Illustration of the product type. Photos are sent with the quotation on request.
Pepperl+Fuchs K-System Isolated Barriers and Signal
CoversK-System (KFD2, KCD2, KFD0, KFU8, termination boards, Power Rail)
Pepperl+Fuchs K-System DIN-rail isolators: KFD2/KCD2 isolated barriers for intrinsically safe loops and signal conditioners for safe-area loops, KFD0 loop-powered devices, KFU8 universal-supply devices, termination boards and Power Rail.
Availability and lead time confirmed on request
Overview
Pepperl+Fuchs K-System Isolated Barriers and Signal Conditioners (KFD2, KCD2, KFD0, KFU8): Model Code Guide
The Pepperl+Fuchs K-System is a family of DIN-rail isolators. Its isolated barriers (Ex in the model code, for example KFD2-STC4-Ex1) protect intrinsically safe loops in hazardous areas. Its signal conditioners (no Ex, for example KFD2-STC4-1) isolate loops in the safe area. We can supply K-System isolators, termination boards and Power Rail parts. HKXYTECH is an independent supplier and every unit is 100% original and brand-new. Lead time is quoted per inquiry. We ship worldwide by DHL, UPS or FedEx air express or by sea freight, accept payment by T/T (your local currency is also supported) and reply to every inquiry within 24 hours.
How a K-System model code reads
| KF / KC | Housing: KF = 20 mm K-System housing; KC = 12.5 mm housing (for example KCD2-STC-Ex1) |
|---|---|
| D2 / D0 / U8 | Supply: D2 = 24 V DC via Power Rail or terminals; D0 = loop-powered, no separate supply; U8 = universal supply 20–90 V DC / 48–253 V AC |
| Function code | For example STC4 / STC = SMART transmitter power supply (AI); SCD / CD = current driver for positioners (AO); UT2 = universal temperature converter; RR = RTD converter; SR2 / SRA = switch amplifier with relay output (DI); ST2 / SOT2 = switch amplifier with transistor output (DI); SL2 / SD = solenoid driver (DO); VR4 = vibration pick-up; UFC = frequency converter with trip values |
| Ex1 / Ex2 / Ex4 | Isolated barrier with an intrinsically safe field circuit and 1, 2 or 4 channels |
| -1 / -2 (no Ex) | Signal conditioner for a non-hazardous field circuit with 1 or 2 channels (for example KFD2-STC4-1, KFD2-STC4-2) |
| Suffixes | For example .2O = one input, two outputs; .D = with control panel; .SP = spring terminals; -Y… = special version. Other suffixes such as .LK, .W, .B mark variants; check the exact code on the datasheet. |
Example: KFD2-STC4-Ex1 = K-System 20 mm housing (KF), 24 V DC via Power Rail (D2), SMART transmitter power supply (STC4), one intrinsically safe channel (Ex1): supplies a 2- or 3-wire HART transmitter in the hazardous area and outputs an isolated 0/4–20 mA signal, up to SIL 2.
Common K-System models by signal (application guide pp. 5–7)
| AI, 2-wire transmitters | KFD2-STC4-Ex1 (1 ch), KFD2-STC4-Ex2 (2 ch), KFD2-STC4-Ex1.2O (1 in / 2 out), KCD2-STC-Ex1 (12.5 mm); non-Ex: KFD2-STC4-1, KFD2-STC4-2, KFD2-CR4-1.2O |
|---|---|
| AO, positioners and I/P converters | KCD2-SCD-Ex1, KFD2-SCD-Ex1.LK, KFD2-SCD2-Ex2.LK, KFD2-CD-Ex1.32, KFD2-CD2-Ex2 |
| Temperature, mV, RTD | KFD2-UT2-Ex1, KFD2-UT2-Ex2, KFD2-RR-Ex1, KFD2-VR2-Ex1.50m; non-Ex: KFD2-UT2-1, KFD2-UT2-2 |
| DI, NAMUR or dry contact | KCD2-SR-Ex1.LB, KCD2-SR-Ex2, KFD2-SR2-Ex1.W, KFD2-SR2-Ex2.W, KFD2-SR2-Ex2.2S, KFD2-SRA-Ex4, KFD2-ST2-Ex2, KFD2-SOT2-Ex2 |
| DO, solenoid valves | KFD2-SL2-Ex1, KFD2-SL2-Ex1.B, KFD2-SL2-Ex2.B, KFD0-SD2-Ex1.1045, KFD0-SD2-Ex2.1045 (SIL 3) |
| Frequency and vibration | KFD2-VR4-Ex1.26 (vibration pick-up), KFD2-VR-Ex1.18, KFD2-UFC-Ex1.D (frequency with trip values) |
| Loop-powered | KFD0-SCS-Ex1.55, KFD0-CC-Ex1, KFD0-CS-Ex1.51P, KFD0-CS-Ex2.51P, KFD0-TR-Ex1 |
| Universal supply | KFU8-USC-1.D current/voltage converter with trip value |
| Power and wiring | UPR-03 Power Rail, KFD2-EB2.R4A.B power feed module, K-System termination boards, FSY cable connectors, KFD0-LC1 label carrier |
Before you order
- Ex and non-Ex versions of the same function are not interchangeable. Only a model with Ex in the code may be connected to an intrinsically safe field circuit.
