Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Product Features of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Switch Amplifier, Timer Relay KFD2-DU-Ex1.D

1-channel isolated barrier
24 V DC supply (Power Rail)
Dry contact or NAMUR inputs
Relay contact and transistor output
Adjustable output timer functions from 10 ms … 60 min
Input frequency up to 80 Hz; pulse divider up to 1 kHz
Reset function
Configurable by keypad
Line fault detection (LFD)
Technical Specification of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

General specifications of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Signal type Digital Input

Supply of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Connection Power Rail or terminals 23+, 24-
Rated voltage 20 … 30 V DC
Rated current approx. 100 mA
Power consumption 1.8 W

Input of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Connection side field side
Connection Input I: terminals 1+, 3- ; input II: terminals 13+, 14-
Input I acc. to EN 60947-5-6 (NAMUR), see manual for electrical data
Open circuit voltage/short-circuit current 8.2 V / 10 mA
Switching point/switching hysteresis 1.2 … 2.1 mA / approx. 0.2 mA
Pulse duration min. 75 µs / 1 ms see instruction manuals; the maximum input frequency has to be observed.
Input frequency 0 … 80 Hz , pulse divider 0 … 1 kHz
Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input II reset
Active/Passive I > 4 mA/I < 1.5 mA
Open circuit voltage/short-circuit current 18 V / 5 mA
Pulse duration min. 10 ms

Output of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Connection side control side
Connection output I: terminals 10, 11, 12 ; output II: terminals 19+, 20-
Output I signal , Relay output
Contact loading 253 V AC/ 2 A / cos φ ≥ 0.7 ; 40 V DC/ 2 A
Mechanical life 5 x 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output II signal , electronic unit, isolated
Contact loading 40 V / 50 mA
Energized/De-energized delay after rising input flank 3 ms ; after falling input flank 2 ms
Signal level 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof)
0-signal: blocked output (off-state current ≤ 10 µA)

Transfer characteristics of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Input I
Resolution < 0.1 % of the set value, min. 10 ms
Accuracy 2 ms
Influence of ambient temperature 0.003 %/K (50 ppm)
Galvanic isolation
Input I/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I/power supply and reset reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachother reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output II/power supply and collective error basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output II/reset basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Reset/power supply and collective error functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff

Indicators/settings of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
Labeling space for labeling at the front

Directive conformity of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010

Conformity of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001

Ambient conditions of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Ambient temperature -20 … 60 °C (-4 … 140 °F)

Mechanical specifications of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Degree of protection IP20
Connection screw terminals
Mass approx. 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

EU-type examination certificate TÜV 99 ATEX 1408
Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage 40 V DC (Attention! The rated voltage can be lower.)
Input I terminals 1+, 3-: Ex ia
Voltage Uo 10.1 V
Current Io 13.5 mA
Power Po 34 mW (linear characteristic)
Input II terminals 13+, 14- non-intrinsically safe
Maximum safe voltage Um 40 V (Attention! The rated voltage can be lower.)
Output I terminals 10, 11, 12 non-intrinsically safe
Contact loading 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Output II terminals 19+, 20- non-intrinsically safe
Maximum safe voltage 40 V (Attention! The rated voltage can be lower.)
Certificate TÜV 02 ATEX 1885 X
Marking Ex-Hexagon II 3G Ex nA nC IIC T4 Gc
Output I
Contact loading 50 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Galvanic isolation
Input I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010

International approvals of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

FM approval
Control drawing 16-538FM-12
UL approval E223772
IECEx approval
IECEx certificate IECEx TUN 03.0000
IECEx TSA 18.0007X
IECEx marking [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Ex ec nC IIC T4 Gc

General information of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

System Classcode
ECLASS 11.0 27210121
ECLASS 10.0.1 27210121
ECLASS 9.0 27210121
ECLASS 8.0 27210121
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
UNSPSC 12.1 32101514

