Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Features
Solenoid Driver KFD2-RCI-Ex1
1-channel isolated barrier
24 V DC supply (Power Rail)
Output 20.4 mA at 13.5 V DC
19 V DC … 30 V DC input
Line fault detection (LFD)
Conformal coating
Up to SIL 3 acc. to IEC 61508
Technical data of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
General specifications
Signal type Digital Output
Functional safety related parameters of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Safety Integrity Level (SIL) SIL 3
Supply of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Connection Power Rail or terminals 14+, 15-
Rated voltage 19 … 30 V DC
Rated current < 35 mA
Power consumption < 0.8 W
Input of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Connection side control side
Connection terminals 10+, 11-
Input current 40 mA at 19 … 30 V DC
Signal level 1-signal: 19 … 30 V DC
0-signal: 0 … 5 V DC
Power consumption < 1.2 W
Operating mode loop powered
Output of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Connection side field side/control side
Output I
Connection terminals 1+, 3- (terminals 1+, 2 for test loop)
Current max. 20.4 mA
Voltage min. 13.5 V
Current 1-signal: 20.4 mA
0-signal: 4.2 mA
Voltage 1-signal: > 13.5 V
Load max. 650 Ω
Response time < 40 ms input to output
Line fault detection short circuit voltage < 1 V , open circuit voltage > 16 V
Output II
Connection terminal 7: source (-) or sink (+), terminal 8: source (+), terminal 9: sink (-)
Current 11 mA (source or sink mode)
Voltage 9 … 30 V sink mode from external supply
Load max. 650 Ω , source mode , for HART ≥ 230 Ω
Communication pass-through of HART signal between input II and output
Galvanic isolation of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Input/power supply functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Output II/power supply functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Indicators/settings of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Display elements LEDs
Control elements DIP-switch
Configuration via DIP switches
Labeling space for labeling at the front
Directive conformity of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Electromagnetic compatibility NE 21:2012
Degree of protection IEC 60529:2001
Ambient conditions of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Mechanical specifications of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
EU-type examination certificate CESI 09 ATEX 037
Marking Ex-Hexagon II (1)GD [Ex ia] IIC; [Ex iaD] [circuit(s) in zone 0/1/2/20/21/22]
Equipment terminals 1+, 2 / 3-
Voltage 25.4 V
Current 93.6 mA
Power 595 mW (linear characteristic)
Supply
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Input
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Collective error message
Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
Certificate PF 09 CERT 1438 X
Marking Ex-Hexagon II 3G Ex nA IIC T4 Gc
Galvanic isolation of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
Output I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
CSA approval
Control drawing 116-0335
IECEx approval
IECEx certificate IECEx CES 09.0008
IECEx marking [Ex ia] IIC , [Ex iaD]
General information of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers KFD2-RCI-Ex1 Safety Barriers
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Classifications of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
System Classcode
ECLASS 11.0 27210190
ECLASS 10.0.1 27210190
ECLASS 9.0 27210190
ECLASS 8.0 27210190
ECLASS 5.1 27210121
ETIM 8.0 EC001485
ETIM 7.0 EC001485
ETIM 6.0 EC001485
ETIM 5.0 EC001485
Similar models of Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
KFD0-SD2-Ex1.10100
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex1.1180
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex2.1045
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex2.1245
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508
KFD2-SL-4
Solenoid Driver, Power Amplifier
4-channel signal conditioner, 24 V DC supply (Power Rail), Output 600 mA per channel, Logic inputs, Common safety-oriented disable input, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Output rated operating current: 600 mA per channel , sustained short-circuit proof and overload-proof
Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
KFD2-SL2-Ex2
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SL2-Ex2.B
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
KFD2-VM-Ex1.35.L
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator function test, Input: with prelogic
KFD2-RCI-Ex1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC … 30 V DC input, Line fault detection (LFD), Conformal coating, Up to SIL 3 acc. to IEC 61508
HiC2883
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
HiD2872
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL 3 acc. to IEC 61508 (loop powered)
HiD2876
Solenoid Driver
2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508 (loop powered)
KCD0-SD3-Ex1.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
KCD0-SD3-Ex1.1245
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
KCD2-SLD-Ex1.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
KCD2-SLD-Ex1.1065
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
KCD2-SLD-Ex1.1245
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
HiC2871A
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Test pulse immunity, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
HiC2877
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 3 acc. to IEC 61508 (loop powered)
KCD0-SD3-Ex1.1245.SP
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
KFD2-SLD-Ex1.13100
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Logic input, Output 100 mA at 13 V DC, Alternating outputs for the operation of solenoids with 2 coils, High output power for IIB gas group, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC 61508
HiC2871
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508
HiC2873
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 12 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 110 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL 3 acc. to IEC 61508 (loop powered)
KCD0-SD-Ex1.1245
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Up to SIL 3 acc. to IEC 61508
KCD0-SD-Ex1.1245.SP
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC 61508
KFD0-SD2-Ex1.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
Pepperl+Fuchs KFD2-RCI-Ex1 Solenoid Drivers
KFD0-SD2-Ex1.1065
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC 61508
KFD2-SL2-Ex1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SL2-Ex1.B
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
KFD2-SL2-Ex1.LK
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SL2-Ex1.LK-Y1
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Increased input load, Output 45 mA at 11.2 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
KFD2-SL2-Ex1.LK.1045
Solenoid Driver
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 10 V DC, Logic input, non-polarized, Fault indication output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508