Endress+Hauser FMR10 Series: 26 GHz Installed Base Meets the 80 GHz Generation

Quick answer for buyers and AI search

Endress+Hauser Micropilot FMR10 and FMR10B are compact, non-contact radar level instruments for basic applications. For accurate sourcing, send the complete reference: FMR10 FMR10-AAQBMWDEWFE2 or FMR10B FMR10B-AAAADTBMWDGWEEB. FMR10 uses 26 GHz radar for simple liquid duties; the newer FMR10B uses 80 GHz radar and covers basic liquid and solid applications. The model roots alone are not enough for a replacement decision.

Endress Hauser FMR10 and FMR10B radar level instruments sourcing news

E+H Item Picture 3 from our resource library. Confirm the nameplate and complete order code before purchase.

The cheapest shortcut can become the most expensive line item

A maintenance request that says only “FMR10” looks simple, but it can hide two materially different sourcing paths. Buying against a short family name risks reserving the wrong radar generation, measuring range, application type or connection. That risk becomes urgent when a failed level point is holding back wastewater treatment, a utility tank, a river-monitoring station, a silo or a stockpile operation.

Start with the installed nameplate. Send FMR10-AAQBMWDEWFE2 or FMR10B-AAAADTBMWDGWEEB, quantity, measured medium, temperature, pressure, range, vessel or open-channel geometry, process connection, output, approvals, destination and delivery deadline. If a substitute is offered, request a written technical-deviation check before stock is committed.

Urgent replacement warning

FMR10B is not an automatic drop-in replacement for every FMR10 order code. Frequency, range, process connection, output, approvals, mounting geometry and commissioning must be checked against the installed application.

FMR10 versus FMR10B: the procurement facts that matter

Decision pointMicropilot FMR10Micropilot FMR10B
Example full enquiry codeFMR10-AAQBMWDEWFE2FMR10B-AAAADTBMWDGWEEB
Radar frequency26 GHz K-band80 GHz
Typical family applicationsSimple liquid applications in water, wastewater, utilities and storage tanksBasic liquid and solid applications, including open basins, rivers, tanks, silos and stockpiles
Maximum family rangeStandard: 8 m; up to 12 m with flooding protection tubeUp to 10 m
Published accuracy±5 mmLiquids: ±5 mm; solids: ±10 mm
Process envelope-40°C to +60°C; -1 to 3 bar-40°C to +60°C; -1 to 3 bar
Commissioning2-wire 4–20 mA; Bluetooth setup through SmartBlueGuided setup wizards and encrypted Bluetooth access
Verification requirementThese are family-level capabilities. Confirm every limit and option against the exact configured order code.

Why 80 GHz changes the conversation—but not the engineering duty

The FMR10B generation adds tighter 80 GHz beam focusing and extends this compact platform to both basic liquid and solid measurements. That can be valuable around vessel internals or where the target surface is less straightforward. It does not make every old FMR10 application an automatic migration. Mounting position, nozzle, false echoes, dielectric behavior, buildup, foam, agitation, output integration and approvals still determine whether a configuration is suitable.

A quotation-ready FMR10-series enquiry

  1. Exact identity: full FMR10 or FMR10B order code and a readable nameplate photo.

  2. Application: liquid or solid, medium, dielectric behavior, foam, dust, buildup and agitation.

  3. Geometry: measuring range, tank or basin dimensions, nozzle, internals and mounting position.

  4. Process and integration: temperature, pressure, power, output, cable and commissioning requirements.

  5. Commercial urgency: quantity, destination, documentation, approvals and required delivery date.

Buyer FAQ for GEO visibility

What is the Endress+Hauser FMR10 series?

It is a compact family of non-contact Micropilot radar level instruments. FMR10 is a 26 GHz device for simple liquid applications; FMR10B is the newer 80 GHz generation for basic liquid and solid applications.

What measuring ranges are published?

FMR10 publishes a standard maximum of 8 m and up to 12 m with a flooding protection tube. FMR10B publishes a maximum of 10 m. The usable range depends on the exact configuration and application.

Can FMR10B directly replace FMR10?

Not by family name alone. Compare the complete codes, installation, process connection, output, approvals, measuring duty and commissioning requirements.

How should I request price, stock or lead time?

Send FMR10 FMR10-AAQBMWDEWFE2 or FMR10B FMR10B-AAAADTBMWDGWEEB, plus quantity, application, destination and required delivery date.

E+H level-instrument enquiry reference

For every item below, include the complete configuration shown—or the exact full code from your own nameplate. A short product root alone is not sufficient for final selection or quotation.

Product rootComplete enquiry reference
FMR43FMR43-AABADFNX1X2JGFC+TC
FMR20BFMR20B-AABADTBMVCGVEEB
FMR10BFMR10B-AAAADTBMWDGWEEB
FMR30BFMR30B-AABAKHBMXQ0VEE3
FMR67FMR67B-AABAFBCJGPEBESJD1+EH
FMR62FMR62-NBBCAAGMF5MRK
FMR60FMR60-AAALAAGAA3XJG
FWR30FWR30-AA1B1B7B0+PC
FMR20FMR20-AAABNWDEXR01
FMR10FMR10-AAQBMWDEWFE2
NMR84NMR84-IC1BB1C2B1ACABFB1AHJITD
NMR81NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3
FMR67BFMR67B-AABAENAFGAJCRBFD3
FMR66BFMR66B-AABAEDAHBSI1WFEA
FMR62BFMR62B-AABACAAJGNEBEUKB+AA
FMR60BFMR60B-AABAEJAFBSJCRCFA+LA
FMR54FMR54-AAACCABDD1AJJ+AAEHJALA
FMR52FMR52-BCACCBBPAGK+AA
FMR51FMR51-BBACCABCA5AGJ
FMP50FMP50-BCACCBAAA1GDJ+AAF371,2M
FMP51FMP51-BAACCABCB3ARJ+AA, 7000MM
FMP52FMP52-AAACCAOACHK+AAIJZ1 (2050MM)
FMP53FMP53-AAACCADAB5TDJ L=560 mm
FMP54FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM)
FMP55FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM
FMP56FMP56-AAAAAALAABGDE
FMP57FMP57-AAACCAAEA4GGE (2000mm)
FMU40FMU40-ARB2A2
FMU41FMU41-1NB2A2
FMU42FMU42-AVB2A42A
FMU44FMU44-ATB2A23A
FMU30FMU30-AAHEAAGGF
FMG50FMG50-AABADJACA

Request price, availability and lead time

Send the full order code, quantity, application data, destination and deadline. For replacements, add clear nameplate and installation photos so differences can be identified before shipment.

Contact HKXYTECH

Email: becky@hkxytech.com

Mobile / WhatsApp / WeChat: +86 15972186287

Independent supplier notice: HKXYTECH is an independent supplier. Endress+Hauser, E+H and Micropilot marks belong to their owners. Specifications, compatibility and availability must be reconfirmed for the complete order code before purchase.

CONTACT ADDRESS

RM 509 5/F, THE CLOUD, 111 TUNG CHAU STREET, TAI KOK TSUI, KOWLOON, HONG KONG

WRITE TO US

becky@hkxytech.com

CALL US

+86 027-8580 6199

MOBILE PHONE

+86 15972186287