MTL5514D MTL4514D Switch Proximity Detectors Interface
Description of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4514D – MTL5514D SWITCH/ PROXIMITY DETECTOR INTERFACE
1-channel, dual output, LFD, phase reversal
The MTLx514D enables two safe–area loads to be controlled, through relays, by a proximity detector or switch located in a hazardous area.
When selected, open or short circuit conditions in the field wiring are detected by the line fault detect (LFD) facility and indicated on the top of the module.
Switches are provided to select phase reversal and to enable the line fault detection.
Technical Specification of MTL5514D MTL4514D Switch Proximity Detectors Interface
See also common specification
Number of channels
One
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults are
indicated by an LED. The channel output relays are de-energised if
an input line-fault is detected
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4514D: two, single pole relays with normally-open contacts
MTL5514D: two, single pole relays with changeover contacts
Note: reactive loads must be adequately suppressed
LED indicators of MTL5514D MTL4514D Switch Proximity Detectors Interface
Green: power indication
Yellow: channel status, on when output energised
Red: LFD indication, on when line fault detected
Maximum current consumption
29mA at 24V dc
Power dissipation within unit
0.7W at 24V
Safety description of MTL5514D MTL4514D Switch Proximity Detectors Interface
Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc
(See ‘MTL4000 Series’ for detailed specifications and circuit diagrams)
MTL4041A: Current repeater, 4/20mA, passive input for smart transmitters
MTL4041B: Repeater power supply, 4/20mA, for 2- or 3-wire transmitters
MTL4041P: High power repeater power supply, 4/20mA, for 2- or 3-wire transmitters
MTL4044: Repeater power supply, 4/20mA, two channel, for 2 wire transmitters
MTL4046/C: Isolating driver, for HART® valve positioners
MTL4046P: High power isolating driver for HART® valve positioners
MTL4840 SERIES ORDERING INFORMATION of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4841 HART communications module pre-configured for Cornerstone™ protocol
MTL4841-AMS HART communications module pre-configured for AMS Intelligent Device Manager
MTL4841-PRM HART communications module pre-configured for PRM
MTL4842 HART interface module(communicates with up to 16 loops)
General purpose connection units of MTL5514D MTL4514D Switch Proximity Detectors Interface
BPHM64 64 ch HART backplane HART interface connector
HCU16 HART connection unit No parallel resistor, 0Ω link fitted in series
HCU16-P250 HART connection unit 250Ω parallel resistor, 0Ω link fitted in series
HCU16-S200 HART connection unit No parallel resistor, 200Ω resistor fitted in series
HCU16-S150 HART connection unit No parallel resistor, 150Ω resistor fitted in series
HCU16AO 16 ch HART connection unit With HART filters
HMU16 16 ch HART communication unit
BPMH16 16 ch backplane Safe-area multiway connector
BPSH16 16 ch backplane Safe-area screw-clamp connector
BPSH16-32 32 ch HART backplane
BPMH16U 16 ch HART backplane Requires backplane adapter card (call MTL for options)
Backplane accessories of MTL5514D MTL4514D Switch Proximity Detectors Interface
VMPH16 Backplane mounting plate For DIN-rail and non-metallic surface mounting(BPMH16 and BPSH16 only)
DMK01 DIN-rail mounting kit DIN-rail mounting kit, T- or G-section (pack of 40) 16-way backplanes require 6
SMS01 Surface mounting kit Pack of 40 – 4 required for each backplane
HM64RIB10-xx Ribbon Cable 10-way -xx specifies the cable length – max 4m
HM64RIB20-xx Ribbon Cable 20-way -xx specifies the cable length – max 4.5m
Isolating interface modules and accessories of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4041A Current repeater 4/20mA, passive input, for smart transmitters
MTL4041B Repeater power supply 4/20mA, for 2- or 3-wire transmitters
MTL4041P High power repeater power supply 4/20mA, for 2- or 3-wire transmitters
MTL4044 Repeater power supply 2ch, 4/20mA, smart, for 2-wire transmitters
MTL4046 Isolating driver For HART valve positioners
MTL4046C Isolating driver For HART valve positioners
MTL4046P High power isolating driver For HART valve positioners
CCH01 Crimp connector header
CRC01 Large crimps Pack of 100
CRC02 Small crimps Pack of 100
SCC01 Screw-clamp connector
MPL01 Module position label, blank Pack of 50
Literature of MTL5514D MTL4514D Switch Proximity Detectors Interface
INM4840 MTL4840 instruction manual
Product Code Description of MTL5514D MTL4514D Switch Proximity Detectors Interface
intrinsically safe logo Symbol denotes that the equipment is suitable for use in hazardous area applications.
fsm logo Symbol denotes that the product has been assessed for functional safety applications.
