Switch / proximity detector interface with line fault detection. Channels: Two; inputs: NAMUR proximity detectors (EN 60947-5-6) or switches; voltage applied to sensor: 7–9 V DC from 1 kΩ.

Channels
Two
Inputs
NAMUR proximity detectors (EN 60947-5-6) or switches
Voltage applied to sensor
7–9 V DC from 1 kΩ
Safe-area output
Two changeover relays

Availability and lead time confirmed on request

Overview

MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection

Brief Description of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection

MTL5516C Proximity Detector Interface 2-ch. Switch, LFD/phase reversal, input NAMUR, RO 2CO, safety voltage max. 10.5V, safety current max. 14mA, 20..35VDC, MTL
Model Code: MTL5516C

Product Details of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
The MTL5516C is a Switch/Proximity Detector Interface enables two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line-fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for each channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.
Inputs conforming to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR)
Two single-pole relays with changeover contacts

 
Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on the success of the MTL5000 series to bring the benefits of galvanic isolation with exceptional design and reliability.,II (I) GD (Ex ia) IIC,IECEx, ATEX (Baseefa) FM, CSA

Features
 
•   3-Port Isolation
•   High Packing density
•   Low power dissipation
•   Multi-channel I/O modules
•   Compatible with preceding MTL5000 series
•   Assessed for Functional safety IEC61508 applications
•   Required EX numbers and information displayed on cover where applicable

5500 Series IS Interface Units      MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
The MTL5500 series is the latest generation of MTL isolators. Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on the success of the MTL5000 series to bring the benefits of galvanic isolation with exceptional design and reliability.,II (I) GD (Ex ia) IIC,IECEx, ATEX (Baseefa) FM, CSA

PRODUCT LITERATURE of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection

Product Code Description
 Symbol denotes that the equipment is suitable for use in hazardous area applications.
 Symbol denotes that the product has been assessed for functional safety applications.
SM45-55-AI  FSM Safety Manual – Analogue Input Modules
SM45-55-AO  FSM Safety Manual – Analogue Output Modules
SM45-55-BI  FSM Safety Manual – Binary Input Modules
SM45-55-MMI  FSM Safety Manual – Machine Monitor Interfaces
SM45-55-SAD  FSM Safety Manual – Solenoid / Alarm Driver Modules
 
1. Intro of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
INA4500 MTL4500/4600 range Instructions for Safe Use
INM4500/4600 MTL4500/4600 range Instruction Manual
MTL4500-5500-ACC Backplanes, Enclosures & Accessories
MTL4500-5500-CS Common Specifications
MTL4500-5500-DS MTL4500-5500 range Data Set
 
2. Digital Input of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4501-SR   1ch DI failsafe solid-state output + LFD alarm
MTL4504   1ch DI relay output + LFD alarm + phase reversal
MTL4510  4ch DI solid-state output
MTL4510B  4ch DI multifunction solid-state output
MTL4511   1ch DI relay output
MTL4513  2ch DI solid-state output
MTL4514D   1ch switch/prox input, dual output relay
MTL4514_B   1ch DI relay output + LFD alarm
MTL4516   2ch DI relay output
MTL4516C   2ch DI with changeover relay output
MTL4517   2ch DI relay output + LFD alarm
 
3. Digital Output of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4521   Loop powered solenoid driver
MTL4521L   loop powered solenoid driver IIC
MTL4523   Solenoid driver with LFD
MTL4523L   Loop powered solenoid driver + LFD
MTL4523R   Solenoid driver with LFD
MTL4523V-VL   Solenoid/Alarm driver with voltage control
MTL4524   Switch operated solenoid driver
MTL4524S   Switch operated solenoid driver, 24V override
MTL4525   Switch operated solenoid driver low power
MTL4526  2ch switch operated relay
 
4. Analogue Input of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4541   1ch 2/3 wire Transmitter repeater
MTL4541A  1ch Transmitter repeater, passive input
MTL4541AS  1ch Transmitter repeater, passive input, current sink
MTL4541B   MTL4041B replacement
MTL4541P  MTL4041P replacement
MTL4541S   1ch 2/3 wire Transmitter repeater, current sink
MTL4541T  2/3 wire Transmitter repeater
MTL4544   2ch 2/3 wire Transmitter repeater
MTL4544A  2ch Transmitter repeater, passive input
MTL4544AS  2ch Transmitter repeater, passive input, current sink
MTL4544B  MTL4044 replacement
MTL4544D   2/3 wire transmitter repeater, dual output
MTL4544S   2ch 2/3 transmitter repeater, current sink
 
5. Analogue Output of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4546   1ch 4-20mA smart isolating driver + LFD
MTL4546C   1ch 4-20mA smart isolating driver + oc LFD
MTL4546S  1ch 4-20mA HART isolating driver + LFD
MTL4546Y   1ch 4-20mA smart isolating driver + oc LFD
MTL4549   2ch 4-20mA smart isolating driver + LFD
MTL4549C   2ch 4-20mA smart isolating driver + oc LFD
MTL4549Y   2ch 4-20mA smart isolating driver + oc LFD
 
