Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Features

HART Multiplexer Slave KFD0-HMS-16

16-channel
No external power required
HART field device input (revision 5 to 7)
Used with HART Multiplexer Master KFD2-HMM-16
Up to SIL 3 acc. to IEC 61508
Technical data of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Product Description of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

HART Multiplexer Slave

Functional safety related parameters of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Safety Integrity Level (SIL) SIL 3

Supply of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Connection via 14-channel flat cable form master KFD2-HMM-16

HART signal channels (non-intrinsically safe) of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Conformity HART field device input (revision 5 to 7)
Connection 26-pin flat cable for analog connections
14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16
Leakage current < 3 µA at -20 … 85 °C (-4 … 185 °F)
Terminating resistor external 230 … 500 Ω standard (up to 1000 Ω possible)
Output voltage ≥ 400 mV ss (with the terminator resistance specified above)
Output resistance 100 Ω or smaller, capacitive coupling
Input impedance according to HART specification
Input voltage range 0.08 … 4 V ss ; typ. ± 5.2 V as local reference

Indicators/settings of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Labeling space for labeling at the front

Directive conformity of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)

Conformity of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Degree of protection IEC 60529:2001

Ambient conditions of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Ambient temperature -20 … 60 °C (-4 … 140 °F)

Mechanical specifications of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Degree of protection IP20
Mass approx. 100 g
Dimensions 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) , housing type B1
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Certificate PF 07 CERT 1143 X
Marking Ex-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-15:2010

General information of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

System Classcode
ECLASS 11.0 27210190
ECLASS 10.0.1 27210190
ECLASS 9.0 27210190
ECLASS 8.0 27210190
ECLASS 5.1 27242692
ETIM 8.0 EC001601
ETIM 7.0 EC001601
ETIM 6.0 EC001601
UNSPSC 12.1 39121008

Similar Models of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

HiDMux2700
HART Multiplexer Master
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC 61508
KFD0-HMS-16
HART Multiplexer Slave
16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508
KFD2-HMM-16
HART Multiplexer Master
16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508
KFD2-HMM-16.1S
HART Multiplexer Master
KCD2-UT2-1
Universal Temperature Converter
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KCD2-UT2-Ex1

Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-1

Universal Temperature Converter
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-2

Universal Temperature Converter
2-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-Ex1

Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-Ex1-1
Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-Ex2

Universal Temperature Converter
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-Ex2-1

Universal Temperature Converter
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-1-1

Universal Temperature Converter
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

KFD2-UT2-2-1

Universal Temperature Converter
2-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511

Ordering Codes of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave

K-LB-1.6 FN-LB-I FP-LB-I FS-LB-I

We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.