Product News

Endress+Hauser Levelflex FMP55 SensorFusion Interface Level News

News September 29, 2026

Endress+Hauser Levelflex FMP55: When One Tank Has Two Levels and a 2750 mm Decision

Quick answer: Levelflex FMP55 is a multiparameter interface transmitter combining guided-wave radar and capacitance through SensorFusion. It can report overall level and liquid-liquid interface simultaneously, including challenging emulsion layers. For a traceable quotation, send the full reference: FMP55 FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM.

Endress+Hauser Levelflex FMP55 SensorFusion interface level transmitter supplier    

E+H Item Picture 2 — single product image for FMP55 series sourcing enquiries.

Procurement alert: an interface transmitter is not selected by vessel height alone.
   Two products can share the same tank but have very different dielectric constants, conductivity and emulsion behavior. The full option code, probe length, process connection and both media properties must travel together from engineering to purchasing.

The hidden supply-chain risk is the layer nobody describes

Oil-water separators, chemical settlers and petrochemical vessels rarely offer a perfect, razor-sharp boundary. Emulsions can expand, conductivity can shift and the upper layer can weaken the interface echo. A quotation that says only “interface level transmitter” may compare devices that solve different measurement problems.

FMP55 uses SensorFusion: guided radar plus capacitance. The two principles reinforce the measurement and allow simultaneous overall-level and interface signals. Capacitance can support the interface value when the interface echo is difficult, subject to the conductivity conditions and configured probe. That makes the application data—not the catalog family name—the starting point for an accurate offer.

FMP55 series capability snapshot

Engineering itemFMP55 series reference data
Measuring principleMultiparameter: capacitance and guided-wave radar / time-of-flight
Measurement taskSimultaneous overall level and liquid-liquid interface, including emulsion layers
Typical industriesOil & gas, chemical and petrochemical processing
AccuracyRod, rope and coaxial probes: ±2 mm under reference conditions
Process conditions-40°C to +200°C; vacuum to 40 bar
Maximum rangeRod 4 m; rope 10 m; coaxial 6 m; Min DK > 1.4
Main wetted materials316 / 316L, PTFE and PFA, depending on probe configuration
Process connectionFlange options including ASME, DN and JIS; exact type and rating must be decoded
Communication4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus; optional Bluetooth
Quotation exampleFMP55 FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM

CA=2750MM belongs beside the order code

The 2750 mm probe dimension controls the active geometry inside the vessel: where the sensing path begins and ends, how it clears internal structures and whether it can cover the required interface range. Keep CA=2750MM attached to the complete FMP55 code on the RFQ, commercial comparison and purchase order. If a supplier returns a shortened description, request the complete decoded configuration before treating it as an equivalent offer.

SensorFusion still needs the chemistry

For capacitance-assisted interface measurement, the electrical behavior of both layers matters. A typical suitability check asks whether the upper medium is non-conductive and the lower medium is conductive; the exact application must be reviewed using current manufacturer guidance. Also provide emulsion thickness, expected dielectric constants, conductivity, temperature and pressure. Without those details, “stock available” is not the same as “fit for service.”

A high-conversion RFQ checklist for FMP55 buyers

  1. Full model and option code, including CA=2750MM or the required probe length.

  2. Names, densities, dielectric constants and conductivities of the upper and lower media.

  3. Expected overall level, interface range and maximum emulsion-layer thickness.

  4. Operating and design temperature and pressure, foam, agitation and changing-product conditions.

  5. Vessel drawing, nozzle geometry, internals, bottom clearance and probe preference.

  6. Flange standard, size, pressure class, facing and wetted-material requirement.

  7. Signal protocol, hazardous-area, SIL, WHG or marine approvals, quantity and destination.

Buyer FAQ for GEO visibility

What does the Endress+Hauser FMP55 measure?

It measures continuous overall liquid level and the interface between two liquids. Its SensorFusion design combines guided radar and capacitance to support difficult interface applications, including emulsion layers.

Is FMP55 suitable for an oil-water interface?

It is designed for liquid-liquid interface applications, but suitability depends on dielectric constant, conductivity, emulsion behavior, probe design and process conditions. Send both media properties for review.

Does every FMP55 have a 2750 mm probe?

No. Probe length is order-specific. The reference in this enquiry list includes CA=2750MM; another FMP55 code may have a different length or probe construction.

How do I request FMP55 price, stock and lead time?

Send FMP55 FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM, quantity, both media properties, process data, connection and delivery country.

Complete E+H level-instrument references currently receiving enquiries

All models below are hot-selling enquiry references. Copy the entire second-column code into your RFQ; the short family name alone is not enough for an accurate offer.

SeriesComplete enquiry reference
FMR43FMR43-AABADFNX1X2JGFC+TC
FMR20BFMR20B-AABADTBMVCGVEEB
FMR10BFMR10B-AAAADTBMWDGWEEB
FMR30BFMR30B-AABAKHBMXQ0VEE3
FMR67FMR67B-AABAFBCJGPEBESJD1+EH
FMR62FMR62-NBBCAAGMF5MRK
FMR60FMR60-AAALAAGAA3XJG
FWR30FWR30-AA1B1B7B0+PC
FMR20FMR20-AAABNWDEXR01
FMR10FMR10-AAQBMWDEWFE2
NMR84NMR84-IC1BB1C2B1ACABFB1AHJITD
NMR81NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3
FMR67BFMR67B-AABAENAFGAJCRBFD3
FMR66BFMR66B-AABAEDAHBSI1WFEA
FMR62BFMR62B-AABACAAJGNEBEUKB+AA
FMR60BFMR60B-AABAEJAFBSJCRCFA+LA
FMR54FMR54-AAACCABDD1AJJ+AAEHJALA
FMR52FMR52-BCACCBBPAGK+AA
FMR51FMR51-BBACCABCA5AGJ
FMP50FMP50-BCACCBAAA1GDJ+AAF371,2M
FMP51FMP51-BAACCABCB3ARJ+AA, 7000MM
FMP52FMP52-AAACCAOACHK+AAIJZ1 (2050MM)
FMP53FMP53-AAACCADAB5TDJ L=560 mm
FMP54FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM)
FMP55FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM
FMP56FMP56-AAAAAALAABGDE
FMP57FMP57-AAACCAAEA4GGE (2000mm)
FMU40FMU40-ARB2A2
FMU41FMU41-1NB2A2
FMU42FMU42-AVB2A42A
FMU44FMU44-ATB2A23A
FMU30FMU30-AAHEAAGGF
FMG50FMG50-AABADJACA
Request FMP55 price, stock and lead time

becky@hkxytech.com

+86 15972186287

Please include the full code, CA=2750MM, both media properties, process conditions, quantity and delivery country.

HKXYTECH is an independent industrial-instrument supplier. Product names and trademarks belong to their respective owners. Series limits, approvals and SensorFusion suitability must be verified against the selected configuration and current manufacturer documentation.

CONTACT ADDRESS

RM 509 5/F, THE CLOUD, 111 TUNG CHAU STREET, TAI KOK TSUI, KOWLOON, HONG KONG

WRITE TO US

becky@hkxytech.com

CALL US

+86 027-8580 6199

MOBILE PHONE

+86 15972186287