Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Product Features of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Frequency voltage current converter KFU8-FSSP-1.D
Limit frequency 40 kHz
Voltage or current ouptput
Incrementing output
(Spacing factor 1 … 9999)
Multi-range power pack
2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable
Auxiliary power output for sensors
Connection via Power Rail
Period measurement
Display: Input in Hz or 1/min, output in V or mA
adjustable updating of indication (0,001 … 2,5 s)
Technical data of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Product Description of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Frequency voltage current converter
40 kHz version
Functional safety related parameters of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
MTTFd 100 a
Supply of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Rated voltage 200 … 230 V AC ; 100 … 130 V AC; 50 Hz
20 VDC … 30 VDC
Fusing external fusing 4 A
Power consumption AC: < 5 VA
DC: < 5 W
Indicators/operating means of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Type 4-digit, 7-segment red display, 7 mm digit height
Display interval 0.002 … 9999 Hz or
0.01 … 9999 min-1
Parameter assignment keypad-driven menu
Input 1 of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Connection terminals 8-, 9+
Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6
Open loop voltage 8.2 V DC
Short-circuit current 6.5 mA
Switching point 1.2 … 2.1 mA Switching hysteresis approx. 0.2 mA
Impedance 1.2 kOhm
Input 2 of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Switching point high: 16 … 30 V DC; max.10 mA; Ri ≅ 3 kOhm
low: 0 … 6 V DC
Connection terminals 7+, 13- sensor supply
terminals 14, 15 NPN/PNP input (galvanically isolated)
Connectable sensor types 2-, 3-, or 4-wire proximity switches and incremental rotary encoder
Sensor supply 19 … 28 V DC non-stabilised; ≤ 30 mA short-circuit protected
Output of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Analog voltage output 0 … 10 V DC; 2 … 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≥ 330 Ω (terminal 5+, 6-)
Analog current output 0 … 20 mA; 4 … 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+)
Digital incrementing ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+)
with frequency division Fin /1 … Fin /9999
Transfer characteristics of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Input frequency ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µs
Deviation ≤ 0.2 % of full-scale value
Changing interval 5 ms (Internal processing time)
Standard conformity of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Electromagnetic compatibility acc. to EN 50081-2 / EN 50082-2
Ambient conditions of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Ambient temperature -25 … 40 °C (-13 … 104 °F)
Storage temperature -40 … 85 °C (-40 … 185 °F)
Relative humidity max. 80 %, not condensing
Altitude 0 … 2000 m
Operating conditions The device has only to be used in an indoor area.
Mechanical specifications of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
Connection assembly Caution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device.
Degree of protection IP20
Connection coded, removable terminals , max. core cross section 0.34 … 2.5 mm2
Construction type modular terminal housing in Makrolon, System KF
For use in the switch cabinet/switch cabinet module
Mounting snap-on to 35 mm standard rail or screw fixing
Classifications of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
System Classcode
ECLASS 11.0 27210904
ECLASS 10.0.1 27210904
ECLASS 9.0 27210904
ECLASS 8.0 27210904
ECLASS 5.1 27210904
ETIM 8.0 EC002918
ETIM 7.0 EC002918
ETIM 6.0 EC002918
ETIM 5.0 EC002918
UNSPSC 12.1 39121007
Similar Models of Pepperl+Fuchs KFU8-FSSP-1.D Frequency Voltage Current Converters
KCD2-E2L
Sensor output interface terminal
Single-channel terminal amplifier with line breakage detection, input for NAMUR sensors, DC 24 V supply voltage, standardized interface to prevent signal transmission errors, switching state display, LED yellow
KCD2-R
Sensor output interface terminal
Relay output with 1 pole, yellow LED indicates switching state, Free-wheeling diode, Compact terminal housing, Clips onto standard 35 mm rail to DIN EN 50 022, Degree of protection IP20
KFU8-FSSP-1.D
Frequency voltage current converter
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 … 9999), Multi-range power pack, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable, Rated voltage: 200 … 230 V AC ; 100 … 130 V AC; 50 Hz
20 VDC … 30 VDC
K23-SSI/USB/25B-C
Signal Converter
Multifunction device with operating modes for incremental rotary encoders, SSI absolute rotary encoders, and rotary encoders with start/stop interface, USB interface for configuring and reading, Extremely short conversion times, User-definable, non-linear characteristic curve with 24 interpolation points, Auxiliary voltage output 5 V DC and 24 V DC for rotary encoder supply, Operating voltage: 10 … 30 V DC, Input type: Incremental, Input format: RS422, TTL, HTL differential, HTL PNP, or HTL NPN
KCD2-E1
Sensor output interface terminal
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LED
KCD2-E3
Sensor output interface terminal
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LED
KCD2-EL
Sensor output interface terminal
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LED
K23-SSI/Rx/IU-C
Signal Converter
Multifunction device with operating modes for incremental rotary encoders, SSI absolute rotary encoders, and rotary encoders with start/stop interface, 16 bit analog output, configurable for voltage or current operations, USB interface and RS232/RS485 interface for configuration and readout, Extremely short conversion times, User-definable, non-linear characteristic curve with 24 interpolation points, Operating voltage: 18 … 30 V DC, Input type: Incremental
KFU8-UFC-1.D.FA
Frequency Converter with Trip Values
1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz … 10 kHz, Current output 0/4 mA … 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring
KFU8-FSSP-1.D-Y322444
Frequency voltage current converter
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 … 9999), 2-, 3-, 4-wire sensors and rotary encoder can be connected, Auxiliary power output for sensors, Rated voltage: 20 … 30 V DC
KFU8-UFT-2.D.FA
Frequency Converter with Direction and Synchronization Monitor
2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz … 1 kHz, Current output 0/4 mA … 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Rated voltage: 20 … 90 V DC / 48 … 253 V AC 50 … 60 Hz, Input I, II: 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact, Output I, II: signal, relay, Output V: analog
KFU8-FSSP-1.D-Y180599
Frequency voltage current converter
Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 … 9999), 2-, 3-, 4-wire sensors and rotary encoder can be connected, Auxiliary power output for sensors, Rated voltage: 20 … 30 V DC