Pepperl+Fuchs KFD2-SCD2-Ex2.LK SMART Current Driver
ModelKFD2-SCD2-Ex2.LK
SMART current driver, 2-channel isolated barrier for I/P converters and valve positioners. Input: 4–20 mA (control side), limited to approx. 30 mA; output: 4–20 mA, load 100–650 Ω.
- Input
- 4–20 mA (control side), limited to approx. 30 mA
- Output
- 4–20 mA, load 100–650 Ω
- Line fault detection
- Lead breakage and short circuit
- Supply
- 19–30 V DC via Power Rail or terminals 14+, 15-
Availability and lead time confirmed on request
Overview
Pepperl+Fuchs KFD2-SCD2-Ex2.LK SMART Current Driver, 2-Channel Isolated Barrier
Description of Pepperl+Fuchs KFD2-SCD2-Ex2.LK SMART Current Driver, 2-Channel Isolated Barrier
-
Smart current driver – 20mm
-
This isolated barrier is used for intrinsic safety applications. It drives SMART I/P converters, electrical valves, and positioners in hazardous areas.
-
Digital signals are superimposed on the analog values at the field or control side and are transferred bi-directionally.
-
Current transferred across the DC/DC converter is repeated at terminals 1, 2 and 4, 5.
-
An open and shorted field circuit presents a high input impedance to the control side to allow line fault detection by control system.
-
If the loop resistance for the digital communication is too low, an internal resistor of 250Ω between terminals 8, 9 and 11, 12 is available, which may be used as the HART communication resistor.
-
Sockets for the connection of a HART communicator are integrated into the terminals of the device.
-
A unique collective error messaging feature is available when used with the Power Rail system.
Technical specification of Pepperl+Fuchs KFD2-SCD2-Ex2.LK SMART Current Driver, 2-Channel Isolated Barrier
Supply voltage: 10-35V d.c.
Power consumption: 1.8W at 20mA
Input/Output: Analogue output
No. of Channels: 2
Output:
Current: 4-20mA
Load: 100-700Ω
Voltage: ≥14V at 20mA
Input:
Voltage drop: Approx. 4V or internal resistance 200Ω at 20mA
Input resistance: >100kΩ when wiring resistance in the field
<50Ω or >16V (equivalent to 800Ω at 20mA
Current: 4-20mA limited to approx. 25mA
(or the output current if less)
Ambient temperature: -20 to +60°C
Protection rating: IP20
Mounting: 35mm DIN rail or panel mount
Dimensions: w20 x h124 x d115mm
Features
-
SMART Current Driver KFD2-SCD2-Ex2.LK
-
2-channel isolated barrier
-
24 V DC supply (Power Rail)
-
Current output up to 700 AZ© load
-
HART I/P and valve positioner
-
Line fault detection (LFD)
-
Accuracy 0.05 %
-
Terminal blocks with test sockets
-
Up to SIL2 acc. to IEC 61508
Specifications
| Function | SMART current driver, 2-channel isolated barrier for I/P converters and valve positioners |
|---|---|
| Input | 4–20 mA (control side), limited to approx. 30 mA |
| Output | 4–20 mA, load 100–650 Ω |
| Line fault detection | Lead breakage and short circuit |
| Supply | 19–30 V DC via Power Rail or terminals 14+, 15- |
| Accuracy | < 0.1 % of full scale |
| Functional safety | SIL 2 (SC 3) |
| Ambient temperature | -40 to 70 °C |
| Ex certificate | BAS 00 ATEX 7240 X |
Source: Pepperl+Fuchs product page and data sheet KFD2-SCD2-Ex2.LK. Confirm with the manufacturer datasheet before ordering.
Documents
- DatasheetPDF · on request Request
- Operating manualPDF · on request Request
- Certificate copy (with order, where available)PDF · on request Request
Downloads will be added after the files have been checked.
Same series
Other models in the same family as Pepperl+Fuchs KFD2-SCD2-Ex2.LK.
Accessories and spares
Parts, licences and services made for Pepperl+Fuchs KFD2-SCD2-Ex2.LK.
Frequently paired with