Pepperl+Fuchs Purge and Pressurization Systems
Pepperl+Fuchs Bebco EPS Purge and Pressurization Systems
CoversBebco EPS 5500, 6500, 3000, 6000, 5000, EPV vents, manifolds
Pepperl+Fuchs Bebco EPS purge and pressurization systems: 5500 series (Type Z / Ex pzc, Division 2 or Zone 2/22, up to 250 ft³) and 6500 series (Ex pxb, Zone 1/21, up to 450 ft³).
- 5500 series
- Type Z / Ex pzc; Class I and II Division 2 or Zone 2/22
- 6500 series
- Ex pxb; Zone 1/21 to non-hazardous; up to SIL 2
- 5500 supply
- 100–240 V AC or 20–30 V DC
- 5500 housing
- 316 stainless steel, Type 4X / IP66
Availability and lead time confirmed on request
Overview
Pepperl+Fuchs Bebco EPS Purge and Pressurization Systems (5500, 6500, EPV vents): Model Code Guide
Pepperl+Fuchs Bebco EPS purge and pressurization systems keep a protected enclosure at positive pressure so general-purpose equipment can run inside it in a hazardous area. The 5500 series covers Division 2 or Zone 2/22 (Type Z / Ex pzc) and the 6500 series covers Zone 1/21 (Ex pxb). A complete system is a control unit, a manifold valve and an EPV vent. We can supply control units, vents and manifolds. HKXYTECH is an independent supplier and every unit is 100% original and brand-new. Lead time is quoted per inquiry. We ship worldwide by DHL, UPS or FedEx air express or by sea freight, accept payment by T/T (your local currency is also supported) and reply to every inquiry within 24 hours.
How the 5500 control unit code reads (t167146 p. 6)
| 5500 | Series 5500, Type Z & Ex pz, Zone 2 or 22, NEC Class I or II Division 2 |
|---|---|
| SS | Housing: 316 stainless steel |
| E / I | Mounting: E = external; I = internal |
| VAC / VDC | Supply: 100–240 V AC or 20–30 V DC |
| PSC / PBC / PSH / PNO | Power wiring entry: (3) M20 stainless glands; (3) M20 nickel-plated glands; (3) 1/2" NPTF stainless conduit entries; none |
| LSC / LBC / LNO | Low-voltage wiring entry: (3) M12 stainless glands; (3) M12 nickel-plated glands; none |
| Matching parts | Vent EPV-5500-**-***; manifold 5500-MAN-EX01-* (ATEX/IECEx) or 5500-MAN-CDUL-* (UL) |
Example: 5500-SS-E-VAC-PNO-LNO = 5500 series control unit, 316 stainless housing (SS), external mounting (E), 100–240 V AC supply (VAC), no power fittings (PNO), no low-voltage glands (LNO).
Example order codes
| 5500-SS-E-VDC-PNO-LNO | As above with 20–30 V DC supply |
|---|---|
| 5500-MAN-EXMI-24VDC | 5500 series manifold, ATEX/IECEx family (5500-MAN-EX…); the EXMI suffix is confirmed from the full code |
| 6500-01-PM01-PNO-LNO | 6500 series Ex pxb control unit (6500-01-…); option blocks confirmed from the nameplate |
Before you order
- A working system needs a matching control unit, manifold and vent. Send all three codes, the enclosure volume and the zone.
- Older or project codes such as 3003-…, 5000Q-…, 6000-…, EPV-6000-… and PG-… packages are not decoded in the documents we used. Send the nameplate code and we confirm the current equivalent before quoting.
Frequently asked questions
Can you ship the Pepperl+Fuchs Bebco EPS purge system to the Middle East, Central Asia or Africa?
Yes. We ship worldwide, including the Middle East, Central Asia and Africa, by DHL, UPS or FedEx air express or by sea freight. Lead time and freight for your destination are quoted per inquiry.
Is a vent always required?
Pepperl+Fuchs states that vents are required for all Ex pxb enclosures and for most Type Z enclosures. Order the EPV vent that matches the control unit series.
Which series do I need, 5500 or 6500?
The 5500 series is for Division 2 or Zone 2/22 (Type Z / Ex pzc) and enclosures up to 250 ft³. The 6500 series is for Zone 1/21 (Ex pxb) and enclosures up to 450 ft³, with SIL 2 capability.
Is the Pepperl+Fuchs Bebco EPS purge system original and brand-new?
Yes. We supply 100% original, brand-new units. HKXYTECH is an independent supplier and is not affiliated with the manufacturer.
Do you provide a test report or certificate of origin (COO)?
Tell us which documents you need when you send the inquiry. We confirm per order which documents can be supplied with the unit.
Do you have stock for an urgent or shutdown replacement?
