Feature:
Flow monitor SI5002 SID10ADBFPKG/US-100
Reliable monitoring of liquids and gases in pipes
Variable process connection using adapters
Easy setting of the switch points for quick set-up
Robust stainless steel housing for use in harsh industrial environments
LED bar graph for indication of switch point and flow
Product characteristics:
Number of inputs and outputsNumber of digital outputs: 2
Process connectionthreaded connection M18 x 1,5 Internal thread
Application
MediaLiquids; Gases
Medium temperature[°C]-25…80
Pressure rating
300 bar30 MPa
Liquids
Medium temperature[°C]-25…80
Gases
Medium temperature[°C]-25…80
Electrical data
Operating voltage[V]18…36 DC
Current consumption[mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC[V]2.5
Permanent current rating of switching output DC[mA]250
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Measuring/setting range
Probe length L[mm]45
Liquids
Setting range[cm/s]3…300
Greatest sensitivity[cm/s]3…100
Gases
Setting range[cm/s]200…3000
Greatest sensitivity[cm/s]200…800
Accuracy / deviations
Repeatability[cm/s]1…5
Note on repeatability
for water 5…100 cm/s; 25 °C
Factory setting
Temperature drift[cm/s x 1/K]0.1; (for water 5…100 cm/s; 10…70 °C)
Max. temperature gradient of medium[K/min]300
Switch point accuracy[cm/s]± 2…± 10; (for water 5…100 cm/s; 25 °C; Factory setting)
Hysteresis[cm/s]2…5; (for water 5…100 cm/s; 25 °C; Factory setting)
Reaction times
Response time[s]1…10
Liquids
Response time[s]1…10
Gases
Response time[s]1…10
Software / programming
Adjustment of the switch pointpushbuttons
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor: Process Data Variable; Device Identification
SIO modeyes
Required master port classA
Process data analog2
Process data binary2
Min. process cycle time[ms]3
Supported DeviceIDs
Type of operationDeviceID
default51
Operating conditions
Ambient temperature[°C]-25…80
Storage temperature[°C]-25…100
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Shock resistance
DIN IEC 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (55…2000 Hz)
MTTF[years]277
Mechanical data
Weight[g]247.5
Housingtubular
Dimensions[mm]Ø 50 / L = 113
Materialstainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X
Materials (wetted parts)stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Process connectionthreaded connection M18 x 1,5 Internal thread
Probe diameter[mm]8.2
Installation length EL[mm]45
Displays / operating elements
Display
Function10 x LED, three-color
Remarks
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.