Similar Models of Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

HiC2821
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2822
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2831
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2831R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2831R2
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2841
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2842
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2853
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
HiC2853R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive), Line fault transparency (LFT), Up to SIL 3 acc. to IEC/EN 61508
KCD2-SOT-1.LB
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
KCD2-SOT-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SOT-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KFA5-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFA5-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFA6-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms … 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
KFA6-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFA6-SR-2.3L
Switch Amplifier
2-channel signal conditioner, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508
KFA6-SR-2.3L.FA
Switch Amplifier
2-channel, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508
KFA6-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
KFA6-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFA6-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFA6-SR2-Ex2.W.IR
Switch Amplifier
2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
KFD2-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC/EN 61508, Up to PL d acc. to EN/ISO 13849
KFD2-SH-Ex1.T.OP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
KFD2-SOT3-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-SOT3-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-SOT3-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-SOT3-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
KFD2-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-SR3-2.2S
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-SR3-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-SRA-Ex4
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation
KFD2-ST3-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), SIL 2 (SC 3) acc. to IEC/EN 61508
KFD2-ST3-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
KFU8-SR-1.3L.V
Switch Amplifier, Timer Relay
1-channel signal conditioner, Universal usage at different power supplies, 3-wire PNP/NPN sensor or push-pull input, 2 relay contact outputs, Adjustable energized/de-energized delay
KHA6-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 115/230 V AC supply, Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC/EN 61508, Up to PL d acc. to EN/ISO 13849
HiC2851
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
HiC2853R2
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Application-specific outputs, Active voltage output, Passive transistor output (resistive), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
KCD2-SOT-2
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SOT-2.SP
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
HiD2824
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
HiD2844
Switch Amplifier
4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 passive transistor outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
HiC2832R1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SOT-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KFA5-SR2-Ex2.W
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
KFD2-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms … 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
S1SD-1DI-1R
Switch Amplifier
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors or AC/DC voltage sources, Relay contact output, Timer function, Configurable by DIP switches, Connection via screw terminals
WE 77/Ex-1 115V
Switch Amplifier
1-channel, Control circuit EEx ia IIC, 115 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact)
WE 77/Ex-1 230V
Switch Amplifier
1-channel, Control circuit EEx ia IIC, 230 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact)
WE 77/Ex-2 115V
Switch Amplifier
2-channel, Control circuit EEx ia IIC, 115 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact) per channel
WE 77/Ex-2 230V
Switch Amplifier
2-channel, Control circuit EEx ia IIC, 230 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact) per channel
HiC2831R3
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2832
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2832R2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
HiC2832R3
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508
KCD2-SON-Ex1.R1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as signal splitter (1 input and 2 outputs), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex1.R2
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex1.R3
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex1.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex2.R1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex2.R2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex2.R3
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SON-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-SOT-1.LB.SP
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC/EN 61508
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
KCD2-SOT-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-1.LB
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-1.LB.SP
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-2
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-2.SP
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KCD2-ST-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, SIL 2 (SC 3) acc. to IEC/EN 61508
KFA4-SR2-Ex2.W
Switch Amplifier
2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact) per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFA5-DU-Ex1.D
Switch Amplifier, Timer Relay
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms … 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
KFA5-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFA5-SR2-Ex2.W.IR
Switch Amplifier
2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
KFD2-SOT3-Ex2.IO-Y1
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508
KFA4-SR2-Ex1.W
Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact), EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFA4-SR2-Ex1.W.LB
Switch Amplifier
1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: relay contact output (change-over contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-SR2-2.2S
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
KFD2-SR2-Ex2.2S
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-Ex2.IO-Y181008
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation
KCD2-SR-1.LB
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
KCD2-SR-2
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
KCD2-SR-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
KCD2-SR-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
KCD2-SR-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
KCD2-SR-Ex2.SP
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-SOT2-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-ST2-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KFD2-ST2-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
KCD2-SR-1.LB.SP
Switch Amplifier
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
KCD2-SR-2.SP
Switch Amplifier
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508



Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

FDH-1
Fieldbus Diagnostic Handheld
Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.23.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 21 … 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 28 … 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-B
Fieldbus Power Hub, Basic Diagnostic Module
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play – no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module
PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

KFD2-BR-1.PA.1500
Basic Segment Coupler
Output: 24 … 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
KFD2-BR-Ex1.3PA.93
Segment Coupler 1
Output: 12.6 … 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator
KLD0-SAA
Voltage adjustment module
Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-FBPS-1.25.360
Fieldbus Power Supply
Output: 25 … 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
R-SP-E12
Segment Protector for Cabinet Installation
Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
ARS11-B2-IC08-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC08-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC16-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC16-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC24-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC24-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

