Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Features
* RTD Converter KFD0-TR-Ex1
* 1-channel isolated barrier
* 24 V DC supply (loop powered)
* 2- or 3-wire Pt100 RTD input
* Output 4 mA … 20 mA, temperature linearization selectable
* DIP switch selectable ranges
* Sensor breakage detection
Technical data of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
General specifications of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Signal type Analog input
Supply of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Rated voltage 12 … 35 V DC loop powered
Power dissipation 0.4 W
Input of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Connection side field side
Connection terminals 1, 2-, 3+ suitable for Pt100, 2- and 3-wire connection
Lead resistance max. 100 Ω per line
Measuring current approx. 1 mA
Output of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Connection side control side
Connection terminals 9+, 8-
Load (U -12 V) / 0.02 A
Current output 4 … 20 mA , limited to ≤ 35 mA
Fault signal upscaling ≥ 22 mA (limited to 35 mA)
Transfer characteristics of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Measurement range span without linearization 25 … 800 °C (77 … 1472 °F)/with linearization 25 … 375 °C (77 … 707 °F), both adjustable
zero point without linearization -200 … 400 °C (-328 … 752 °F)/with linearization -30 … 375 °C (-22 … 707 °F), both adjustable
Deviation
After calibration 0.1 % of full-scale value incl. linearity and hysteresis
Influence of ambient temperature span and zero point 0.015 % / K or ± 10 mΩ / K
Influence of supply voltage 6.5 ppm/V
Rise time 250 ms
Galvanic isolation of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Input/Output available
Indicators/settings of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Control elements DIP-switch
rotary switch
Configuration via DIP switches
via rotary switch
Labeling space for labeling at the front
Directive conformity of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Insulation coordination EN 50178
Galvanic isolation EN 50178
Degree of protection IEC 60529
Ambient conditions of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Mechanical specifications of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
EU-Type Examination Certificate ZELM 00 ATEX 0036
Marking Ex-Hexagon II (1)GD [EEx ia] IIC
Voltage 16.1 V
Current 33 mA
Power 131 mW
Certificate TÜV 01 ATEX 1777 X
Marking Ex-Hexagon II 3G Ex nA II T4
Galvanic isolation
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
CSA approval
Control drawing 116-0132
General information of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Ordering Models of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
KFD0-CC-Ex1
Current/Voltage Converter
1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 … 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
KFD0-SD2-Ex2.1045
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-CC-1
Current/Voltage Converter
1-channel signal conditioner, 24 V DC supply (loop powered), Current or voltage input, Output: 4 … 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
KFD0-CS-Ex1.50P
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex1.51P
Current Driver/Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex2.50P
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex2.51P
Current Driver/Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, SIL 2 (SC 3) acc. to IEC/EN 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex2.52
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Transfer direction: to the control system
KFD0-RO-Ex2
Relay Module
2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC … 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
KFD0-SCS-Ex1.55
SMART Current Driver/Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system
KFD0-SD2-Ex1.10100
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex1.1180
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex2.1245
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-TR-Ex1
RTD Converter
1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA … 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
KFD0-TT-Ex1
Thermocouple Converter
1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA … 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges
KFD0-CS-Ex2.54
Repeater
2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
KFD0-HMS-16
HART Multiplexer Slave
16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508
KFD0-RSH-1.4S.PS2
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC … 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
KFD0-TR-1
RTD Converter
1-channel signal conditioner, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA … 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
KFD0-CS-1.50
Repeater
1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-2.50
Repeater
2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-2.51P
Current Driver/Repeater
2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 0 mA … 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-CS-Ex1.52
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Transfer direction: to the control system
KFD0-CS-Ex1.54
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
KFD0-LGH
Place Holder Barrier
K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers
KFD0-LGH-GN
Place Holder Barrier
K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers
KFD0-LGH-Y34868
Place Holder Barrier
K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, No electrical function: empty housing
KFD0-RO-2
Relay Module
2-channel signal conditioner, 24 V DC supply (loop powered), Logic input 15 V DC … 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
KFD0-RSH-1.1D.F1
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC … 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
KFD0-RSH-1.1E.1
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC … 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
KFD0-SCS-1.55
SMART Current Driver/Repeater
1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA … 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
KFD0-TT-1
Thermocouple Converter
1-channel signal conditioner, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA … 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges
KFD0-CS-Ex1.54-Y2
Repeater
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA … 20 mA, Transfer direction: to the control system
KFD0-LGH-5T
Place Holder Barrier
K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers, Two additional green terminal blocks supplied separately
KFD0-LGH-Y39343
Place Holder Barrier
K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via DIP switches and plug-in jumpers
KFD0-SD2-Ex1.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-RSH-1
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 16 V DC … 30 V DC, non-polarized, Fail-safe relay contact output, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex1.1065
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-RSH-1-Y2
Relay Module
1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC … 30 V DC, non-polarized, Fail-safe relay contact output, Test pulse immunity, Up to SIL 3 acc. to IEC 61508
Ordering Codes of Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
Pepperl+Fuchs KFD0-TR-Ex1 RTD Converter
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers,Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.