SM45-55-AI SM45-55-AI is FSM FSM Safety Manual – Analogue Input Modules
SM45-55-AO SM45-55-AO is FSM FSM Safety Manual – Analogue Output Modules
SM45-55-BI SM45-55-BI is FSM FSM Safety Manual – Binary Input Modules
SM45-55-MMI SM45-55-MMI is FSM FSM Safety Manual – Machine Monitor Interfaces
SM45-55-SAD SM45-55-SAD is FSM FSM Safety Manual – Solenoid / Alarm Driver Modules
1. Intro of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4501-SR MTL4501-SR is intrinsically safe MTL4501-SR is FSM 1ch DI failsafe solid-state output + LFD alarm
MTL4504 MTL4504 is intrinsically safe MTL4504 is FSM 1ch DI relay output + LFD alarm + phase reversal
MTL4510 MTL4510 is intrinsically safe 4ch DI solid-state output
MTL4510B MTL4510B is intrinsically safe 4ch DI multifunction solid-state output
MTL4511 MTL4511 is intrinsically safe MTL4511 is FSM 1ch DI relay output
MTL4513 MTL4513 is intrinsically safe 2ch DI solid-state output
MTL4514D MTL4514D is intrinsically safe MTL4514D is FSM 1ch switch/prox input, dual output relay
MTL4514_B MTL4514_B is intrinsically safe MTL4514_B is FSM 1ch DI relay output + LFD alarm
MTL4516 MTL4516 is intrinsically safe MTL4516 is FSM 2ch DI relay output
MTL4516C MTL4516C is intrinsically safe MTL4516C is FSM 2ch DI with changeover relay output
MTL4517 MTL4517 is intrinsically safe MTL4517 is FSM 2ch DI relay output + LFD alarm
3. Digital Output of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4525 MTL4525 is intrinsically safe MTL4525 is FSM Switch operated solenoid driver low power
MTL4526 MTL4526 is intrinsically safe 2ch switch operated relay
4. Analogue Input of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4541 MTL4541 is intrinsically safe MTL4541 is FSM 1ch 2/3 wire Transmitter repeater
MTL4541A MTL4541A is intrinsically safe 1ch Transmitter repeater, passive input
MTL4541AS MTL4541AS is intrinsically safe 1ch Transmitter repeater, passive input, current sink
MTL4541T MTL4541T is intrinsically safe 2/3 wire Transmitter repeater
MTL4544 MTL4544 is intrinsically safe MTL4544 is FSM 2ch 2/3 wire Transmitter repeater
MTL4544A MTL4544A is intrinsically safe 2ch Transmitter repeater, passive input
MTL4544AS MTL4544AS is intrinsically safe 2ch Transmitter repeater, passive input, current sink
MTL4544B MTL4544B is intrinsically safe MTL4044 replacement
MTL4544D MTL4544D is intrinsically safe MTL4544D is FSM 2/3 wire transmitter repeater, dual output
MTL4544S MTL4544S is intrinsically safe MTL4544S is FSM 2ch 2/3 transmitter repeater, current sink
5. Analogue Output of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4546 MTL4546 is intrinsically safe MTL4546 is FSM 1ch 4-20mA smart isolating driver + LFD
MTL4546C MTL4546C is intrinsically safe MTL4546C is FSM 1ch 4-20mA smart isolating driver + oc LFD
MTL4546S MTL4546S is intrinsically safe 1ch 4-20mA HART isolating driver + LFD
MTL4546Y MTL4546Y is intrinsically safe MTL4546Y is FSM 1ch 4-20mA smart isolating driver + oc LFD
MTL4549 MTL4549 is intrinsically safe MTL4549 is FSM 2ch 4-20mA smart isolating driver + LFD
MTL4549C MTL4549C is intrinsically safe MTL4549C is FSM 2ch 4-20mA smart isolating driver + oc LFD
MTL4549Y MTL4549Y is intrinsically safe MTL4549Y is FSM 2ch 4-20mA smart isolating driver + oc LFD
6. Temperature Input of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4573 MTL4573 is intrinsically safe 1ch Temperature converter, RTD / THC
MTL4575 MTL4575 is intrinsically safe 1ch Temperature converter, RTD / THC with alarm
MTL4576-RTD MTL4576-RTD is intrinsically safe 2ch Temperature converter, RTD
MTL4576-THC MTL4576-THC is intrinsically safe 2ch Temperature converter, THC
MTL4581 MTL4581 is intrinsically safe 1ch mV/THC isolator for low-level signals
MTL4582B MTL4582B is intrinsically safe MTL4582B is FSM 1ch resistance isolator to repeat RTD signals
7. Pulse and Vibration of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4531 MTL4531 is intrinsically safe MTL4531 is FSM 1ch vibration probe interface
MTL4532 MTL4532 is intrinsically safe 1ch pulse isolator, digital or analogue output
8. Fire and Smoke of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4561 MTL4561 is intrinsically safe MTL4561 is FSM 2ch loop-powered, for fire and smoke detectors
9. General of MTL5514D MTL4514D Switch Proximity Detectors Interface
MTL4599 Dummy isolator
MTL4599N General purpose feed-through module