ARS12-B2-IC08-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC08-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC16-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC16-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC24-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC24-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics
ELS-1
Enclosure Leakage Sensor
Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA
FBTA-228-BPFB-R-8R
Compact Fieldbus Power Hub Motherboard for Invensys FBM 228
8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play – no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-FBPS-1.12.220
Fieldbus Power Supply
Output: 12 … 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
KLD2-PR-1.IEC
Fieldbus Power Repeater
Output: 24 … 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

KT-MB-DMA
Advanced Diagnostic Module, Kit for Stand-Alone Operation
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA
KT-SRT-FF
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure, Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 … 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
KT-SRT-PA
Starter Kit for PROFIBUS PA Infrastructure
Starter Kit for PROFIBUS PA Infrastructure, Complete hardware for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 … 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
Output: 25 … 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

KLD2-PR-Ex1.IEC
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment
KLD2-PR-Ex1.IEC1
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment
RD0-TI-EX8.FF.ST-Y1
Temperature Multi-Input Device for Cabinet Installation
Temperature Multi-Input Device for Cabinet Installation
EI-0D2-10Y-10B
Intrinsically safe Ethernet Isolator
Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
DP-LBF-I1.36.*
Fieldbus Surge Protector for Cabinet Installation, Ex ia
Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-FT-Ex1
Fieldbus Terminator, Field Installation, Ex ia
Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-D1.32
Fieldbus Surge Protector, Field Installation, Ex d
Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for ‘+’ and ‘-‘ fieldbus lead, Choice of threads 20 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-I1.32
Fieldbus Surge Protector, Field Installation, Ex ia
Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for ‘+’ and ‘-‘ fieldbus lead, Choice of threads 20 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

F.FB0.P**.A**.1.0.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.S**.A**.1.0.***.***.****
FieldBarrier Junction Box, Stainless Steel
4, 8 or 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB0.T**.***.1.0.***.***.****
FieldBarrier Junction Box
FieldBarrier Junction Box, Brushed Stainless Steel, 4, 8 or 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 – high-power trunk
Zone 1 – high-power trunk, Device coupler location [2]: Zone 1 – high-power trunk, Instrument location / spur protection: Zone 0 … 1 – intrinsic safety, Function: Device coupler, Design / Mounting: Outside installation
F.FB1.P14.A**.1.*.***.***.****
FieldBarrier Junction Box, Polyester (GRP)
8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB1.S14.A**.1.*.***.***.****
FieldBarrier Junction Box, Stainless Steel
8, 10, 12 outputs Ex ia, Electropolished enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.FB1.T14.***.1.*.***.***.****
FieldBarrier Junction Box
FieldBarrier Junction Box, Brushed Stainless Steel, 8, 10, 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 – high-power trunk
Zone 1 – high-power trunk, Device coupler location [2]: Zone 1 – high-power trunk, Instrument location / spur protection: Zone 0 … 1 – intrinsic safety, Function: Device coupler, Design / Mounting: Outside installation
F.MIO.P12.*12.F.*.***.***.**00
Multi-Input/Output Junction Box, Polyester (GRP)
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.MIO.P12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box, Polyester (GRP)
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.MIO.S12.*12.F.*.***.***.**00
Multi-Input/Output Junction Box, Stainless Steel
For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.MIO.S12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box, Stainless Steel
For discrete inputs and outputs, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.MIO.T12.*12.P.*.***.***.**00
Multi-Input/Output Junction Box
Multi-Input/Output Junction Box, Brushed Stainless Steel, For discrete inputs and outputs, Brushed enclosure, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 – high-power trunk
Zone 1 – high-power trunk
Zone 1/2 – intrinsically safe high-power trunk
Zone 1 – intrinsically safe trunk, Device coupler location [2]: Zone 2 – high-power trunk