6. Temperature Input of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4573  1ch Temperature converter, RTD / THC
MTL4575  1ch Temperature converter, RTD / THC with alarm
MTL4576-RTD  2ch Temperature converter, RTD
MTL4576-THC  2ch Temperature converter, THC
MTL4581  1ch mV/THC isolator for low-level signals
MTL4582B   1ch resistance isolator to repeat RTD signals
 
7. Pulse and Vibration of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4531   1ch vibration probe interface
MTL4532  1ch pulse isolator, digital or analogue output
 
8. Fire and Smoke of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4561   2ch loop-powered, for fire and smoke detectors
 
9. General of MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection
 
MTL4599 Dummy isolator
MTL4599N General purpose feed-through module

MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection

MTL5000 Function MTL5500 Notes
MTL5011B 1ch, changeover relay output MTL5511
MTL5012 1ch, solid-state output Use 1ch of MTL5513
MTL5012S 1ch, solid-state output, UE1 special No replacement
MTL5014 1ch, c/o relay output, LFD relay MTL5514/14D MTL5514 does not provide 1in 2out
function. MTL5514D with 1in 2out
available Q1 2014
MTL5015 2ch, solid-state output MTL5513 Common connection on haz side,
max frequency response 500Hz
MTL5016 2ch, n/o relay output MTL5516C
MTL5017 2ch, n/o relay output, LFD relay MTL5517 LFD relay energises on alarm
MTL5018 2ch, changeover relay output MTL5516C Common connection on haz side
MTL5018ac 2ch, changeover relay output, ac power Continues as MTL5018ac.
Alternative option: MTL5516C fitted
with MPA5500 ac adaptor
MTL5021 Loop powered, IIC, (12.85V, 45mA, cl 45mA) MTL5521 (12.8V, 48mA, cl 48mA)
MTL5022 Loop powered, IIB, (12.9V, 60mA, cl 60mA) MTL5522 (9.9V, 70mA, cl 70mA)
MTL5023 Logic ctrl, lfd, phase,(12.85V, 45mA, cl 45mA) MTL5523 (12.8V, 48mA, cl 48mA)
MTL5024 Logic ctrl, phase, (12.85V, 45mA, cl 45mA) MTL5524 (12.8V, 48mA, cl 48mA)
MTL5025 Loop powered, IIC, (8.6V, 45mA, cl 45mA) MTL5525 (7V, 48mA, cl 48mA), lower Io
MTL5031 Vibration transducer interface MTL5531 Now Velomitor compatible
MTL5032 Pulse isolator MTL5532 Now with 4-20mA output and alarm
MTL5040 Loop isolator Use MTL5541 and MTL5546Y
MTL5041 For 2-wire transmitters MTL5541
MTL5042 For 2- or 3-wire txs, smart MTL5541
MTL5043 Dual output for 2-wire smart txs MTL5544D No current sink o/p. Passive Tx input
MTL5044 Two channel for 2-wire txs MTL5544 Now with passive Tx inputs
MTL5045 Isolating driver MTL5546Y Smart only versions
MTL5046 Smart isolating driver with LFD MTL5546
MTL5049 Two channel isolating driver MTL5549Y Smart only versions
MTL5051 Serial-data comms isolator Continues as MTL5051 model
MTL5053 Fieldbus isolator/power supply Discontinued
MTL5061 Fire/smoke detector interface MTL5561
MTL5073 Temperature converter MTL5575 Now with trip alarm
MTL5074 Temperature converter MTL5575 Now with trip alarm
MTL5081 mV/THC isolator MTL5581
MTL5082 Resistance isolator MTL5582
MTL5113P Failsafe sw/prox interface MTL5501-SR
MTL5314 Trip amplifier Continues as MTL5314 model
MTL5344 Repeater power supply Discontinued
MTL5349 Isolating driver Discontinued
MTL5991 24V power supply Continues as MTL5991 model
MTL5995 Fieldbus power supply Convert to F10X range product
 

 

MTL5516C Switch/Proximity Detector Interface, 2-Channel, Line Fault Detection

       

Specifications

FunctionSwitch / proximity detector interface with line fault detection
ChannelsTwo
InputsNAMUR proximity detectors (EN 60947-5-6) or switches
Voltage applied to sensor7–9 V DC from 1 kΩ
Safe-area outputTwo changeover relays
Contact rating250 V AC, 2 A (cos φ > 0.7); 40 V DC, 2 A resistive
Response time10 ms maximum
Current consumption35 mA at 24 V
Safety description (each channel)Uo = 10.5 V, Io = 14 mA, Po = 37 mW, Um = 253 V rms or DC

Source: MTL (Eaton) data sheet MTL4516/C – MTL5516C, EPSx516/C Rev 6 (mtl-inst.com). Confirm with the manufacturer datasheet before ordering.

Documents

  • DatasheetPDF · on request Request
  • Operating manualPDF · on request Request
  • Certificate copy (with order, where available)PDF · on request Request

Downloads will be added after the files have been checked.