Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Product Features of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Transmitter Power Supply/Converter KFU8-VCR-1

1-channel signal conditioner
Universal usage at different power supplies
Input 2-wire and 3-wire transmitters, current and voltage sources
Current and voltage output
Technical Specification of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters
General specifications
Signal type Analog input
Supply of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Connection terminals 14, 15
Rated voltage 19 … 90 V DC / 48 … 253 V AC
Rated current ≤ 110 mA DC / ≤ 75 mA AC
Power dissipation 1.3 W
Power consumption 2.1 W

Input of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Connection side field side
Input I
Connection terminals 1+, 2-, 3
Input signal 0/4 … 20 mA
Rated current 22 mA
Available voltage > 15 V at 20 mA , terminals 1+, 3-
Open circuit voltage/short-circuit current 21 V / 26 mA , terminals 1+, 3-
terminals 1+, 2- not short-circuit protected
Input resistance < 55 Ω , terminals 2-, 3+
Input II
Connection terminals 5-, 6+
Input signal 0/2 … 10 V
Input resistance > 1 MΩ

Output of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Connection side control side
Output I current output
Connection source: terminals 7(-), 8(+)
sink: terminals 7(+), 9(-)
Output signal 0/4 … 20 mA
Source load 0 … 750 Ω open circuit voltage < 21 V
Sink voltage across terminals 5 … 30 V
Output II voltage output
Connection terminals 10-, 11+
Output signal 0/2 … 10 V
Load min. 10 kΩ

Transfer characteristics of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Deviation
Resolution/accuracy S1 in position I: 7 µA/40 µA (0.2 %)
S1 in position II: 3.5 mV/20 mV (0.2 %)
Influence of ambient temperature 0.01 % / K of output signal range
Reaction time 150 ms

Galvanic isolation of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Input/Output functional insulation acc. to IEC 62103, rated insulation voltage 100 Vrms
Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Display elements LED
Control elements DIP-switch
rotary switch
Configuration via DIP switches
via rotary switch
Labeling space for labeling at the front

Directive conformity of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010

Conformity of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:1989+A1:1999+A2:2013
Ambient conditions
Ambient temperature -20 … 60 °C (-4 … 140 °F)

Mechanical specifications of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

General information of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

System Classcode
ECLASS 11.0 27210119
ECLASS 10.0.1 27210119
ECLASS 9.0 27210119
ECLASS 8.0 27210119
ECLASS 5.1 27210119
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 32101514

Similar Models of Pepperl+Fuchs KFU8-VCR-1 Transmitters Power Supply/Converters

KFD2-CRG2-1.D
Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-CRG2-Ex1.D
Transmitter Power Supply
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFU8-CRG2-1.D
Transmitter Power Supply
1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFU8-CRG2-Ex1.D
Transmitter Power Supply
1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA … 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFU8-VCR-1
Transmitter Power Supply/Converter
1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output
S1SD-1AI-1U
Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire transmitters and 2-wire current sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals
S1SD-1AI-2C
Transmitter Power Supply/Signal Splitter
1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Dual output 0/4 mA … 20 mA, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals
FB3204B2
Transmitter Power Supply, Input Isolator
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
LB3104A2
Transmitter Power Supply, Input Isolator
4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA … 20 mA