- Check the number of channels, the supply (D2, D0 or U8) and suffixes such as .2O, .LK or -Y… against the nameplate before you order.
- For a termination board, send the full board code and the control system and I/O card it connects to.
Frequently asked questions
Can you ship the Pepperl+Fuchs K-System isolator to the Middle East, Central Asia or Africa?
Yes. We ship worldwide, including the Middle East, Central Asia and Africa, by DHL, UPS or FedEx air express or by sea freight. Lead time and freight for your destination are quoted per inquiry.
What is the difference between KFD2-STC4-Ex1 and KCD2-STC-Ex1?
Both are 1-channel SMART transmitter power supplies with 24 V DC supply via Power Rail and up to SIL 2. The KFD2-STC4-Ex1 has a 20 mm housing and also supplies 3-wire transmitters. The KCD2-STC-Ex1 has a 12.5 mm housing for 2-wire transmitters, and its output can be set by DIP switch to current source, current sink or voltage.
What do Ex1, Ex2 and a code without Ex mean?
Ex1, Ex2 and Ex4 mark an isolated barrier with 1, 2 or 4 intrinsically safe channels, for example KFD2-STC4-Ex2 with two channels. A code without Ex is a signal conditioner for non-hazardous loops, for example KFD2-STC4-1. Do not replace an Ex model with a non-Ex model.
Is the Pepperl+Fuchs K-System isolator original and brand-new?
Yes. We supply 100% original, brand-new units. HKXYTECH is an independent supplier and is not affiliated with the manufacturer.
Do you provide a test report or certificate of origin (COO)?
Tell us which documents you need when you send the inquiry. We confirm per order which documents can be supplied with the unit.
Do you have stock for an urgent or shutdown replacement?
Stock changes daily, so availability is confirmed per inquiry. Send the full order code from the nameplate and mark the inquiry urgent; we reply within 24 hours with availability and lead time.
What if my model is discontinued?
Send the full order code from the nameplate. If the exact configuration is no longer made, we check the current equivalent from the same manufacturer and confirm it with you before quoting.
What are your payment and shipping terms?
Payment by T/T (bank transfer); payment in your local currency is also supported. Shipping by DHL, UPS or FedEx air express, or by sea freight. Lead time is quoted per inquiry.
Related models
Order codes in this series
398 order codes from this series are collected on this page. Send the full code from the label or your parts list when you ask for a quote.
