Endress+Hauser Levelflex FMP55 SensorFusion Interface Level News
Endress+Hauser Levelflex FMP55: When One Tank Has Two Levels and a 2750 mm Decision
Quick answer: Levelflex FMP55 is a multiparameter interface transmitter combining guided-wave radar and capacitance through SensorFusion. It can report overall level and liquid-liquid interface simultaneously, including challenging emulsion layers. For a traceable quotation, send the full reference: FMP55 FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM.
E+H Item Picture 2 — single product image for FMP55 series sourcing enquiries.
Two products can share the same tank but have very different dielectric constants, conductivity and emulsion behavior. The full option code, probe length, process connection and both media properties must travel together from engineering to purchasing.
The hidden supply-chain risk is the layer nobody describes
Oil-water separators, chemical settlers and petrochemical vessels rarely offer a perfect, razor-sharp boundary. Emulsions can expand, conductivity can shift and the upper layer can weaken the interface echo. A quotation that says only “interface level transmitter” may compare devices that solve different measurement problems.
FMP55 uses SensorFusion: guided radar plus capacitance. The two principles reinforce the measurement and allow simultaneous overall-level and interface signals. Capacitance can support the interface value when the interface echo is difficult, subject to the conductivity conditions and configured probe. That makes the application data—not the catalog family name—the starting point for an accurate offer.
FMP55 series capability snapshot
| Engineering item | FMP55 series reference data |
|---|---|
| Measuring principle | Multiparameter: capacitance and guided-wave radar / time-of-flight |
| Measurement task | Simultaneous overall level and liquid-liquid interface, including emulsion layers |
| Typical industries | Oil & gas, chemical and petrochemical processing |
| Accuracy | Rod, rope and coaxial probes: ±2 mm under reference conditions |
| Process conditions | -40°C to +200°C; vacuum to 40 bar |
| Maximum range | Rod 4 m; rope 10 m; coaxial 6 m; Min DK > 1.4 |
| Main wetted materials | 316 / 316L, PTFE and PFA, depending on probe configuration |
| Process connection | Flange options including ASME, DN and JIS; exact type and rating must be decoded |
| Communication | 4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus; optional Bluetooth |
| Quotation example | FMP55 FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM |
CA=2750MM belongs beside the order code
The 2750 mm probe dimension controls the active geometry inside the vessel: where the sensing path begins and ends, how it clears internal structures and whether it can cover the required interface range. Keep CA=2750MM attached to the complete FMP55 code on the RFQ, commercial comparison and purchase order. If a supplier returns a shortened description, request the complete decoded configuration before treating it as an equivalent offer.
SensorFusion still needs the chemistry
For capacitance-assisted interface measurement, the electrical behavior of both layers matters. A typical suitability check asks whether the upper medium is non-conductive and the lower medium is conductive; the exact application must be reviewed using current manufacturer guidance. Also provide emulsion thickness, expected dielectric constants, conductivity, temperature and pressure. Without those details, “stock available” is not the same as “fit for service.”
A high-conversion RFQ checklist for FMP55 buyers
Full model and option code, including CA=2750MM or the required probe length.
Names, densities, dielectric constants and conductivities of the upper and lower media.
Expected overall level, interface range and maximum emulsion-layer thickness.
Operating and design temperature and pressure, foam, agitation and changing-product conditions.
Vessel drawing, nozzle geometry, internals, bottom clearance and probe preference.
Flange standard, size, pressure class, facing and wetted-material requirement.
Signal protocol, hazardous-area, SIL, WHG or marine approvals, quantity and destination.
Buyer FAQ for GEO visibility
What does the Endress+Hauser FMP55 measure?
It measures continuous overall liquid level and the interface between two liquids. Its SensorFusion design combines guided radar and capacitance to support difficult interface applications, including emulsion layers.
Is FMP55 suitable for an oil-water interface?
