Description of ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

TTH300 Head-mount temperature transmitter

The two-channel temperature transmitter TTH300 with HART, PROFIBUS PA or FOUNDATION Fieldbus in two-wire technology has extensive functions and diagnostic options for all applications. For the new TTH300 HART, these have been expanded once again and the user-friendliness has been further improved.

Overview of ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

The TTH300 is provided for the highest requirements of temperature measurement with two sensor inputs. This supports sensor redundancy and sensor drift monitoring. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. As an option, an LCD indicator with operating buttons can be connected.

The TTH300 HART can be configured with ABB-tools such as Field Information Manager (FIM), with DAT200 (Asset Vision Basic) via DTM, with a Handheld via EDD, or with any standard tool using FDI-/FDT-Technology.

Transmitter with PROFIBUS PA can be configured via GSD file, EDD or DTM, with FOUNDATION Fieldbus via EDD/CF. 

Data of ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

*  Two universal sensor inputs, each for RTD, thermocouple, Ω, mV
*  Functional safety SIL 2 / SIL 3 in accordance with IEC 61508 (HART variant)
*  Various sensor error-calibration possibilities
– One point, two point, Callendar-van-Dusen, freestyle characteristics with 32 supporting points
*  Sensor backup / automatic sensor redundancy switching (2 x Pt100 3-wire connection and further sensor combinations)
*  Redundancy behavior configurable for increased availability, increased safety or increased accuracy (HART variant)
*  Output signal
– 4 to 20 mA, HART 5 and HART 7 (switchable)
– PROFIBUS PA 3.01
– FOUNDATION Fieldbus ITK 5.x
*  Accuracy 0.1 %, long-term stability 0.05 % per year
*  Wire break / corrosion monitoring in accordance with NE 89
*  Device status signaling and freely configurable diagnostic categorization with diagnostic history according to NE 107 (HART variant)
*  Event monitor for logging critical events (HART variant)
*  Configuration monitor for configuration changes (HART variant)
*  Turnable LCD indicator with operating buttons (option)
*  Approvals for explosion protection
– ATEX, IECEx, zone 0
– FM / CSA
– EAC, EAC-Ex

– NEPSI

Specification of ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

CE Marking  The device fulfills all requirements for CE marking in accordance with all applicable guidelines.
Electrical isolation  3.5 kV DC (approx. 2.5 kV AC), 60 s, input to output
Input filter  50 / 60 Hz
ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

Switch-on delay
• HART: < 10 s (Ia ≤ 3.6 mA during switch-on cycle)
• PROFIBUS: 10 s, max. 30 s
• FOUNDATION Fieldbus: < 10 s
Warm-up time    5 minutes

Rise time t90   400 to 1000 ms

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

Measured value update
10/s with 1 sensor, 5/s with 2 sensors, depending on sensor type and sensor circuit
Output filter  Digital filter 1 order: 0 to 100 s
Weight  50 g
ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters
Material
• Housing: polycarbonate
• Color: gray RAL9002

• Casting material: polyurethane (PUR), WEVO PU-417 

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

Installation conditions
• Mounting position: no restrictions
• Installation options:
 Connection heads in accordance with DIN 43729 form B
 Rail mounting (35 mm) in accordance with EN 60175 by means of latching base

 Field mount housing 

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

Electrical connection
• Terminals with captive stainless steel screws, including soldering tags
• Lines up to a maximum of 1.5 mm2 (AWG 16)

• Connection for handheld terminal 

Ambient conditions
Ambient temperature
• Default: −40 to 85 °C (−40 to 185 °F)
• Optional: −50 to 85 °C (−58 to 185 °F)
• Restricted range during operation with LCD-indicator: −20 to 70 °C (−4 to 158 °F)
• Restricted range during operation with explosion-proof design: see corresponding certificate
Transport- / Storage temperature    −50 to 85 °C (−58 to 185 °F)
Climate class in accordance with DIN EN 60654-1
Cx −40 to 85 °C (−40 to 185 °F) at 5 to 95 % relative air humidity 

Ordering Models of ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

TTH300.E1.H.BF
TTH300E1HBS
TTH300.Y0.H.BF
TTH300.Y0.H.BS
TTH300.E1.H.BS
TTH300E1.H.BS.D4.M5
ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