Show all 398 codes
KCD0-LGHKCD0-LGH.SPKCD0-RSH-1.1D.1KCD0-RSH-1.1E.1KCD0-SD-Ex1.1245KCD0-SD-Ex1.1245-ABKCD0-SD-Ex1.1245.SPKCD2-RR-Ex1KCD2-RR-Ex1-ABKCD2-RR-Ex1-Y1KCD2-RR-Ex1.SPKCD2-SCD-1KCD2-SCD-1.SPKCD2-SCD-Ex1KCD2-SCD-Ex1-ABKCD2-SCD-Ex1.HCKCD2-SCD-Ex1.HC.SPKCD2-SCD-Ex1.SPKCD2-SON-Ex1KCD2-SON-Ex1.R1KCD2-SON-Ex1.R2KCD2-SON-Ex1.R3KCD2-SON-Ex1.SPKCD2-SON-Ex2KCD2-SON-Ex2.R1KCD2-SON-Ex2.R2KCD2-SON-Ex2.R3KCD2-SON-Ex2.SPKCD2-SOT-1.LBKCD2-SOT-1.LB.SPKCD2-SOT-2KCD2-SOT-2.SPKCD2-SOT-Ex1.LBKCD2-SOT-Ex1.LB-ABKCD2-SOT-Ex1.LB.SPKCD2-SOT-Ex2KCD2-SOT-Ex2-ABKCD2-SOT-Ex2.SPKCD2-SR-1.LBKCD2-SR-1.LB.SPKCD2-SR-2KCD2-SR-2.SPKCD2-SR-Ex1.LBKCD2-SR-Ex1.LB-ABKCD2-SR-Ex1.LB.SPKCD2-SR-Ex2KCD2-SR-Ex2-ABKCD2-SR-Ex2-PARKCD2-SR-Ex2-Y1KCD2-SR-Ex2.SPKCD2-ST-1.LBKCD2-ST-1.LB.SPKCD2-ST-2KCD2-ST-2.SPKCD2-ST-Ex1.LBKCD2-ST-Ex1.LB.SPKCD2-ST-Ex2KCD2-ST-Ex2.SPKCD2-STC-1KCD2-STC-1.2OKCD2-STC-1.SPKCD2-STC-Ex1KCD2-STC-Ex1-ABKCD2-STC-Ex1.2OKCD2-STC-Ex1.2O-ABKCD2-STC-Ex1.2O.DEKCD2-STC-Ex1.ESKCD2-STC-Ex1.ES.SPKCD2-STC-Ex1.HCKCD2-STC-Ex1.HC.SPKCD2-STC-Ex1.SPKCD2-UT2-1KCD2-UT2-Ex1KFA4-SR2-Ex1.WKFA4-SR2-Ex1.W.LBKFA4-SR2-Ex2.WKFA4-SR2-Ex2.W-IFMKFA5-DU-Ex1.DKFA5-DWB-Ex1.DKFA5-ER-1.5KFA5-ER-1.6KFA5-ER-Ex1.W.LBKFA5-SOT2-Ex2KFA5-SR2-Ex1.WKFA5-SR2-Ex1.W-IFMKFA5-SR2-Ex1.W.LBKFA5-SR2-Ex1.W.LB-ABKFA5-SR2-Ex2.WKFA5-SR2-Ex2.W-ABKFA5-SR2-Ex2.W-IFMKFA5-SR2-Ex2.W.IRKFA6-DU-Ex1.DKFA6-DWB-Ex1.DKFA6-ER-1.5KFA6-ER-1.6KFA6-ER-1.W.LBKFA6-ER-2.W.LBKFA6-ER-Ex1.W.LBKFA6-SOT2-Ex2KFA6-SR-2.3LKFA6-SR-2.3L.FAKFA6-SR2-Ex1.WKFA6-SR2-Ex1.W-IFMKFA6-SR2-Ex1.W.LBKFA6-SR2-Ex1.W.LB-ABKFA6-SR2-Ex2.WKFA6-SR2-Ex2.W-ABKFA6-SR2-Ex2.W-IFMKFA6-SR2-Ex2.W.IRKFA6-STR-1.24.4KFA6-STR-1.24.500KFD0-CC-1KFD0-CC-Ex1KFD0-CS-1.50KFD0-CS-2.50KFD0-CS-2.51PKFD0-CS-Ex1.50PKFD0-CS-Ex1.51PKFD0-CS-Ex1.52KFD0-CS-Ex1.53KFD0-CS-Ex1.54KFD0-CS-Ex1.54-Y1KFD0-CS-Ex1.54-Y2KFD0-CS-Ex1.54-Y3KFD0-CS-Ex1.56KFD0-CS-Ex2.50PKFD0-CS-Ex2.51PKFD0-CS-Ex2.51P-Y107439KFD0-CS-Ex2.52KFD0-CS-Ex2.53KFD0-CS-Ex2.54KFD0-LGHKFD0-LGH-5TKFD0-LGH-GNKFD0-LGH-Y34868KFD0-LGH-Y39343KFD0-RO-2KFD0-RO-Ex2KFD0-RSH-1KFD0-RSH-1-Y2KFD0-RSH-1.1D.F1KFD0-RSH-1.1E.1KFD0-RSH-1.4S.PS2KFD0-SCS-1.55KFD0-SCS-Ex1.55KFD0-SCS-Ex1.55-FMKFD0-SD2-Ex1.10100KFD0-SD2-Ex1.1045KFD0-SD2-Ex1.1065KFD0-SD2-Ex1.1180KFD0-SD2-Ex2.1045KFD0-SD