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

F.SP5.P**.B**.1.0.***.***.***0
Segment Protector Junction Box, Polyester (GRP)
4 … 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SP5.S**.B**.1.0.***.***.***0
Segment Protector Junction Box, Stainless Steel
4 … 12 outputs Ex ic (FISCO or Entity), Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SP5.T**.***.1.*.***.***.****
Segment Protector Junction Box
Segment Protector Junction Box, Brushed Stainless Steel, 4 … 12 outputs Ex ic (FISCO or Entity), Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 – high-power trunk, Device coupler location [2]: Zone 2 – high-power trunk
F.SPE.P**.A**.1.0.***.***.****
Segment Protector Junction Box, Polyester (GRP)
Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SPE.S**.A**.1.0.***.***.****
Segment Protector Junction Box, Stainless Steel
Connection of Ex d certified devices, Stainless steel, electropolished, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.SPE.T**.A**.1.0.***.***.****
Segment Protector Junction Box
Segment Protector Junction Box, Brushed Stainless Steel, Connection of Ex d certified devices, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 – high-power trunk, Instrument location / spur protection: Zone 1 – increased safety, Function: Device coupler, Design / Mounting: Outside installation
F.TI0.P12.*08.F.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.TI0.P12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Polyester (GRP)
8 channel universal temperature interface, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.TI0.S12.*08.F.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F.TI0.S12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box, Stainless Steel
8 channel universal temperature interface, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F.TI0.T12.*08.P.0.***.***.**00
Temperature Multi-Input Junction Box
Temperature Multi-Input Junction Box, Brushed Stainless Steel, 8 channel universal temperature interface, Brushed enclosure, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, Device coupler location: non-explosion hazardous area
Zone 2 – high-power trunk
Zone 1 – high-power trunk
Zone 1/2 – intrinsically safe high-power trunk
Zone 1 – intrinsically safe trunk, Device coupler location [2]: Zone 2 – high-power trunk

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

F.VC0.P21.A04.*.*.***.***.*000
Valve Coupler Junction Box, Polyester (GRP)
4 valve control and 8 position feedback signals, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F.VC0.S20.A04.*.*.***.***.*000
Valve Coupler Junction Box, Stainless Steel
4 valve control and 8 position feedback signals, Stainless steel, electropolished, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2-JB-#.*
Fieldbus junction box
4 … 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity
F2-JB-I#.*
Fieldbus junction box
4 … 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0…1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2-SP-IC*
Fieldbus Segment Protector
Fieldbus Segment Protector, 4 … 10 outputs Ex ic (FISCO or Entity), Advanced fault isolation at the spur, Segment Protector in Zone 2, Instruments in Zone 2 or Zone 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2D0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F2D0-MIO-Ex12.FF.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1
F2D0-MIO-Ex12.PA.*
Multi-Input/Output Device with Aluminum Housing
For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA
F2D0-TI-Ex8.FF.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
F2D0-TI-Ex8.PA.*
Temperature Multi-Input Device with Aluminum Housing
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

MB-FB-GTR1*
Fieldbus Power Hub, Gateway Motherboard
For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable
MBHC-FB-4*
Compact Fieldbus Power Hub, Motherboard, Common Interface
4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4.GT*
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics
MBHC-FB-4.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4R*
Compact Fieldbus Power Hub Motherboard with Common Interface
4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4R.YO*
Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R*
Compact Fieldbus Power Hub, Motherboard, Common Interface
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.RH*
Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
MBHC-FB-8R.YO*
Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1

Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay

R2-SP-IC*
Segment Protector for Cabinet Installation
4 … 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R4D0-FB-IA*
FieldBarrier® for Cabinet Installation
FieldConnex® FieldBarrier®, 8 … 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R8D0-MIO-Ex12.FF*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
RD0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay
RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
RD0-TI-Ex8.PA.*
Temperature Multi-Input Device for Cabinet Installation
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
SCP-LBF-IA1.36.IE*
Fieldbus Surge Protector, Field Installation on Spur
Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-AL*.***
Segment Protector Junction Box, Aluminum
Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-CS*.***
Segment Protector Junction Box, Carbon Steel
Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-FB*.***
Segment Protector Junction Box, Polyester (GRP)
Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-PCW.***
Segment Protector Junction Box, Polycarbonate
Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
SPJB-**-SS*.***
Segment Protector Junction Box, Stainless Steel
Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA
TCP-LBF-IA1.36.IE*
Fieldbus Surge Protector, Field Installation on Trunk
Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
TPH-LBF-IA1.36.DE*
Fieldbus Surge Protector, Trunk Installation on Power Hub
Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA
Pepperl+Fuchs KFD2-DU-Ex1.D Switch Amplifiers, Timer Relay