Stock changes daily, so availability is confirmed per inquiry. Send the full order code from the nameplate and mark the inquiry urgent; we reply within 24 hours with availability and lead time.
What if my model is discontinued?
Send the full order code from the nameplate. If the exact configuration is no longer made, we check the current equivalent from the same manufacturer and confirm it with you before quoting.
What are your payment and shipping terms?
Payment by T/T (bank transfer); payment in your local currency is also supported. Shipping by DHL, UPS or FedEx air express, or by sea freight. Lead time is quoted per inquiry.
Related models
Order codes in this series
233 order codes from this series are collected on this page. Send the full code from the label or your parts list when you ask for a quote.
Show all 233 codes
1031-H-0-0242-AA-K-ADP3003-LPC-CK-50-96243003-LPS-CI-YZ-CK3003-LPS-CI-YZ-CK-KIT013003-LPS-CI-YZ-CK-KIT023003-LPS-CI-YZ-CK-MINIHELIC3003-LPS-CI-YZ-CK-PROTECH3003-LPS-CI-YZ-CK-VX3003-LPS-CI-YZ-HMB3003-LPS-CI-YZ-HMB-VX3003-LPS-CI-YZ-HMP-Y5142443003-LPS-CI-YZ-HMT3003-LPS-CI-YZ-HMT-VX3003-LPS-CI-YZ-HPM3003-LPS-CI-YZ-HPM-VX3003-LPS-CI-YZ-VML3003-LPS-CI-YZ-VML-KIT013003-LPS-CI-YZ-VML-KIT023003-LPS-CI-YZ-VML-VX3003-LPS-CI-YZ-VMP-Y5142453003-LPS-CI-YZ-VMR3003-LPS-CI-YZ-VMR-KIT013003-LPS-CI-YZ-VMR-VX3003-LPS-CI-YZ-VPM3003-LPS-CI-YZ-VPM-VX3003-WPS-CI-YZ-HMB3003-WPS-CI-YZ-HMB-VX3003-WPS-CI-YZ-HMT3003-WPS-CI-YZ-HMT-VX3003-WPS-CI-YZ-VML3003-WPS-CI-YZ-VML-KIT013003-WPS-CI-YZ-VML-VX3003-WPS-CI-YZ-VMR3003-WPS-CI-YZ-VMR-KIT013003-WPS-CI-YZ-VMR-VX3003-WPS-CI-YZ-WM3003-WPS-CI-YZ-WM-VX3003-WPSA-CI-YZ-HMB3003-WPSA-CI-YZ-HMB-240VAC3003-WPSA-CI-YZ-HMB-24VDC3003-WPSA-CI-YZ-HMB-VX3003-WPSA-CI-YZ-HMT3003-WPSA-CI-YZ-HMT-240VAC3003-WPSA-CI-YZ-HMT-24VDC3003-WPSA-CI-YZ-HMT-VX3003-WPSA-CI-YZ-HMT-VX-240VAC3003-WPSA-CI-YZ-HMT-VX-24VDC3003-WPSA-CI-YZ-VML3003-WPSA-CI-YZ-VML-240VAC3003-WPSA-CI-YZ-VML-24VDC3003-WPSA-CI-YZ-VML-VX3003-WPSA-CI-YZ-VML-VX-2203003-WPSA-CI-YZ-VML-VX-24VDC3003-WPSA-CI-YZ-VMR3003-WPSA-CI-YZ-VMR-220VAC3003-WPSA-CI-YZ-VMR-24VDC3003-WPSA-CI-YZ-VMR-VX3003-WPSA-CI-YZ-VMR-VX-24VDC3003-WPSA-CI-YZ-WM3003-WPSA-CI-YZ-WM-24VDC3003-WPSA-CI-YZ-WM-VX-24VDC5000Q-02-PY-O-115VAC5000Q-02-PY-O-230VAC5000Q-02-PY-O-24VDC5000Q-DV-08-13-115VAC-IECEx5000Q-DV-08-13-230VAC-IECEx5000Q-DV-08-13-24VDC-IECEx5000Q-DV-08-13-BR-115VAC-EX5000Q-DV-08-13-BR-230VAC-EX5000Q-DV-08-13-BR-230VAC-KOSHA5000Q-DV-08-13-BR-24VDC-EX5000Q-PRE-08-PA5000Q-PRE-08-PA-Z225500-ACC-RTK-015500-DEMOKIT-230VAC5500-MAN-CD01-120VAC5500-MAN-CD01-230VAC5500-MAN-CD01-24VDC5500-MAN-CDUL-120VAC5500-MAN-CDUL-230VAC5500-MAN-CDUL-24VDC5500-MAN-EX01-120VAC5500-MAN-EX01-230VAC5500-MAN-EX01-24VDC5500-MAN-EXHT-230VAC5500-MAN-EXMI-120VAC5500-MAN-EXMI-230VAC5500-MAN-EXMI-24VDC5500-SS-E-VAC-PBC-LBC5500-SS-E-VAC-PNO-LNO5500-SS-E-VAC-PSC-LSC5500-SS-E-VAC-PSH-LBC5500-SS-E-VAC-PSH-LSC5500-SS-E-VDC-PBC-LBC5500-SS-E-VDC-PNO-LNO5500-SS-E-VDC-PSC-LSC5500-SS-E-VDC