Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Features
Rotation Speed Monitor KFA5-DWB-Ex1.D
1-channel isolated barrier
115 V AC supply
Dry contact or NAMUR inputs
Input frequency 1 mHz … 5 kHz
2 relay contact outputs
Start-up override
Configurable by keypad
Line fault detection (LFD)
Up to SIL 2 acc. to IEC 61508/IEC 61511
Technical data of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
General specifications of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Signal type Digital Input
Functional safety related parameters of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Safety Integrity Level (SIL) SIL 2
Supply of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Connection terminals 23, 24
Rated voltage 115 V AC +/- 10 %
Rated current 30 mA
Power dissipation/power consumption ≤ 2 VA / 2 VA
Input of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Connection side field side
Connection Input I: intrinsically safe: terminals 1+, 3-
Input II: non-intrinsically safe: terminals 13+, 14-
Input I acc. to EN 60947-5-6 (NAMUR), see manual for electrical data
Pulse duration > 50 µs
Input frequency 0.001 … 5000 Hz
Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input II startup override: 1 … 1000 s, adjustable in steps of 1 s
Active/Passive I > 4 mA (for min. 100 ms)/ I < 1 mA
Open circuit voltage/short-circuit current 18 V / 5 mA
Output of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Connection side control side
Connection output I: terminals 10, 11, 12
output II: terminals 16, 17, 18
Output I, II signal, relay
Contact loading 253 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life 5 x 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Transfer characteristics of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Input I
Measurement range 0.001 … 5000 Hz
Resolution 0.1 % of the measurement value , ≥ 0.001 Hz
Accuracy 0.1 % of the measurement value , > 0.001 Hz
Measuring time < 100 ms
Influence of ambient temperature 0.003 %/K (30 ppm)
Output I, II
Response delay ≤ 200 ms
Galvanic isolation of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Input I/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachother reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Start-up override/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
Labeling space for labeling at the front
Directive conformity of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
Conformity of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Ambient conditions of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Ambient temperature -20 … 60 °C (-4 … 140 °F)
extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions
Mechanical specifications of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Degree of protection IP20
Connection screw terminals
Mass 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
EU-type examination certificate TÜV 99 ATEX 1408
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage 253 V AC (Attention! Um is no rated voltage.)
Input I terminals 1+, 3-: Ex ia
Voltage Uo 10.1 V
Current Io 13.5 mA
Power Po 34 mW (linear characteristic)
Input II terminals 13+, 14- non-intrinsically safe
Maximum safe voltage Um 40 V (Attention! The rated voltage can be lower.)
Output I, II terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Contact loading 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Certificate TÜV 02 ATEX 1885 X
Marking Ex-Hexagon II 3G Ex nA nC IIC T4 Gc
Output I, II
Contact loading 50 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Galvanic isolation
Input I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
FM approval
Control drawing 16-538FM-12
UL approval E223772
IECEx approval
IECEx certificate IECEx TUN 03.0000
IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
General information of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Classifications of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
System Classcode
ECLASS 11.0 27210128
ECLASS 10.0.1 27210128
ECLASS 9.0 27210128
ECLASS 8.0 27210190
ECLASS 5.1 27210121
ETIM 8.0 EC002918
ETIM 7.0 EC002918
ETIM 6.0 EC002918
ETIM 5.0 EC002918
UNSPSC 12.1 39121007
Similar Models of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
KFA6-DWB-Ex1.D
Rotation Speed Monitor
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz … 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-DWB-1.D
Rotation Speed Monitor
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz … 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-DWB-Ex1.D
Rotation Speed Monitor
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz … 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
KFU8-DW-1.D
Rotation Speed Monitor
Speed monitoring up to 40 kHz, 1 pre-select value with relay output and LED indicator, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable, Start-up delay, Menu driven operation via 4 front keys, Construction type: modular terminal housing in Makrolon, System KF
For use in the switch cabinet/switch cabinet module, Rated voltage: 200 … 230 V AC ; 100 … 130 V AC; 50/60 Hz
20 VDC … 30 VDC
KFU8-DWB-1.D
Rotation Speed Monitor
1-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz … 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Rated voltage: 20 … 90 V DC / 48 … 253 V AC 50 … 60 Hz
KFA5-DWB-Ex1.D
Rotation Speed Monitor
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz … 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
S1SD-1FI-1R
Rotation Speed Monitor
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors, Input frequency 10 mHz … 50 kHz, Relay contact output, Start-up override and restart inhibit, Configurable by DIP switches and software, Connection via screw terminals
Ordering Models of Pepperl+Fuchs KFA5-DWB-Ex1.D Rotation Speed Monitors
MTL:
MTL3046B,discontinued,replaced by:MTL5541
MTL3042,discontinued,replaced by:MTL5546Y
MTL5053,discontinued,replaced by:MTL5553
MTL5995,discontinued,replaced by:F101-PS
MTL3000 SERIES (200mA)
MTL4041A,discontinued,replaced by:MTL4541A
MTL4041B,discontinued,replaced by:4541B
MTL5042,discontinued,replaced by:MTL5541
MTL5061,discontinued,replaced by:MTL5561
MTL4842,discontinued,replaced by:MTL4852
FP32