Product Features of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
FieldBarrier® RDO-FB-Ex4.COM
4 outputs Ex ia IIC
FieldBarrier in Zone 1/Div. 2
Instruments in Zone 0…1/Div. 1
Short circuit current limitation per output
For FOUNDATION Fieldbus H1 and PROFIBUS PA
Power, Com, and Error LEDs
Supports FISCO and Entity
Integrated cable tie-downs
Supports all grounding methods
Function of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
The FieldBarrier, a device coupler for DIN rail mounting, connects 4 instruments with intrinsic safety (Ex ia/Ex ib) and short circuit current limitation at each output. This ensures proper operation of the segment during faults or hot work at the spur.
High power on the trunk enables maximum cable lengths and device count in any hazardous area. The integrated fieldbus terminator features high-availability design and is selectable.
Output terminals with a choice of fixed or plug-in screw terminals connect 1 device each. LEDs simplify troubleshooting and help decrease repair time. Any grounding and shielding concept is possible based on FieldConnex® enclosure solutions
Technical data of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
General specifications of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Design / Mounting Cabinet installation
Fieldbus connection of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Main cable (Trunk)
Connection input (Trunk IN): terminals 3+, 4-, 5s
output (Trunk OUT): terminals 7-, 8+, 6s
Rated voltage 32 … 16 V DC
Rated current 31 mA … 26 mA (without load)
77 mA … 115 mA (at 20 mA load per input)
120 mA … 209 mA (at 40 mA load per input)
135 mA … 241 mA (short-circuit on all outputs)
Voltage drop trunk IN to trunk OUT 100 mV max.
Number of couplers max. 4 per segment
Outputs
Number of devices per output 1
Connection output 1: terminals 10+, 11-, 12S shield;
output 2: terminals 13+, 14-, 15S shield;
output 3: terminals 16+, 17-, 18S shield;
output 4: terminals 19+, 20-, 21S shield
Rated voltage 10 … 13 V
Rated current max. 43 mA
Short-circuit current 50 mA
Indicators/operating means of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
LED voltage Fieldbus green: on, bus voltage existent
LED status output red flashing: short-circuit
Galvanic isolation of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Main wire/outputs isolation is not affected by interference according to EN 50020, voltage peak value 375 V
Directive conformity of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013
Standard conformity of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Electromagnetic compatibility NE 21:2006
Degree of protection IEC/EN 60529
Fieldbus standard IEC 61158-2
Climatic conditions DIN IEC 721
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3
Ambient conditions of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Ambient temperature -50 … 70 °C (-58 … 158 °F)
Storage temperature -40 … 85 °C (-40 … 185 °F)
Mechanical specifications of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Connection type fixed terminals, plug-in terminals
Core cross section up to 2.5 mm2
Housing see figure 1
Housing material Polycarbonate
R… DIN rail housing PA 6.6
Degree of protection IP20
Mass 1050 g
Mounting mounting on DIN rail in cabinet
Data for application in connection with hazardous areas of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
EU-type examination certificate PTB 02 ATEX 2086
Marking Ex-Hexagon II 2 (1) G Ex eb mb [ia Ga] IIC T4 Gb ,
Ex-Hexagon II (1) D [Ex ia Da] IIIC
Main cable (Trunk)
Maximum safe voltage Um 253 V AC
Outputs
Power 975 mW
Voltage 15.75 V
Current 248 mA
Directive conformity
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-18:2015 , EN 60079-31:2013
International approvals of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
FM approval CoC 3015728
Control drawing No. 116-0226
Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx nA [ia] IIC T4
CSA approval CoC 1845315
Control drawing 116-0266
Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, Ex nA [ia] IIC T4
IECEx approval IECEx PTB 03.0003
Approved for Ex eb mb [ia Ga] IIC T4 Gb , [Ex ia Da] IIIC
Certificates and approvals of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
FOUNDATION Fieldbus FF-846
Marine approval DNV A-14038
General information of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Classifications of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
System Classcode
ECLASS 11.0 27242605
ECLASS 10.0.1 27242605
ECLASS 9.0 27242605
ECLASS 8.0 27242605
ECLASS 5.1 27242605
ETIM 8.0 EC001601
ETIM 7.0 EC001601
ETIM 6.0 EC001601
ETIM 5.0 EC001604
UNSPSC 12.1 39121008
Similar Models of Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
FDH-1
Fieldbus Diagnostic Handheld
Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.23.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 21 … 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HCD2-FBPS-1.500
Fieldbus Power Hub, Compact Power Supply Module
Output: 28 … 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-A
Fieldbus Power Hub, Advanced Diagnostic Module
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-DM-B
Fieldbus Power Hub, Basic Diagnostic Module
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play – no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module
PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting
Pepperl+Fuchs RDO-FB-Ex4.COM FieldBarrier
KFD2-BR-1.PA.1500
Basic Segment Coupler
Output: 24 … 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
KFD2-BR-Ex1.3PA.93
Segment Coupler 1
Output: 12.6 … 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator
KLD0-SAA
Voltage adjustment module
Series voltage reducing module, Removable terminals, Polarity reversal protected, Installation in cabinet on DIN mounting rail, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-FBPS-1.25.360
Fieldbus Power Supply
Output: 25 … 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA
R-SP-E12
Segment Protector for Cabinet Installation
Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
