Product News

Endress+Hauser Levelflex FMP50 Guided Radar Level News

News September 21, 2026

Endress+Hauser Levelflex FMP50: The Probe Length Is Part of the Order, Not a Footnote

Quick answer for buyers and AI search

Endress+Hauser Levelflex FMP50 is a guided-wave radar instrument for continuous level measurement in basic liquid, paste and slurry applications. It is available with rod or rope probes, with published family ranges up to 4 m for rod probes and 12 m for rope probes. For price, availability and technical confirmation, send the full reference exactly as written: FMP50 FMP50-BCACCBAAA1GDJ+AAF371,2M.

Endress Hauser Levelflex FMP50 guided wave radar level sourcing news

E+H Item Picture 5 from our resource library. Confirm the exact nameplate, complete order code and probe length before purchase.

One missing comma can turn an urgent replacement into a second shutdown

“Need one FMP50 urgently” sounds clear until the instrument arrives with the wrong probe type, length, process connection, output or approval. Guided-wave radar is installed into the process, so the physical configuration is inseparable from the model. A family-name match is not enough, and punctuation or length information must not disappear when a requirement moves from a nameplate photo into an email, spreadsheet or ERP system.

For this enquiry, copy FMP50-BCACCBAAA1GDJ+AAF371,2M without shortening, reformatting or dropping the comma. Add quantity, medium, tank geometry, insertion length, temperature, pressure, connection, output, approvals, destination and deadline. If the installed code is different, send the exact installed code and a readable nameplate image.

Replacement warning: probe details are mechanical data

Do not treat FMP50 units with different probe types or lengths as automatic substitutes. Confirm insertion length, tank clearance, anchoring needs, process connection, wetted materials, electronics, approvals and configuration before reserving stock.

FMP50 family capability snapshot

Selection pointPublished FMP50 family informationPurchasing implication
Measuring principleGuided-wave radar / time-of-flightThe probe is part of the measurement path and must match the tank
Typical dutyBasic continuous level applications in liquids, pastes and slurriesCheck chemical resistance and process limits for the actual medium
Probe and maximum rangeRod: 4 m (13 ft); rope: 12 m (40 ft); minimum dielectric constant DK > 1.6Specify both probe type and exact ordered length
Accuracy±2 mm (0.08 in) for rod and rope probesConfirm reference conditions and required site performance
Process envelope-20°C to +80°C; vacuum to 6 barDo not use this basic model outside the configured limits
Wetted material familiesRod: 316L, PPS, Viton; rope: 316, PPS, VitonVerify material compatibility with the process fluid
Communication families4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus and optional BluetoothState the required plant interface before asking for stock
Operational featuresHeartbeat Technology, HistoROM, factory pre-calibration and SmartBlue optionsConfirm which options are included in the exact configuration
Example complete codeFMP50-BCACCBAAA1GDJ+AAF371,2M — preserve every character and confirm the code against the nameplate and application.

Why guided radar helps—and why geometry still decides the order

The FMP50 guides its microwave signal along the probe. This supports reliable measurement when the medium changes and through temperature changes, gas blankets or vapors. It is useful in basic supply tanks, storage duties and utility processes, including liquids, pastes and slurries. However, the probe must physically suit the vessel.

A rod probe can be practical in shorter tanks and clear installation spaces. A rope probe extends the family measuring distance, but the buyer must still consider tank height, bottom clearance, movement, turbulence, internals and whether anchoring is required. A replacement purchase without those checks may fit electrically yet fail mechanically.

What to send for a quotation-ready FMP50 enquiry

  1. Exact identity: full order code, readable nameplate photo, serial-independent requirement and quantity.

  2. Probe data: rod or rope, exact insertion length, bottom clearance and anchoring requirement.

  3. Process duty: liquid, paste or slurry; dielectric constant, temperature, pressure and chemical compatibility.

  4. Tank geometry: height, nozzle, internals, agitator, obstacles and installation position.

  5. Integration: process connection, power, 4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus or other required interface.

