Measurement of flow and temperature at the same time
Optimized for water, oils and air
Red/green display for clear identification of the acceptable range
With switching output, analog signal and IO-Link
The process connection can be rotated for optimum alignment

Technical Specification of IFM SA5000 Thermal Flow Sensors with Display

Product characteristics of IFM SA5000 Thermal Flow Sensors with Display

Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Process connection threaded connection M18 x 1,5 Internal thread

Application of IFM SA5000 Thermal Flow Sensors with Display

System gold-plated contacts
Media water; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C] -20…90
Pressure rating [bar] 100
Pressure rating [Mpa] 10
MAWP (for applications according to CRN) [bar] 100

Electrical data of IFM SA5000 Thermal Flow Sensors with Display

Operating voltage [V] 18…30 DC
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 10

Inputs / outputs of IFM SA5000 Thermal Flow Sensors with Display

Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1

Outputs of IFM SA5000 Thermal Flow Sensors with Display

Total number of outputs 2
Output signal switching signal; analog signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 250
Number of analog outputs 1
Analog current output [mA] 4…20; (scalable)
Max. load [Ω] 350
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Frequency of the output [Hz] 0…1000

Measuring/setting range of IFM SA5000 Thermal Flow Sensors with Display

Probe length L [mm] 45
Operating mode relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended)
Note on factory setting
Operating mode: relative
Temperature monitoring
Measuring range [°C] -20…90
Resolution [°C] 0.2
Liquid media – absolute operating mode
Setting range [m/s] 0.04…3
Greatest sensitivity [m/s] 0.04…3
Liquid media – relative operating mode
Setting range [m/s] 0.04…6
Greatest sensitivity [m/s] 0.04…3
Gases – operating mode “absolute”
Setting range [m/s] 0…100
Greatest sensitivity [m/s] 30…100
Gases – operating mode “relative”
Setting range [m/s] 0…200
Greatest sensitivity [m/s] 30…100
Accuracy / deviations of IFM SA5000 Thermal Flow Sensors with Display

Temperature drift [cm/s x 1/K] 0,003 m/s x 1/K (< 20 °C; > 70 °C)
Max. temperature gradient of medium [K/min] 100

Absolute operating mode of IFM SA5000 Thermal Flow Sensors with Display

Repeatability 0,05 m/s; (water; Flow velocity: 0,05…3 m/s)
Relative operating mode of IFM SA5000 Thermal Flow Sensors with Display

Accuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20…70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Repeatability 0,05 m/s; (water; Flow velocity: 0,05…3 m/s)

Temperature monitoring of IFM SA5000 Thermal Flow Sensors with Display

Temperature drift ± 0,005 K/°C
Accuracy [K] ± 0,3 / ± 1; (water; Flow velocity: 0,3…3 m/s / air; Flow velocity: > 10 m/s)

Reaction times of IFM SA5000 Thermal Flow Sensors with Display

Response time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)

Temperature monitoring of IFM SA5000 Thermal Flow Sensors with Display

Dynamic response T05 / T09 [s] 1,5 (T09); (water; Flow velocity: 0,3…3 m/s)

Software / programming of IFM SA5000 Thermal Flow Sensors with Display

Parameter setting options hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color

Interfaces of IFM SA5000 Thermal Flow Sensors with Display

Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port class A
Process data analog 2
Process data binary 2
Min. process cycle time [ms] 3
Supported DeviceIDs
Type of operation
DeviceID
Factory setting / ModE = (REL)
533
ModE = (LIQU)
540
ModE = (GAS)
547

Operating conditions of IFM SA5000 Thermal Flow Sensors with Display

Ambient temperature [°C] -40…80
Storage temperature [°C] -40…100
Protection IP 65; IP 67
Similar Models of IFM SA5000 Thermal Flow Sensors with Display
SA6010 26.6 mm stainless steel (1.4404 / 316L) PNP/NPN 1/2″ NPT normally open / closed; (configurable); analog
SA4310 200 mm stainless steel (1.4404 / 316L) PNP/NPN Diameter Ø 8 mm normally open / closed; (configurable); analog
SA5010 45 mm stainless steel (1.4404 / 316L); Gasket: FKM PNP/NPN M18 x 1,5 Internal thread normally open / closed; (configurable); analog
SA5000 45 mm stainless steel (1.4404 / 316L); Gasket: FKM PNP/NPN M18 x 1,5 Internal thread normally open / closed; (configurable); analog
SA6014 26.6 mm stainless steel (1.4404 / 316L) 1/2″ NPT analog
SA4114 100 mm stainless steel (1.4404 / 316L) Diameter Ø 8 mm analog
SA4100 100 mm stainless steel (1.4404 / 316L) PNP/NPN Diameter Ø 8 mm normally open / closed; (configurable); analog
SA4314 200 mm stainless steel (1.4404 / 316L) Diameter Ø 8 mm analog
SA4300 200 mm stainless steel (1.4404 / 316L) PNP/NPN Diameter Ø 8 mm normally open / closed; (configurable); analog
SA5014 45 mm stainless steel (1.4404 / 316L); Gasket: FKM M18 x 1,5 Internal thread analog
SA2000 19.2 mm stainless steel (1.4404 / 316L); Gasket: FKM PNP/NPN G 1/2 normally open / closed; (configurable); analog
SA4104 100 mm stainless steel (1.4404 / 316L) Diameter Ø 8 mm analog
SA2004 19.2 mm stainless steel (1.4404 / 316L); Gasket: FKM G 1/2 analog
SA5004 45 mm stainless steel (1.4404 / 316L); Gasket: FKM M18 x 1,5 Internal thread analog
SA4304 200 mm stainless steel (1.4404 / 316L) Diameter Ø 8 mm analog
Ordering Models of IFM SA5000 Thermal Flow Sensors with Display