Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Features
HART Multiplexer Slave KFD0-HMS-16
16-channel
No external power required
HART field device input (revision 5 to 7)
Used with HART Multiplexer Master KFD2-HMM-16
Up to SIL 3 acc. to IEC 61508
Technical data of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Product Description of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
HART Multiplexer Slave
Functional safety related parameters of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Safety Integrity Level (SIL) SIL 3
Supply of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Connection via 14-channel flat cable form master KFD2-HMM-16
HART signal channels (non-intrinsically safe) of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Conformity HART field device input (revision 5 to 7)
Connection 26-pin flat cable for analog connections
14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16
Leakage current < 3 µA at -20 … 85 °C (-4 … 185 °F)
Terminating resistor external 230 … 500 Ω standard (up to 1000 Ω possible)
Output voltage ≥ 400 mV ss (with the terminator resistance specified above)
Output resistance 100 Ω or smaller, capacitive coupling
Input impedance according to HART specification
Input voltage range 0.08 … 4 V ss ; typ. ± 5.2 V as local reference
Indicators/settings of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Labeling space for labeling at the front
Directive conformity of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Degree of protection IEC 60529:2001
Ambient conditions of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Mechanical specifications of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Degree of protection IP20
Mass approx. 100 g
Dimensions 20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) , housing type B1
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Certificate PF 07 CERT 1143 X
Marking Ex-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-15:2010
General information of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Classifications of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
System Classcode
ECLASS 11.0 27210190
ECLASS 10.0.1 27210190
ECLASS 9.0 27210190
ECLASS 8.0 27210190
ECLASS 5.1 27242692
ETIM 8.0 EC001601
ETIM 7.0 EC001601
ETIM 6.0 EC001601
UNSPSC 12.1 39121008
Similar Models of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
HiDMux2700
HART Multiplexer Master
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC 61508
KFD0-HMS-16
HART Multiplexer Slave
16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508
KFD2-HMM-16
HART Multiplexer Master
16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508
KFD2-HMM-16.1S
HART Multiplexer Master
KCD2-UT2-1
Universal Temperature Converter
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KCD2-UT2-Ex1
Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-1
Universal Temperature Converter
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-2
Universal Temperature Converter
2-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-Ex1
Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-Ex1-1
Universal Temperature Converter
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-Ex2
Universal Temperature Converter
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA … 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-Ex2-1
Universal Temperature Converter
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-1-1
Universal Temperature Converter
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-UT2-2-1
Universal Temperature Converter
2-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V … 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
Ordering Codes of Pepperl+Fuchs KFD0-HMS-16 HART Multiplexer Slave
K-LB-1.6 FN-LB-I FP-LB-I FS-LB-I
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.