounted which provides quick and easy installation without the need for special hardware.
PRODUCT LITERATURE of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
Product Code Description of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
intrinsically safe logo Symbol denotes that the equipment is suitable for use in hazardous area applications.
fsm logo Symbol denotes that the product has been assessed for functional safety applications.
SM45-55-AI SM45-55-AI is FSM FSM Safety Manual – Analogue Input Modules
SM45-55-AO SM45-55-AO is FSM FSM Safety Manual – Analogue Output Modules
SM45-55-BI SM45-55-BI is FSM FSM Safety Manual – Binary Input Modules
SM45-55-MMI SM45-55-MMI is FSM FSM Safety Manual – Machine Monitor Interfaces
SM45-55-SAD SM45-55-SAD is FSM FSM Safety Manual – Solenoid / Alarm Driver Modules
1. Intro of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4501-SR MTL4501-SR is intrinsically safe MTL4501-SR is FSM 1ch DI failsafe solid-state output + LFD alarm
MTL4504 MTL4504 is intrinsically safe MTL4504 is FSM 1ch DI relay output + LFD alarm + phase reversal
MTL4510 MTL4510 is intrinsically safe 4ch DI solid-state output
MTL4510B MTL4510B is intrinsically safe 4ch DI multifunction solid-state output
MTL4511 MTL4511 is intrinsically safe MTL4511 is FSM 1ch DI relay output
MTL4513 MTL4513 is intrinsically safe 2ch DI solid-state output
MTL4514D MTL4514D is intrinsically safe MTL4514D is FSM 1ch switch/prox input, dual output relay
MTL4514_B MTL4514_B is intrinsically safe MTL4514_B is FSM 1ch DI relay output + LFD alarm
MTL4516 MTL4516 is intrinsically safe MTL4516 is FSM 2ch DI relay output
MTL4516C MTL4516C is intrinsically safe MTL4516C is FSM 2ch DI with changeover relay output
MTL4517 MTL4517 is intrinsically safe MTL4517 is FSM 2ch DI relay output + LFD alarm
3. Digital Output of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4525 MTL4525 is intrinsically safe MTL4525 is FSM Switch operated solenoid driver low power
MTL4526 MTL4526 is intrinsically safe 2ch switch operated relay
4. Analogue Input of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4541 MTL4541 is intrinsically safe MTL4541 is FSM 1ch 2/3 wire Transmitter repeater
MTL4541A MTL4541A is intrinsically safe 1ch Transmitter repeater, passive input
MTL4541AS MTL4541AS is intrinsically safe 1ch Transmitter repeater, passive input, current sink
MTL4541T MTL4541T is intrinsically safe 2/3 wire Transmitter repeater
MTL4544 MTL4544 is intrinsically safe MTL4544 is FSM 2ch 2/3 wire Transmitter repeater
MTL4544A MTL4544A is intrinsically safe 2ch Transmitter repeater, passive input
MTL4544AS MTL4544AS is intrinsically safe 2ch Transmitter repeater, passive input, current sink
MTL4544B MTL4544B is intrinsically safe MTL4044 replacement
MTL4544D MTL4544D is intrinsically safe MTL4544D is FSM 2/3 wire transmitter repeater, dual output
MTL4544S MTL4544S is intrinsically safe MTL4544S is FSM 2ch 2/3 transmitter repeater, current sink
5. Analogue Output of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4546 MTL4546 is intrinsically safe MTL4546 is FSM 1ch 4-20mA smart isolating driver + LFD
MTL4546C MTL4546C is intrinsically safe MTL4546C is FSM 1ch 4-20mA smart isolating driver + oc LFD
MTL4546S MTL4546S is intrinsically safe 1ch 4-20mA HART isolating driver + LFD
MTL4546Y MTL4546Y is intrinsically safe MTL4546Y is FSM 1ch 4-20mA smart isolating driver + oc LFD
MTL4549 MTL4549 is intrinsically safe MTL4549 is FSM 2ch 4-20mA smart isolating driver + LFD
MTL4549C MTL4549C is intrinsically safe MTL4549C is FSM 2ch 4-20mA smart isolating driver + oc LFD
MTL4549Y MTL4549Y is intrinsically safe MTL4549Y is FSM 2ch 4-20mA smart isolating driver + oc LFD
6. Temperature Input of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4573 MTL4573 is intrinsically safe 1ch Temperature converter, RTD / THC
MTL4575 MTL4575 is intrinsically safe 1ch Temperature converter, RTD / THC with alarm
MTL4576-RTD MTL4576-RTD is intrinsically safe 2ch Temperature converter, RTD
MTL4576-THC MTL4576-THC is intrinsically safe 2ch Temperature converter, THC
MTL4581 MTL4581 is intrinsically safe 1ch mV/THC isolator for low-level signals
MTL4582B MTL4582B is intrinsically safe MTL4582B is FSM 1ch resistance isolator to repeat RTD signals
7. Pulse and Vibration of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4531 MTL4531 is intrinsically safe MTL4531 is FSM 1ch vibration probe interface
MTL4532 MTL4532 is intrinsically safe 1ch pulse isolator, digital or analogue output
8. Fire and Smoke of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4561 MTL4561 is intrinsically safe MTL4561 is FSM 2ch loop-powered, for fire and smoke detectors
9. General of MTL7761PAC MTL7728P+ Shunt Diode Safety Barriers
MTL4599 Dummy isolator
MTL4599N General purpose feed-through module