Control Techniques Unidrive SP / SPM AC Drives
CoversUnidrive SP / SPM
Control Techniques (Emerson / Nidec) Unidrive SP panel-mount drives and Unidrive SPM modular drives (SPMA, SPMD with SPMC/SPMU rectifiers): how the SP model number reads, ND/HD ratings of common models and FAQs.
- Supply voltage classes
- 2: 200–240 V; 4: 380–480 V; 5: 500–575 V; 6: 500–690 V
- Ratings
- Dual rated: Normal Duty (ND) and Heavy Duty (HD)
Availability and lead time confirmed on request
Overview
Control Techniques Unidrive SP and SPM AC Drives (Emerson): Models and Order Codes
The Unidrive SP is the Control Techniques (formerly Emerson, now Nidec) universal AC drive range, in panel-mount SP models and modular SPM units for high power. We can supply them: HKXYTECH is an independent supplier and every drive is 100% original and brand-new. Lead time is quoted per inquiry. We ship worldwide by DHL, UPS or FedEx air express or by sea freight, accept payment by T/T (your local currency is also supported) and reply to every inquiry within 24 hours.
How the Unidrive SP model number reads
| SP | Unidrive SP (Solutions Platform) complete inverter drive |
|---|---|
| Digit 1: frame size | 0 to 6 |
| Digit 2: voltage | 2: 200–240 V; 4: 380–480 V; 5: 500–575 V; 6: 500–690 V |
| Digit 3: configuration | 0 = wall-mount drive |
| Digit 4: current rating step | 1, 2, 3 … within the frame |
| SPMA / SPMD | Modular drives: SPMA AC-input inverter; SPMD DC-input inverter (used with SPMC / SPMU rectifier) |
Example: SP1404 = frame 1, 380–480 V, wall-mount, current step 4: ND 6.9 A / 3.0 kW, HD 5.8 A / 2.2 kW.
Ratings of common models (400 V class)
| SP0402 | HD 1.7 A / 0.55 kW |
|---|---|
| SP1402 | ND 3.8 A / 1.5 kW; HD 3.0 A / 1.1 kW |
| SP1404 | ND 6.9 A / 3.0 kW; HD 5.8 A / 2.2 kW |
| SP2401 | ND 15.3 A / 7.5 kW; HD 13 A / 5.5 kW |
| SP5401 | ND 138 A / 75 kW; HD 124 A / 55 kW |
| SP5402 | ND 168 A / 90 kW; HD 156 A / 75 kW |
| SPMA1401 / SPMA1421 | ND 205 A / 110 kW; HD 180 A / 90 kW |
| SPMA1402 / SPMA1422 | ND 236 A / 132 kW; HD 210 A / 110 kW |
| SPMD1401 / 1402 / 1403 | 205 A / 110 kW; 246 A / 132 kW; 290 A / 160 kW |
| SPMD1404 | 335 A / 185 kW with rectifier docked; 350 A / 200 kW undocked |
Before you order
- Give the full model number and, if fitted, the option modules (SM-…) you use, so we match the same configuration.
- Check the duty (ND or HD) you size for: the same model has two ratings.
Frequently asked questions
Can you ship the Unidrive SP AC drive to the Middle East, Central Asia or Africa?
Yes. We ship worldwide, including the Middle East, Central Asia and Africa, by DHL, UPS or FedEx air express or by sea freight. Lead time and freight for your destination are quoted per inquiry.
What is the difference between SPMA and SPMD?
Both are Unidrive SPM modular drives. The SPMA takes an AC supply and has its own input stage; the SPMD takes a DC supply and is used with an SPMC or SPMU rectifier unit.
Is the Unidrive SP AC drive original and brand-new?
Yes. We supply 100% original, brand-new units. HKXYTECH is an independent supplier and is not affiliated with the manufacturer.
Do you provide a test report or certificate of origin (COO)?
Tell us which documents you need when you send the inquiry. We confirm per order which documents can be supplied with the unit.
Do you have stock for an urgent or shutdown replacement?
Stock changes daily, so availability is confirmed per inquiry. Send the full order code from the nameplate and mark the inquiry urgent; we reply within 24 hours with availability and lead time.
What if my model is discontinued?
Send the full order code from the nameplate. If the exact configuration is no longer made, we check the current equivalent from the same manufacturer and confirm it with you before quoting.
What are your payment and shipping terms?
Payment by T/T (bank transfer); payment in your local currency is also supported. Shipping by DHL, UPS or FedEx air express, or by sea freight. Lead time is quoted per inquiry.
Related models
Order codes in this series
88 order codes from this series are collected on this page. Send the full code from the label or your parts list when you ask for a quote.
Show all 88 codes
SP0201SP0202SP0203SP0204SP0205SP0401SP0402SP0403SP0404SP0405SP1201SP1202SP1203SP1204SP1401SP1402SP1403SP1405SP1406SP2201SP2202SP2203SP2402SP2403SP2404SP3201SP3202SP3401SP3402SP3403SP3501SP3502SP3503SP3504SP3505SP3506SP3507SP4201SP4202SP4203SP4401SP4402SP4403SP4601SP4602SP4603SP4604SP4605SP4606SP5201SP5202SP5401SP5601SP5602SP6401SP6402SP6411SP6412SP6601SP6602SP7411SP7412SP8411SP8412SP8413SP8414SP9410SP9411SP9412SP9413SP9414SP9415SPMA1401SPMA1402SPMA1601SPMA1602SPMD1201SPMD1202SPMD1203SPMD1204SPMD1401SPMD1402SPMD1403SPMD1404SPMD1601SPMD1602SPMD1603SPMD1604
Source: Control Techniques Unidrive SP User Guide, Issue 15 (part 0471-0000-15); Control Techniques Unidrive SPM User Guide, Issue 5 (part 0471-0053-05).
Specifications
| Range | Unidrive SP panel-mount (frames 0–6) and Unidrive SPM modular |
|---|---|
| Supply voltage classes | 2: 200–240 V; 4: 380–480 V; 5: 500–575 V; 6: 500–690 V |
| Ratings | Dual rated: Normal Duty (ND) and Heavy Duty (HD) |
| SPM modules | SPMA = AC in / AC out; SPMD = DC in / AC out, fed by an SPMC or SPMU rectifier |
| Operating modes | Open loop (vector, fixed V/F, quadratic V/F), RFC, closed-loop vector, servo and regen |
Source: Control Techniques Unidrive SP User Guide, Issue 15 (part 0471-0000-15); Control Techniques Unidrive SPM User Guide, Issue 5 (part 0471-0053-05). Confirm with the manufacturer datasheet before ordering.
Documents
- DatasheetPDF · on request Request
- Operating manualPDF · on request Request
- Certificate copy (with order, where available)PDF · on request Request