ARS11-B2-IC08-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC08-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC16-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC16-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC24-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS11-B2-IC24-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch
ARS12-B2-IC08-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC08-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC16-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC16-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC24-1
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
ARS12-B2-IC24-2
Ethernet-APL Rail Field Switch
Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP and S2 redundancy, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC … 60 VDC, Function: Ethernet-APL Rail Field Switch, Design / Mounting: Cabinet installation
HD2-GTR-4PA.PN
PROFINET Power Hub, Gateway Module
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics
ELS-1
Enclosure Leakage Sensor
Housing leakage sensor, for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA
FBTA-228-BPFB-R-8R
Compact Fieldbus Power Hub Motherboard for Invensys FBM 228
8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
HD2-DM-A.RO
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play – no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KLD2-FBPS-1.12.220
Fieldbus Power Supply
Output: 12 … 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1
KLD2-PR-1.IEC
Fieldbus Power Repeater
Output: 24 … 26 V/400 mA, For extension of fieldbus segments, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-MB-DMA
Advanced Diagnostic Module, Kit for Stand-Alone Operation
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA
KT-MB-GT2AD.FF.IO
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA
KT-SRT-FF
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure
Starter Kit for FOUNDATION Fieldbus H1 Infrastructure, Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice, Output: 25 … 28 V/360 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
KT-SRT-PA
Starter Kit for PROFIBUS PA Infrastructure
Starter Kit for PROFIBUS PA Infrastructure, Complete hardware for connection of PROFIBUS PA field devices to a DP-Master, Output: 24 … 26 V/400 mA, Connection of 6 field devices with individual short-circuit protection, High-power trunk for high device count and long cable lengths
Output: 25 … 28 V/360 mA, Universal power supply for most applications, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA
Pepperl+Fuchs HD2-DM-A Fieldbus Power Hub, Advanced Diagnostic Modules HD2-DM-A
KLD2-PR-Ex1.IEC
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to Entity, 70 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment
KLD2-PR-Ex1.IEC1
Fieldbus Power Repeater
Power supply of fieldbus segments according to IEC 61158-2, Signal repeater for fieldbus topologies in accordance to FISCO, 100 mA supply of the field side, Improves the fieldbus signal, Extension of the transmission distance by means of opening a new fieldbus segment
RD0-TI-EX8.FF.ST-Y1
Temperature Multi-Input Device for Cabinet Installation
Temperature Multi-Input Device for Cabinet Installation
EI-0D2-10Y-10B
Intrinsically safe Ethernet Isolator
Galvanic Isolation I.S. to non-I.S. Port, 10/100 MBit/s according to IEEE 802.3/.3u, Installation in Zone 2, Ethernet in Zone 1 or Zone 0, Standard Ethernet patch or crossover cable, DIN-Rail mounted and OEM Version
DP-LBF-I1.36.*
Fieldbus Surge Protector for Cabinet Installation, Ex ia
Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-FT-Ex1
Fieldbus Terminator, Field Installation, Ex ia
Terminator in stainless steel housing, Intrinsically safe, FISCO and flameproof enclosure (Ex d), Installation on open cable gland, Choice of threads 20 mm, Pg 13.5 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-D1.32
Fieldbus Surge Protector, Field Installation, Ex d
Surge Protector in stainless steel housing, Flameproof enclosure (Ex d) protection, Surge protection for ‘+’ and ‘-‘ fieldbus lead, Choice of threads 20 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
F*-LBF-I1.32
Fieldbus Surge Protector, Field Installation, Ex ia
Surge Protector in stainless steel housing, Intrinsically safe, FISCO or Entity, Surge protection for ‘+’ and ‘-‘ fieldbus lead, Choice of threads 20 mm or 1/2″ NPT, For FOUNDATION Fieldbus H1 and PROFIBUS PA
MB-FB-GTR1*
Fieldbus Power Hub, Gateway Motherboard
For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable
MBHC-FB-4*
Compact Fieldbus Power Hub, Motherboard, Common Interface
4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4.GT*
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics
MBHC-FB-4.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4.YO*
Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111
4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4R*
Compact Fieldbus Power Hub Motherboard with Common Interface
4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-4R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA
MBHC-FB-4R.YO*
Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R*
Compact Fieldbus Power Hub, Motherboard, Common Interface
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.HSC*
Compact Fieldbus Power Hub, Motherboard, Host System Connector
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
MBHC-FB-8R.RH*
Compact Fieldbus Power Hub, Motherboard, Redundant Host Terminals
8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA
MBHC-FB-8R.YO*
Compact Fieldbus Power Hub Motherboard for Yokogawa ALF111
8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
R2-SP-IC*
Segment Protector for Cabinet Installation
4 … 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R4D0-FB-IA*
FieldBarrier® for Cabinet Installation
FieldConnex® FieldBarrier®, 8 … 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA
R8D0-MIO-Ex12.FF*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1
R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA
RD0-FB-Ex4.*
FieldBarrier®
4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0…1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA