Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Features of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

HART Multiplexer Master KFD2-HMM-16

16-channel
24 V DC supply (Power Rail)
HART field device input (revision 5 to 7)
Up to 15 KFD0-HMS-16 slave units can be connected
Up to SIL 3 acc. to IEC 61508

Technical Specification of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Product Description of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

HART Multiplexer Master
Functional safety related parameters of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Safety Integrity Level (SIL) SIL 3

Supply of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Connection terminals 17+, 18-
Rated voltage 20 … 32 V DC typical at 100 mA
Power consumption max. 3 W

HART signal channels (non-intrinsically safe) of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Conformity HART field device input (revision 5 to 7)
Connection 26-pin flat cable for analog connections
14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16
Leakage current < 3 µA at -20 … 85 °C (-4 … 185 °F)
Terminating resistor external 230 … 500 Ω standard (up to 1000 Ω possible)
Output voltage ≥ 400 mV ss (with the terminator resistance specified above)
Output resistance 100 Ω or smaller, capacitive coupling
Input impedance according to HART specification
Input voltage range 0.08 … 4 V ss ; typ. ± 5.2 V as local reference

Interface of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Transfer rate 9600, 19200, or 38400 Bit/s (selectable with DIL switch (2 and 3) by the user)
Type RS-485 , 2-wire multidrop
Address selection One of 31 possible addresses selectable per DIL switch (4 … 8)

Indicators/settings of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Control elements DIP-switch
Configuration via DIP switches
Labeling space for labeling at the front

Directive conformity of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Degree of protection IEC 60529:2001

Ambient conditions of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Ambient temperature -20 … 60 °C (-4 … 140 °F)

Mechanical specifications of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Degree of protection IP20
Mass approx. 250 g
Dimensions 40 x 107 x 115 mm (1.6 x 4.2 x 4.5 inch) , housing type C1
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Certificate PF 07 CERT 1143 X
Marking Ex-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-15:2010

General information of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master

System Classcode
ECLASS 11.0 27210190
ECLASS 10.0.1 27210190
ECLASS 9.0 27210190
ECLASS 8.0 27210190
ECLASS 5.1 27242692
ETIM 8.0 EC001601
ETIM 7.0 EC001601
ETIM 6.0 EC001601
UNSPSC 12.1 39121008
Similar models of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master
HiDMux2700
HART Multiplexer Master
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC 61508
KFD2-HMM-16
HART Multiplexer Master
16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508
Ordering Codes of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master
Ordering Models of Pepperl+Fuchs KFD2-HMM-16 HART Multiplexer Master