Feature:
Product characteristics
Type of lightInfrared light
Electrical designPNP/NPN; (configurable)
ProtectionIP 65; IP 67
Electrical data
Operating voltage[V]19.2…28.8 DC
Protection classIII
Reverse polarity protectionyes
Max. power-on delay time[ms]300
Type of lightInfrared light
Wave length[nm]880
Receiver
Current consumption[mA]100
Transmitter
Current consumption[mA]15
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 1
Outputs
Electrical designPNP/NPN; (configurable)
Number of digital outputs1
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC[V]2
Max. current load per output[mA]100
Switching frequency DC[Hz]12
Short-circuit protectionyes
Overload protectionyes
Monitoring range
Number of beams165
Sensing field height[mm]1640
Sensing field width (low light intensity)[m]0…2
Sensing field width (high light intensity)[m]1…10
Distance between beams[mm]10
Software / programming
Parameter setting optionshysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
Profiles
Common – I&DIdentification and Diagnosis
FunctionMultiple switching signal
SIO modeyes
Required master port classA
Min. process cycle time[ms]10.4
IO-Link process data (cyclical)
Functionbit length
process value80
device status4
binary switching information2
IO-Link functions (acyclical)application specific tag; operating hours counter
Supported DeviceIDs
Type of operationDeviceID
default1402
Note
For further information please see the IODD PDF file at “Downloads”
Operating conditions
Ambient temperature[癈]-10…55
Storage temperature[癈]-25…70
ProtectionIP 65; IP 67
Max. immunity to extraneous light[klx]10
Tests / approvals
EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated3 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted3 V
EN 55011class A
Vibration resistance
EN 60068-2-6 Fc(10-55) Hz 1 mm amplitude, vibration duration 5 min., 30 min. per axis with resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea30 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
MTTF[years]59
Mechanical data
Weight[g]5
Housingrectangular
Dimensions[mm]1713 x 30 x 28
Materialhousing: aluminum; front lens: PC
Length L[mm]1713
Displays / operating elements
Display
transmitter2 LED
receiver3 LED
Accessories
Items supplied
Assembly angle: 3
Slot nuts: 3
Nuts
Remarks
Pack quantity1 pcs.
Electrical connection – receiver
ConnectionConnector: 1 x M12; coding: A
Electrical connection – transmitter
ConnectionConnector: 1 x M12; coding: A
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.