It is designed for liquid-liquid interface applications, but suitability depends on dielectric constant, conductivity, emulsion behavior, probe design and process conditions. Send both media properties for review.
Does every FMP55 have a 2750 mm probe?
No. Probe length is order-specific. The reference in this enquiry list includes CA=2750MM; another FMP55 code may have a different length or probe construction.
How do I request FMP55 price, stock and lead time?
Send FMP55 FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM, quantity, both media properties, process data, connection and delivery country.
Complete E+H level-instrument references currently receiving enquiries
All models below are hot-selling enquiry references. Copy the entire second-column code into your RFQ; the short family name alone is not enough for an accurate offer.
| Series | Complete enquiry reference |
|---|---|
| FMR43 | FMR43-AABADFNX1X2JGFC+TC |
| FMR20B | FMR20B-AABADTBMVCGVEEB |
| FMR10B | FMR10B-AAAADTBMWDGWEEB |
| FMR30B | FMR30B-AABAKHBMXQ0VEE3 |
| FMR67 | FMR67B-AABAFBCJGPEBESJD1+EH |
| FMR62 | FMR62-NBBCAAGMF5MRK |
| FMR60 | FMR60-AAALAAGAA3XJG |
| FWR30 | FWR30-AA1B1B7B0+PC |
| FMR20 | FMR20-AAABNWDEXR01 |
| FMR10 | FMR10-AAQBMWDEWFE2 |
| NMR84 | NMR84-IC1BB1C2B1ACABFB1AHJITD |
| NMR81 | NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3 |
| FMR67B | FMR67B-AABAENAFGAJCRBFD3 |
| FMR66B | FMR66B-AABAEDAHBSI1WFEA |
| FMR62B | FMR62B-AABACAAJGNEBEUKB+AA |
| FMR60B | FMR60B-AABAEJAFBSJCRCFA+LA |
| FMR54 | FMR54-AAACCABDD1AJJ+AAEHJALA |
| FMR52 | FMR52-BCACCBBPAGK+AA |
| FMR51 | FMR51-BBACCABCA5AGJ |
| FMP50 | FMP50-BCACCBAAA1GDJ+AAF371,2M |
| FMP51 | FMP51-BAACCABCB3ARJ+AA, 7000MM |
| FMP52 | FMP52-AAACCAOACHK+AAIJZ1 (2050MM) |
| FMP53 | FMP53-AAACCADAB5TDJ L=560 mm |
| FMP54 | FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM) |
| FMP55 | FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM |
| FMP56 | FMP56-AAAAAALAABGDE |
| FMP57 | FMP57-AAACCAAEA4GGE (2000mm) |
| FMU40 | FMU40-ARB2A2 |
| FMU41 | FMU41-1NB2A2 |
| FMU42 | FMU42-AVB2A42A |
| FMU44 | FMU44-ATB2A23A |
| FMU30 | FMU30-AAHEAAGGF |
| FMG50 | FMG50-AABADJACA |
becky@hkxytech.com
+86 15972186287
Please include the full code, CA=2750MM, both media properties, process conditions, quantity and delivery country.
HKXYTECH is an independent industrial-instrument supplier. Product names and trademarks belong to their respective owners. Series limits, approvals and SensorFusion suitability must be verified against the selected configuration and current manufacturer documentation.
Latest News
-
Endress+Hauser Levelflex FMP55 SensorFusion Interface Level News
September
29, 2026
-
Endress+Hauser Levelflex FMP54 High Temperature Radar Level News
September
28, 2026
-
Endress+Hauser Levelflex FMP53 Hygienic Radar Level News
September
24, 2026
-
Endress+Hauser Levelflex FMP52 PFA-Coated Radar Level News
September
23, 2026
-
Drive and Motion Buyers Prepare for Schneider Electric September Price Revision
September
23, 2026
-
Endress+Hauser Levelflex FMP51 Guided Radar Level News
September
22, 2026