2-Ex2.1245KFD0-TR-1KFD0-TR-Ex1KFD0-TT-1KFD0-TT-Ex1KFD2-CD-1.32KFD2-CD-Ex1.32KFD2-CD-Ex1.32-1KFD2-CD-Ex1.32-10KFD2-CD-Ex1.32-12KFD2-CD-Ex1.32-13KFD2-CD-Ex1.32-15KFD2-CD-Ex1.32-2KFD2-CD-Ex1.32-21KFD2-CD-Ex1.32-3KFD2-CD-Ex1.32-5KFD2-CD-Ex1.32-6KFD2-CD-Ex1.32-8KFD2-CD-Ex1.32-9KFD2-CD2-Ex1KFD2-CD2-Ex2KFD2-CR4-1KFD2-CR4-1.2OKFD2-CR4-2KFD2-CRG2-1.DKFD2-CRG2-Ex1.DKFD2-DU-Ex1.DKFD2-DWB-1.DKFD2-DWB-Ex1.DKFD2-EB.R4A.B-Y44151KFD2-EB2KFD2-EB2.R4A.BKFD2-EB2.R4A.B.SPKFD2-EB2.SPKFD2-ELD-16KFD2-ELD-Ex16KFD2-ER-1.5KFD2-ER-1.6KFD2-ER-1.W.LBKFD2-ER-2.W.LBKFD2-ER-Ex1.W.LBKFD2-FF-Ex2.RS232KFD2-GS-1.2WKFD2-GU-1KFD2-GU-Ex1KFD2-GUT-1.DKFD2-GUT-Ex1.DKFD2-HLC-Ex1.DKFD2-HLC-Ex1.D.2WKFD2-HLC-Ex1.D.4SKFD2-PT2-Ex1KFD2-PT2-Ex1-1KFD2-PT2-Ex1-4KFD2-PT2-Ex1-5KFD2-PT2-Ex1-6-Y112844KFD2-PT2-Ex1-Y98312KFD2-RCI-Ex1KFD2-SCD-Ex1.LKKFD2-SCD2-1.LKKFD2-SCD2-2.LKKFD2-SCD2-Ex1-Y1KFD2-SCD2-Ex2-Y1KFD2-SH-Ex1KFD2-SH-Ex1.TKFD2-SH-Ex1.T.OPKFD2-SL-4KFD2-SL2-Ex1KFD2-SL2-Ex1.BKFD2-SL2-Ex1.LKKFD2-SL2-Ex1.LK-Y1KFD2-SL2-Ex1.LK.1045KFD2-SL2-Ex1.LK.1270KFD2-SL2-Ex2KFD2-SL2-Ex2.BKFD2-SOT2-Ex1.LBKFD2-SOT2-Ex1.LB-IFMKFD2-SOT2-Ex1.LB.IOKFD2-SOT2-Ex1.NKFD2-SOT2-Ex1.R1KFD2-SOT2-Ex2KFD2-SOT2-Ex2-IFMKFD2-SOT2-Ex2.IOKFD2-SOT2-Ex2.IO-Y181008KFD2-SOT3-Ex1.LBKFD2-SOT3-Ex1.LB.IOKFD2-SOT3-Ex2KFD2-SOT3-Ex2.IOKFD2-SOT3-Ex2.IO-Y1KFD2-SR2-2.2SKFD2-SR2-Ex1.WKFD2-SR2-Ex1.W-IFMKFD2-SR2-Ex1.W.LBKFD2-SR2-Ex2.2SKFD2-SR2-Ex2.WKFD2-SR2-Ex2.W-IFMKFD2-SR2-Ex2.W.SMKFD2-SR3-2.2SKFD2-SR3-Ex2.2SKFD2-SRA-Ex4KFD2-ST2-Ex1.LBKFD2-ST2-Ex1.LB-IFMKFD2-ST2-Ex2KFD2-ST2-Ex2-IFMKFD2-ST3-Ex1.LBKFD2-ST3-Ex2KFD2-STC3-Ex1KFD2-STC4-1KFD2-STC4-1-3KFD2-STC4-1.2OKFD2-STC4-1.2O-3KFD2-STC4-2KFD2-STC4-2-3KFD2-STC4-Ex1-Y1KFD2-STC4-Ex1-Y2KFD2-STC4-Ex1-Y912993KFD2-STC4-Ex1.2OKFD2-STC4-Ex1.2O-Y1KFD2-STC4-Ex1.2O.HKFD2-STC4-Ex1.ESKFD2-STC4-Ex1.HKFD2-STC4-Ex2KFD2-STC4-Ex2-ABKFD2-STC4-Ex2-Y1KFD2-STC4-Ex2-Y229428KFD2-STC5-2KFD2-STC5-Ex1.2O.HKFD2-STC5-Ex2KFD2-STV3-Ex1-1KFD2-STV3-Ex1-2KFD2-STV4-1-1KFD2-STV4-2-1KFD2-STV4-Ex1-1KFD2-STV4-Ex1-1-Y1KFD2-STV4-Ex1-2KFD2-STV4-Ex1.2O-1KFD2-STV4-Ex1.2O-2KFD2-STV4-Ex2-2KFD2-UFC-1.DKFD2-UFC-Ex1.DKFD2-UFC-Ex1.D-ABKFD2-UFT-2.DKFD2-UFT-Ex2.DKFD2-USC-1.DKFD2-UT2-1KFD2-UT2-1-1KFD2-UT2-1-1-PARKFD2-UT2-1-PARKFD2-UT2-2KFD2-UT2-2-1KFD2-UT2-2-1-PARKFD2-UT2-