ABB TTH300-E1-H-BS-M5
ABB TTH300.E1.H.BS
ABB TTH300.E1.H.BF
TTH300-E1-H-BS
TTH300-E1H
TTH300-Y0-H-BS-M
TTH300-E1-H-BS-M

TTH300-E2-H-BS-M

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

ABB TB556.J.1.D.15.T.30
ABB TB556.J.1.E.15.T.30
ABB TB556.J.3.E.11.T.20
ABB TB567.J.3.B.0.8.T.30

ABB TB557.1.1.D.B.1.T.20

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

ABB TTH200.E1.H.BS
ABB TTH200.E1.H.BS.C6.EM.GHA.M5-C6GHE
ABB TTH200.E1.H.BS.C6.EM.GHA.M5
ABB TTH200-S1
ABB TTH200
ABB TTR200

ABB TTF200

266DSH DIFFERENTIAL PRESSURE TRANSMITTER (FOR MEASURING DIFFERENTIAL PRESSURE)
266HRH GAUGE TRANSMITTER WITH REMOTE SEAL 266HRHVRGA1/E6/L1/B7(FOR MEASURING GUAGE PRESSURE)
266HRH GAUGE TRANSMITTER WITH REMOTE SEAL 266HRHVRGA1/E6/L1(FOR MEASURING GUAGE PRESSURE)
266HRH GAUGE TRANSMITTER WITH REMOTE SEAL 266HRHVRRA1/E6/L1/B7(FOR MEASURING GUAGE PRESSURE)

266HSH GAUGE PRESSURE TRANSMITTERABA2/VA/L1/B6/P1(FOR MEASURING THE PRESSURE OF LIQUID)

AC212-231261/ STD
AX410-100010/ S

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

MS116-6.3 RANGE 4-6.3A
MS116-1.0  RANG 0.63-1.0A
MS116-0.63 RANGE 0.4-0.63A
MS165-42

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

Model No Example
ACS-CP-C

SB822

ACS880-01-04A0-3

ACS-CP-C
Other related product for ABB temperaturer series product as below.
ABB SensyTemp TSC400 industrial thermometers
ABB SensyTemp TSC420 industrial thermometers
ABB SensyTemp TSC430 industrial thermometers
ABB TTF300 Field-mount temperature transmitter
ABB TTF300-W WirelessHART temperature transmitter
ABB TTH200 Head-mount temperature transmitter
ABB TTH300 Head-mount temperature transmitter
ABB SensyTemp TSH200 High temperature thermometer
ABB TSH210 High temperature thermometer
ABB TSH220 High temperature thermometer
ABB TSH250 High temperature thermometer
ABB TSM800 Multipoint temperature sensor
ABB SensyTemp TSP100 Temperature sensor
ABB SensyTemp TSP111 Temperature sensor
ABB SensyTemp TSP121 Temperature sensor
ABB SensyTemp TSP131 Temperature sensor
ABB SensyTemp TSP300 Temperature sensor
ABB SensyTemp TSP311 Temperature sensor
ABB SensyTemp TSP321 Temperature sensor
ABB SensyTemp TSP331 Temperature sensor
ABB TSP300-W WirelessHART temperature sensor
ABB TSP311-W WirelessHART temperature sensor
ABB TSP321-W WirelessHART temperature sensor
ABB TSP331-W WirelessHART temperature sensor
ABB TSP341-W WirelessHART temperature sensor
ABB SensyTemp TSP411 Temperature sensor
ABB TTR200 Rail-mount temperature transmitter
ABB SensyTemp TSHY Sanitary application thermometer

ABB TSW400 Thermowell

Absolute pressure transmitter 261AS
Absolute pressure transmitter with remote diaphragm seal 266ART
Absolute pressure transmitter 266AST
High overload absolute pressure transmitter with remote diaphragm seal 266NRH
High overload absolute pressure transmitter 266NSH
Absolute pressure transmitter DP-style with remote diaphragm Seal 266RRT
Absolute pressure transmitter DP-Style 266RST
Differential pressure transmitter with remote diaphragm seal 266DRH
Differential pressure transmitter DP-Style 266DSH
Differential pressure transmitter with remote diaphragm seals and multisensor technology 266MRT
Differential pressure transmitter with multisensor technology 266MST
ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

ABB TTH300-Y0-H-BF Head Mounted Temperature Transmitters

PS501 1SAP190100R0001

TU532 1SAP217000R0001

TB521-ARCNET 1SAP112100R0160