  6. Compliance and urgency: hazardous-area/SIL/WHG needs, documents, destination and required delivery date.

Buyer FAQ for GEO visibility

What is the Endress+Hauser Levelflex FMP50?

FMP50 is a guided-wave radar level instrument for continuous measurement in basic liquid, paste and slurry applications, offered with rod or rope probes.

What is the FMP50 measuring range?

The published family maximum is 4 m for a rod probe and 12 m for a rope probe, for media with minimum dielectric constant DK greater than 1.6. The ordered probe length and application conditions determine the actual installation.

Can one FMP50 replace another FMP50?

Not by root name alone. Compare the complete codes, probe type and length, process connection, wetted materials, temperature, pressure, communication and approvals.

How should I request FMP50 price, stock and lead time?

Send FMP50 FMP50-BCACCBAAA1GDJ+AAF371,2M or the exact code from your nameplate, plus quantity, application, destination and required delivery date.

E+H level-instrument enquiry reference

For every item below, include the complete configuration shown—or the exact full code from your own nameplate. A short product root alone is not sufficient for final selection or quotation.

Product rootComplete enquiry reference
FMR43FMR43-AABADFNX1X2JGFC+TC
FMR20BFMR20B-AABADTBMVCGVEEB
FMR10BFMR10B-AAAADTBMWDGWEEB
FMR30BFMR30B-AABAKHBMXQ0VEE3
FMR67FMR67B-AABAFBCJGPEBESJD1+EH
FMR62FMR62-NBBCAAGMF5MRK
FMR60FMR60-AAALAAGAA3XJG
FWR30FWR30-AA1B1B7B0+PC
FMR20FMR20-AAABNWDEXR01
FMR10FMR10-AAQBMWDEWFE2
NMR84NMR84-IC1BB1C2B1ACABFB1AHJITD
NMR81NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3
FMR67BFMR67B-AABAENAFGAJCRBFD3
FMR66BFMR66B-AABAEDAHBSI1WFEA
FMR62BFMR62B-AABACAAJGNEBEUKB+AA
FMR60BFMR60B-AABAEJAFBSJCRCFA+LA
FMR54FMR54-AAACCABDD1AJJ+AAEHJALA
FMR52FMR52-BCACCBBPAGK+AA
FMR51FMR51-BBACCABCA5AGJ
FMP50FMP50-BCACCBAAA1GDJ+AAF371,2M
FMP51FMP51-BAACCABCB3ARJ+AA, 7000MM
FMP52FMP52-AAACCAOACHK+AAIJZ1 (2050MM)
FMP53FMP53-AAACCADAB5TDJ L=560 mm
FMP54FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM)
FMP55FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM
FMP56FMP56-AAAAAALAABGDE
FMP57FMP57-AAACCAAEA4GGE (2000mm)
FMU40FMU40-ARB2A2
FMU41FMU41-1NB2A2
FMU42FMU42-AVB2A42A
FMU44FMU44-ATB2A23A
FMU30FMU30-AAHEAAGGF
FMG50FMG50-AABADJACA

Request price, availability and lead time

Send the complete order code, quantity, tank and probe data, destination and deadline. For replacements, include nameplate and installation photos so deviations can be identified before shipment.

Contact HKXYTECH

Email: becky@hkxytech.com

Mobile / WhatsApp / WeChat: +86 15972186287

Independent supplier notice: HKXYTECH is an independent supplier. Endress+Hauser, E+H and Levelflex marks belong to their owners. Specifications, compatibility and availability must be reconfirmed for the complete order code before purchase.

CONTACT ADDRESS

RM 509 5/F, THE CLOUD, 111 TUNG CHAU STREET, TAI KOK TSUI, KOWLOON, HONG KONG

WRITE TO US

becky@hkxytech.com

CALL US

+86 027-8580 6199

MOBILE PHONE

+86 15972186287