Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Product Features of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Sensor output interface terminal KCD2-R
Relay output with 1 pole, yellow LED indicates switching state
Free-wheeling diode
Compact terminal housing
Clips onto standard 35 mm rail to DIN EN 50 022
Degree of protection IP20
Technical data of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Product Description of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Sensor output interface terminals with relay output
Functional safety related parameters of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
MTTFd 19699 a
Indicators/operating means of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
LED yellow switch output
Electrical specifications of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Operating voltage 24 V DC ± 15 %
Ripple ≤ 10 %
Operating current 16 mA
Input of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Connection terminals 2+, 3-
Connectable sensor typ es PNP or NPN 3-wire sensors
Output of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Switching frequency ≤ 10 Hz
Relay 1 changeover contact
Contact loading 30 V DC/2 A resistive load
Delay Pull-in: approx. 6 ms
Drop-out: approx. 2 ms
Mechanical life ≥108 switching cycles
Directive conformity of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013
Standard conformity of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Degree of protection EN 60529:2000
Noise immunity EN 61326-1:2013
Ambient conditions of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Ambient temperature -25 … 60 °C (-13 … 140 °F)
Storage temperature -25 … 85 °C (-13 … 185 °F)
Mechanical specifications of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
Degree of protection IP20
Connection self-opening apparatus connection terminals,
max. core cross-section 0.34 … 2.5 mm2
Mass 60 g
Dimensions 20 mm x 60 mm x 40 mm
Classifications of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
System Classcode
ECLASS 11.0 27210121
ECLASS 10.0.1 27210121
ECLASS 9.0 27210121
ECLASS 8.0 27210121
ECLASS 5.1 27210121
ETIM 8.0 EC002653
ETIM 7.0 EC002653
ETIM 6.0 EC002653
ETIM 5.0 EC002653
UNSPSC 12.1 41111902
Similar Models of Pepperl+Fuchs KCD2-R Sensor Output Interface Terminal
KCD2-E2L
Sensor output interface terminal
Single-channel terminal amplifier with line breakage detection, input for NAMUR sensors, DC 24 V supply voltage, standardized interface to prevent signal transmission errors, switching state display, LED yellow
KCD2-R
Sensor output interface terminal
Relay output with 1 pole, yellow LED indicates switching state, Free-wheeling diode, Compact terminal housing, Clips onto standard 35 mm rail to DIN EN 50 022, Degree of protection IP20
KFU8-FSSP-1.D
Frequency voltage current converter
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 … 9999), Multi-range power pack, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable, Rated voltage: 200 … 230 V AC ; 100 … 130 V AC; 50 Hz
20 VDC … 30 VDC
K23-SSI/USB/25B-C
Signal Converter
Multifunction device with operating modes for incremental rotary encoders, SSI absolute rotary encoders, and rotary encoders with start/stop interface, USB interface for configuring and reading, Extremely short conversion times, User-definable, non-linear characteristic curve with 24 interpolation points, Auxiliary voltage output 5 V DC and 24 V DC for rotary encoder supply, Operating voltage: 10 … 30 V DC, Input type: Incremental, Input format: RS422, TTL, HTL differential, HTL PNP, or HTL NPN
KCD2-E1
Sensor output interface terminal
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LED
KCD2-E3
Sensor output interface terminal
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LED
KCD2-EL
Sensor output interface terminal
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LED
K23-SSI/Rx/IU-C
Signal Converter
Multifunction device with operating modes for incremental rotary encoders, SSI absolute rotary encoders, and rotary encoders with start/stop interface, 16 bit analog output, configurable for voltage or current operations, USB interface and RS232/RS485 interface for configuration and readout, Extremely short conversion times, User-definable, non-linear characteristic curve with 24 interpolation points, Operating voltage: 18 … 30 V DC, Input type: Incremental
KFU8-UFC-1.D.FA
Frequency Converter with Trip Values
1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz … 10 kHz, Current output 0/4 mA … 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring
KFU8-FSSP-1.D-Y322444
Frequency voltage current converter
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 … 9999), 2-, 3-, 4-wire sensors and rotary encoder can be connected, Auxiliary power output for sensors, Rated voltage: 20 … 30 V DC
KFU8-UFT-2.D.FA
Frequency Converter with Direction and Synchronization Monitor
2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz … 1 kHz, Current output 0/4 mA … 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Rated voltage: 20 … 90 V DC / 48 … 253 V AC 50 … 60 Hz, Input I, II: 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact, Output I, II: signal, relay, Output V: analog
KFU8-FSSP-1.D-Y180599
Frequency voltage current converter
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 … 9999), 2-, 3-, 4-wire sensors and rotary encoder can be connected, Auxiliary power output for sensors, Rated voltage: 20 … 30 V DC