2-PARKFD2-UT2-Ex1KFD2-UT2-Ex1-1KFD2-UT2-Ex1-1-PARKFD2-UT2-Ex1-ABKFD2-UT2-Ex1-PARKFD2-UT2-Ex2KFD2-UT2-Ex2-1KFD2-UT2-Ex2-1-PARKFD2-UT2-Ex2-PARKFD2-VM-Ex1.35.LKFD2-VR-Ex1.12KFD2-VR-Ex1.18KFD2-VR-Ex1.19KFD2-VR-Ex1.19-Y109129KFD2-VR2-Ex1.500MKFD2-VR2-Ex1.50MKFD2-WAC2-1.DKFD2-WAC2-Ex1.DKFD2-WAC2-Ex1.D-Y1KFU8-CRG2-1.DKFU8-CRG2-1.D-TECSISKFU8-CRG2-Ex1.DKFU8-DWB-1.DKFU8-GUT-1.DKFU8-GUT-Ex1.DKFU8-SR-1.3L.VKFU8-UFC-1.DKFU8-UFC-Ex1.DKFU8-UFC-Ex1.D-ABKFU8-UFT-2.DKFU8-UFT-Ex2.DKFU8-USC-1.DKFU8-VCR-1MB-FO-FBM201-BPAIMB-FO-FBM201-BPAI-DMB-FO-FBM201-BPAI-D-Y1MB-FO-FBM201-BPAI-FDMB-FO-FBM201-BPAI-FD-DMB-FO-FBM201-BPTIMB-FO-FBM201-BPTI-DMB-FO-FBM201-BPTI-D-Y1MB-FO-FBM204-BPAIOMB-FO-FBM204-BPAIO-DMB-FO-FBM204-BPAIO-FDMB-FO-FBM204-BPAIO-FD-DMB-FO-FBM204-BPTIOMB-FO-FBM204-BPTIO-DMB-FO-FBM204-BPTIO-FDMB-FO-FBM204-BPTIO-FD-DMB-FO-FBM205-BPAIO-FD-R-Y1MB-FO-FBM207B-BPDI-FDMB-FO-FBM207B-BPDI-FD-NExMB-FO-FBM207B-BPDI-FD-Y1MB-FO-FBM211-BPAIMB-FO-FBM211-BPAI-3WMB-FO-FBM211-BPAI-NExMB-FO-FBM211-BPTIMB-FO-FBM214-BPHIMB-FO-FBM214-BPHI-DMB-FO-FBM214-BPHI-D-NExMB-FO-FBM214-BPHI-FDMB-FO-FBM214-BPHI-FD-DMB-FO-FBM214-BPHI-FD-D-NExMB-FO-FBM215-BPHO-FDMB-FO-FBM215-BPHO-FD-DMB-FO-FBM215-BPHO-FD-D-NExMB-FO-FBM215-BPHO-FD-NExMB-FO-FBM216-BPHI-FD-RMB-FO-FBM216-BPHI-RMB-FO-FBM217-BPDI-FDMB-FO-FBM217-BPDI-FD-NExMB-FO-FBM218-BPHO-FD-RMB-FO-FBM237-BPAOMB-FO-FBM237-BPAO-FDMB-FO-FBM237-BPAO-FD-RMB-FO-FBM237-BPAO-FD-Y1MB-FO-FBM237-BPAO-RMB-FO-FBM241C-BPDIOMB-FO-FBM241C-BPDIO-FDMB-FO-FBM241C-BPDIO-FD-NExMB-FO-FBM241C-BPDIO-FD-Y1MB-FO-FBM241C-BPDIO-NExMB-FO-FBM242-BPDOMB-FO-FBM242-BPDO-FDMB-FO-FBM242-BPDO-NExUPR-03UPR-03-ABUPR-03-MUPR-03-SUPR-03-S-ABUPR-03-S-DIN-SOLUPR-03-S-INSERT-SOLUPR-03-S-SOLUPR-03-SOLUPR-05UPR-05-S
Source: Pepperl+Fuchs KF series isolated barrier application guide (Chinese edition); Pepperl+Fuchs manual K-System Isolators and Termination Boards (2017-03); Pepperl+Fuchs datasheet KFD2-STC4-Ex1 SMART Transmitter Power Supply (283672_eng.pdf); Pepperl+Fuchs datasheet KCD2-STC-Ex1 SMART Transmitter Power Supply (70150439_eng.pdf); Pepperl+Fuchs product page KFD2-STC4-Ex1; Pepperl+Fuchs manuals KF**-USC-1.D (tdoct0969c) and KF**-UFC-(Ex)1.D (tdoct0119g): D2 / U8 supply versions.
Specifications