-PSH-LBC5500-SS-E-VDC-PSH-LSC5500-SS-I-VAC-PNO-LNO5500-SS-I-VAC-PSH-LBC5500-SS-I-VDC-PBC-LBC5500-SS-I-VDC-PNO-LNO5500-SS-I-VDC-PSH-LBC6000-ACC-installation-2684696000-CBLA-ISB-0306000-CBLA-ISB-0506000-CBLA-ISB-1006000-CBLA-ISB-2006000-DCK-036000-DCK-046000-DV-S2-4AN-WH-AC6000-DV-S2-UN-CK-AC6000-DV-S2-UN-CK-DC6000-DV-S2-UN-WH-AC6000-DV-S2-UN-WH-AC-RH6000-DV-S2-UN-WH-DC6000-DV-S2-UN-XD-AC6000-DV-S2-UN-XD-DC6000-EXKIT-AC-016000-EXKIT-DC-016000-ISB-016000-JCK-016000-MAN-DV-016000-NV-S2-UN-CK-AC6000-NV-S2-UN-CK-DC6000-NV-S2-UN-WH-DC6000-NV-S2-UN-XD-AC6000-TEMP-016000-TSEN-016000-UIC-016500-01-EPCU-PNO-LNO6500-01-EXT1-BKT016500-01-EXT1-PNO-LNO6500-01-INT1-BKT016500-01-PM01-BKT016500-01-PM01-PNO-LNO6500-01-PM02-PLT6500-01-PM02-PNO-LNO6500-01-UIC-EXT6500-01-UIC-PM06500-CBLG-01-CBC6500-CBLG-01-CPC6500-CBLG-01-CSC6500-CBLG-01-LBC6500-CBLG-01-LPC6500-CBLG-01-LSC6500-CBLG-01-PBC6500-CBLG-01-PPC6500-CBLG-01-PSC6500-MAN-DV-016500-MAN-PV-01EPV-5500-AA-01EPV-5500-AA-02EPV-5500-AA-03EPV-5500-SS-01EPV-5500-SS-02EPV-5500-SS-03EPV-6000-AA-01EPV-6000-AA-02EPV-6000-AA-03EPV-6000-AA-04EPV-6000-AA-05EPV-6000-AA-06EPV-6000-SS-01EPV-6000-SS-02EPV-6000-SS-03EPV-6000-SS-04EPV-6000-SS-05EPV-6000-SS-06EPV-6500-AA-01EPV-6500-AA-03EPV-6500-AA-05EPV-6500-AA-07EPV-6500-AA-08EPV-6500-SS-01EPV-6500-SS-03EPV-6500-SS-05EPV-6500-SS-07EPV-6500-SS-08PG-BG-VORTEX-Y290334PG-C1D1-6000-Y285710PG-C1D1-6000-Y285711PG-C1D1-6000-Y287965PG-C1D1-6000-Y293176PG-C1D2-3003-Y296029PG-ENC-5000Q-Y261652PG-ENC-5000Q-Y262473PG-ENC-5000Q-Y292442PG-ENC-C1D1-Y288579PG-ENC-Z1G-6000-Y284295PG-ENC-Z1G-6000-Y292511PG-ENC-Z1G-Y284294PG-ENC-Z2G-5500-Y290225PG-IEC-SYS-Z2G-5000Q-Y283750PG-IEC-SYS-Z2G-5500-Y298882PG-MP-Y283771PG-PK-Z1G-6000-Y277261PG-SYS-C1D1-6000-Y279812PG-SYS-C1D1-6000-Y284137PG-SYS-C1D1-6000-Y284138PG-SYS-C1D1-6000-Y284139PG-SYS-C1D2-5500-Y299538PG-SYS-Z1G-6000-Y284080PG-SYS-Z1G-6000-Y288375PG-SYS-Z1G-6000-Y289504PG-SYS-Z1G-6000-Y290980PG-SYS-Z1G-6000-Y295962PG-SYS-Z1G-6000-Y296336PG-SYS-Z1G-6000-Y299097PG-SYS-Z1G-6000-Y913280PG-SYS-Z1G-6000-Y913281PG-SYS-Z1G-6000-Y913293PG-SYS-Z1G-6000-Y913294PG-SYS-Z1G-6000-Y913295PG-SYS-Z1G-6000-Y913465PG-SYS-Z1G-6500-Y296266PG-SYS-Z1GD-6000-Y298936PG-SYS-Z2G-3003-Y913071PG-SYS-Z2G-5000Q-Y238093PG-SYS-Z2G-5000Q-Y283770PG-SYS-Z2G-5000Q-Y285424PG-SYS-Z2G-5000Q-Y288047PG-SYS-Z2G-5000Q-Y288050PG-SYS-Z2G-5000Q-Y293359PG-SYS-Z2G-5500-Y281293PG-SYS-Z2G-5500-Y283777PG-SYS-Z2G-5500-Y285734PG-SYS-Z2G-5500-Y292514PG-SYS-Z2G-5500-Y294312PG-SYS-Z2G-5500-Y297456PG-SYS-Z2G-5500-Y297457PG-SYS-Z2G-6000-Y279092PG-Z2G-5500-Y282524
Source: Pepperl+Fuchs datasheet 5500 Series Control Unit, Type Z and Ex pzc (t167146_eng.pdf, 2025-06-18); Pepperl+Fuchs Type Z Purge and Pressurization Systems page (gp32695); Pepperl+Fuchs Ex pxb Purge and Pressurization Systems page (gp32704); Pepperl+Fuchs instruction manual 6500 series (tdoctb2w9b), marking section; Pepperl+Fuchs instruction manual 5500 series (tdoct6494c), marking section.
