Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Features

SMART Current Driver/Repeater KFD0-SCS-Ex1.55

1-channel isolated barrier
24 V DC supply (loop powered)
Current input/output 4 mA … 20 mA
HART I/P or transmitter power supply
Low voltage drop
Line fault detection (LFD)
Up to SIL 2 acc. to IEC/EN 61508
Technical data of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

General specifications of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Signal type Analog input/analog output

Functional safety related parameters of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Safety Integrity Level (SIL) SIL 2

Supply of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Rated voltage loop powered
Power dissipation 0.2 W

Control circuit of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Connection terminals 8-, 9+
Voltage max. 30 V DC
Current 4 … 20 mA (quiescent current < 0.5 mA)
Power dissipation 150 mW at 20 mA and Uin < 24 V

Field circuit of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Connection terminals 1+, 2 / 3-
Voltage ≥ 16 V for supply voltage > 21 V
Current 4 … 20 mA (linear transmission 1 … 22 mA)
Load ≤ 800 Ω (at 20 mA)

Transfer characteristics of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Voltage drop see note

Deviation of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

After calibration ≤ ± 80 µA linearity, load and voltage dependence at 20 °C (68 °F)
Influence of ambient temperature < 0.5 µA/K
Damping approx. 3 dB
Rise time ≤ 20 µs at 0 Ω, ≤ 600 µs with 800 Ω load

Galvanic isolation of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

Indicators/settings of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Labeling space for labeling at the front

Directive conformity of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Conformity of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Electromagnetic compatibility NE 21:2007
Degree of protection IEC 60529:2001

Ambient conditions of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Ambient temperature -20 … 60 °C (-4 … 140 °F)

Mechanical specifications of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Degree of protection IP20
Connection screw terminals
Mass approx. 120 g
Dimensions 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) (W x H x D) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

EU-type examination certificate PTB 02 ATEX 2064
Marking Ex-Hexagon II (2)G [EEx ib] IIC
Voltage 23.1 V DC
Current 28 mA
Power 0.647 W
Supply
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Certificate PF 11 CERT 0902 X
Marking Ex-Hexagon II 3G Ex nA IIC T4 Gc
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010

International approvals of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

FM approval device with FM approval on request

General information of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

System Classcode
ECLASS 11.0 27210120
ECLASS 10.0.1 27210120
ECLASS 9.0 27210120
ECLASS 8.0 27210120
ECLASS 5.1 27210120
ETIM 8.0 EC002653
ETIM 7.0 EC002653
ETIM 6.0 EC002653
ETIM 5.0 EC001485
UNSPSC 12.1 32101514

Similar Models of Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters

KCD2-RR2-Ex1 Resistance Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 … 30 V DC, Field device: resistance thermometer, Signal: Resistance, Line fault detection
KFD0-CS-Ex1.51P Current Driver/Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field / to the control system, Reverse polarity protection, Safety Integrity Level (SIL): SIL 2, Rated voltage: loop powered, Signal: 1 x 0 … 40 mA, Device: 1 x fire alarm, Signal: 1 x 0 … 40 mA
KFD0-CS-Ex1.54 Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: loop powered, Signal: 1 x 1 … 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 … 20 mA
KFD0-CS-Ex2.52 Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the control system, Rated voltage: loop powered, Signal: 2 x 4 … 20 mA, Signal: 2 x 4 … 20 mA
KFD0-SCS-Ex1.55 SMART Current Driver/Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field / to the control system, HART communication, Safety Integrity Level (SIL): SIL 2, Rated voltage: loop powered, Signal: 1 x 4 … 20 mA, Signal [2]: 1 x HART, Signal: 1 x 4 … 20 mA, Line fault detection
KFD2-VR-Ex1.18 Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V … 12 V, Voltage output 0 V … 12 V, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 20 … 35 V DC, Signal: 1 x 0 … 12 V, Signal: 1 x 0 … 12 V, Cut-off frequency: 1.2 kHz (-3 dB)
KFD2-VR-Ex1.19 Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V … 10 V, Voltage output -10 V … 10 V, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 20 … 35 V DC, Signal: 1 x -10 … 10 V, Signal: 1 x -10 … 10 V, Cut-off frequency: 1.2 kHz (-3 dB)
KFD2-VR2-Ex1.50M Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV … ± 50 mV, Voltage output 0 mV … ± 50 mV, Selectable up/downscale sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 19 … 30 V DC, Signal: 1 x -50 … 50 mV, Signal: 1 x -50 … 50 mV, Cut-off frequency: 350 Hz (-3 dB)
KFD2-VR4-Ex1.26 Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V … -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V … -20 V, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 … 30 V DC, Signal: 1 x -20 … 0 V, Signal: 1 x -20 … 0 V, Cut-off frequency: 10 kHz (-0,1 dB) 
20 kHz (-1 dB)
KFD0-CS-Ex1.50P Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field / to the control system, Reverse polarity protection, Safety Integrity Level (SIL): SIL 2, Rated voltage: loop powered, Signal: 1 x 4 … 20 mA, Device: 1 x fire alarm, Signal: 1 x 4 … 20 mA
Pepperl+Fuchs KFD0-SCS-Ex1.55 SMART Current Drivers/Repeaters
KFD0-CS-Ex1.54-Y2 Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Rated voltage: loop powered, Signal: 1 x 1 … 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 … 20 mA
KFD0-CS-Ex2.50P Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field / to the control system, Reverse polarity protection, Safety Integrity Level (SIL): SIL 2, Rated voltage: loop powered, Signal: 2 x 4 … 20 mA, Device: 2 x fire alarm, Signal: 2 x 4 … 20 mA
KFD0-CS-Ex2.51P Current Driver/Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field / to the control system, Reverse polarity protection, Safety Integrity Level (SIL): SIL 2, Rated voltage: loop powered, Signal: 2 x 0 … 40 mA, Device: 2 x fire alarm, Signal: 2 x 0 … 40 mA
KFD0-CS-Ex2.54 Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: loop powered, Signal: 2 x 1 … 20 mA, Signal [2]: 2 x HART, Device: 2 x fire alarm, Signal: 2 x 1 … 20 mA
KCD2-RR2-Ex1.SP Resistance Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 … 30 V DC, Field device: resistance thermometer
KFD0-CS-Ex1.52 Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: loop powered, Signal: 1 x 4 … 20 mA, Signal: 1 x 4 … 20 mA
KFD2-VR-Ex1.12 Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V … 9 V, Voltage output 0 V … 9 V, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 20 … 35 V DC, Signal: 1 x 0 … 9 V, Signal: 1 x 0 … 9 V, Cut-off frequency: 1.2 kHz (-3 dB)
KFD2-VR-Ex1.19-Y109129 Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V … 10 V, Transmission frequency up to 50 kHz, Voltage output -10 V … 10 V, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 20 … 35 V DC, Signal: 1 x -10 … 10 V, Signal: 1 x -10 … 10 V, Cut-off frequency: 50 kHz (-3 dB)
KFD2-VR2-Ex1.500M Voltage Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV … ± 500 mV, Voltage output 0 mV … ± 500 mV, Selectable up/downscale sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 19 … 30 V DC, Signal: 1 x -500 … 500 mV, Signal: 1 x -500 … 500 mV, Cut-off frequency: 350 Hz (-3 dB)
KFD2-FF-Ex2.RS232 RS 232 Repeater
1-channel isolated barrier, 24 V DC supply (Power Rail), RS 232 input/output, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 19 … 30 V DC, Interface: RS 232, Interface: RS 232