| Device groups | Isolated barriers for intrinsically safe circuits in hazardous areas; signal conditioners for isolation in non-intrinsically safe applications (manual p. 7) |
|---|---|
| Housing | KF devices 20 mm wide (manual p. 8); KCD2 devices 12.5 mm wide (KCD2-STC-Ex1 datasheet) |
| Supply | KFD2 / KCD2: 24 V DC via Power Rail or terminals (KFD2-STC4-Ex1: 20–35 V DC; KCD2-STC-Ex1: 19–30 V DC); KFD0: loop-powered; KFU8: 20–90 V DC / 48–253 V AC |
| Signals covered | AI 4–20 mA with HART, AO to positioners and I/P converters, thermocouple / RTD / mV, NAMUR and dry-contact DI, solenoid-valve DO, frequency and vibration pick-up (application guide pp. 5–7) |
| Functional safety | Many models up to SIL 2; some solenoid drivers up to SIL 3 (application guide p. 5) |
| Example data, KFD2-STC4-Ex1 | 1 channel; input 2- and 3-wire SMART transmitters; output 0/4–20 mA, load 0–800 Ω; HART test sockets; ATEX BAS 99 ATEX 7060 X; 20 × 124 × 115 mm, housing type B2 |
| Termination boards | For KF isolators, 4, 8, 16 or 32 slots, redundant and fused power supply, fault monitoring; FSY cable connectors with 2 to 6 conductors (manual p. 9) |
| Power Rail | UPR-03 rail, 2 m long, carries 70–80 isolators and the collective fault signal; KFD2-EB2.R4A.B redundant power feed module, 24 V DC / 4 A (application guide p. 7) |
Source: Pepperl+Fuchs KF series isolated barrier application guide (Chinese edition); Pepperl+Fuchs manual K-System Isolators and Termination Boards (2017-03); Pepperl+Fuchs datasheet KFD2-STC4-Ex1 SMART Transmitter Power Supply (283672_eng.pdf); Pepperl+Fuchs datasheet KCD2-STC-Ex1 SMART Transmitter Power Supply (70150439_eng.pdf); Pepperl+Fuchs product page KFD2-STC4-Ex1; Pepperl+Fuchs manuals KF**-USC-1.D (tdoct0969c) and KF**-UFC-(Ex)1.D (tdoct0119g): D2 / U8 supply versions. Confirm with the manufacturer datasheet before ordering.
Documents
- DatasheetPDF · on request Request
- Operating manualPDF · on request Request
- Certificate copy (with order, where available)PDF · on request Request
Downloads will be added after the files have been checked.
Frequently paired with
Often quoted together with Pepperl+Fuchs K-System Isolated Barriers and Signal Conditioners.