Specifications
| System | Control unit + manifold valve + EPV vent form a certified purge and pressurization system (t167146); vents are required for Ex pxb and most Type Z enclosures (P+F series pages) |
|---|---|
| Bebco EPS series overview | 7500 and 5500 series reduce the classification inside the enclosure from Division 2 to non-hazardous, so general industrial equipment can be used; 3000 and 1000 series reduce it from Division 1 to Division 2 and need Division 2 certified equipment inside (P+F Type Z page) |
| 5500 series | Type Z / Ex pzc; Class I and II Division 2 or Zone 2/22; enclosure volumes up to 250 ft³ (7.08 m³); ATEX, IECEx, cULus, NFPA 496, CCC; one unit certified for gas or dust |
| 5500 functions | Fully automatic purge, power and monitoring; 4 to 19 volume exchanges; 2 Pt100 RTD inputs for temperature alarm and control; 5 preset purge programs; bypass input; Automatic Rapid Exchange for temperature control and leak compensation |
| 5500 electrical | 100–240 V AC or 20–30 V DC; outputs K1 enclosure power SPST 6 A, K2 alarm SPDT 3 A, digital valve 5 A |
| 5500 housing | 316 stainless steel, Type 4X / IP66, 165 x 124 x 90 mm, about 2.7 kg; 1/8" NPTF pressure ports; certificate DEMKO 14 ATEX 1282X |
| 6500 series | Ex pxb; Zone 1/21 to non-hazardous; up to SIL 2 (IEC 61508); enclosure sizes up to 12.7 m³ (450 ft³); ATEX, IECEx, CCC, UKCA; AC or DC supply; intrinsically safe LCD touch pad; RS-485/HART and Bluetooth remote monitoring; dilution control for analyzers |
| 6500 parts | 6500-01-****-***-*** control unit; EPV-6500-**-** relief vent; 6500-MAN-DV-** manifold valve (6500 manual) |
Source: Pepperl+Fuchs datasheet 5500 Series Control Unit, Type Z and Ex pzc (t167146_eng.pdf, 2025-06-18); Pepperl+Fuchs Type Z Purge and Pressurization Systems page (gp32695); Pepperl+Fuchs Ex pxb Purge and Pressurization Systems page (gp32704); Pepperl+Fuchs instruction manual 6500 series (tdoctb2w9b), marking section; Pepperl+Fuchs instruction manual 5500 series (tdoct6494c), marking section. Confirm with the manufacturer datasheet before ordering.
Applications
The Bebco EPS 5500 control unit works with EPV vents and pneumatic solenoid valves or manual valves to form a certified purge and pressurization system for enclosures. It monitors enclosure pressure and leakage; on a loss of pressure it can open a solenoid valve to restore the set pressure and/or raise an alarm. Two RTD inputs let it alarm on or control enclosure temperature, for example by energizing a solenoid valve that displaces the air in the enclosure, or by switching cooling or heating.
Source: Pepperl+Fuchs datasheet t167146 (5500 series control unit), section Function. The 5500 series is certified for Class I, II / Div. 2 and Zone 2/22.
Documents
- DatasheetPDF · on request Request
- Operating manualPDF · on request Request
- Certificate copy (with order, where available)PDF · on request Request
Downloads will be added after the files have been checked.
Frequently paired with
Often quoted together with Pepperl+Fuchs Bebco EPS Purge and Pressurization Systems.