MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
Overview of MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL 7700 Intrinsically Safe Barrier
DIN-rail zener barriers limit the amount of energy transferred across the barrier to a level that cannot ignite flammable atmospheres
Description of MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
The MTL7700 Intrinsically Safe Barriers are 1- or 2-channel DIN-rail mounted shunt-diode safety barriers that use intrinsically safe explosion-protection techniques to pass electrical signals between safe and hazardous areas, while limiting transferred energy to a level that cannot ignite flammable atmospheres. Connected in series with wiring entering any hazardous area on process plant, MTL7700 Series barriers prevent explosions in all normally occurring explosive atmospheres – including mixtures of air with flammable gases, vapors, dusts and fibers – if a fault or faults develop in the safe area.
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
The MTL7700 is a DIN rail mounting barrier providing quick and easy installation without the need for special hardware. Removable terminals are used for ease of installation, maintenance and for providing a loop disconnect by simply unplugging the terminals from the side of the module. Wire entry is also angled to assist wiring within limited space enclosures. MTL7700 barriers clamp simply and securely onto standard T-section DIN rail, simultaneously making a reliable IS earth connection. For applications where field power is required for switch inputs or 2-wire transmitters, the MTL7700 range provides a bussed power feed facility. When used in conjunction with the MTL7798 power feed module the user has a fully protected, electronically fused supply to many barriers with no additional wiring required.
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
All MTL7700 Series barriers are based on the same simple principle. Each channel contains two stages of pulse-tested Zener or forward connected diodes and an ‘infallible’ terminating resistor. In the event of an electrical fault in the safe area, the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes, and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output current limiting circuits are employed. All models (except MTL7707P+ and MTL7729P+, ‘ia’ ‘IIB’) are certified ‘ia’ for all zones and ‘IIC’ for all explosive atmospheres.
Features
* Removable terminals for easy cabling
* Bussed power feed to other modules
* Relay and solid state switch modules
* Dual channel variants: 6.3mm per channel
* Barrier protection module
* Proximity detector inputs
* Electronic fusing
* Direct replacement for MTL700 Series barriers
* Compatible terminal numbering and safety descriptions
Application of MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
Here’s how some of our customers use this product…
Protecting Sensor Circuits in a Hazardous Location
The Background: Our customer is a ceramics manufacturer seeking a means to protect sensor circuits in a hazardous area location.
The Problem: The customer utilizes methanol during the annealing process. As a highly flammable substance, the storage area for the methanol is classified as a hazardous area. As such, they must have intrinsically safe barriers for all sensor circuits that pass into the methanol storage area.
The Solution: We recommended MTL7700 Intrinsically Safe Barriers. The 7700 is a shunt-diode barrier that limits the amount of energy allowed to pass between safe and hazardous areas to a level that cannot ignite flammable atmospheres. They are DIN-rail mounted which provides quick and easy installation without the need for special hardware.
Ordering models of MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
Ordering Codes of MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
Part Number & Description of MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
Digital Input MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4501-SR 1ch DI failsafe solid-state output + LFD alarm
MTL4504 1ch DI relay output + LFD alarm + phase reversal
MTL4510 4ch DI solid-state output
MTL4510B 4ch DI multifunction solid-state output
MTL4511 1ch DI relay output
MTL4513 2ch DI solid-state output
MTL4514/B 1ch DI relay output + LFD alarm
MTL4516 2ch DI relay output
MTL4516C 2ch DI with changeover relay output
MTL4517 2ch DI relay output + LFD alarm
Digital Output MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4521 Loop powered solenoid driver
MTL4521L Loop powered solenoid driver IIC
MTL4523 Solenoid driver with LFD
MTL4523L Loop powered solenoid driver + LFD
MTL4523R Solenoid driver with LFD
MTL4523V/VL Solenoid/Alarm driver with voltage control
MTL4524 Switch operated solenoid driver
MTL4524S Switch operated solenoid driver, 24V override
MTL4525 Switch operated solenoid driver low power
MTL4526 2ch switch operated relay
Analogue Input MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4541 1ch 2/3 wire Transmitter repeater
MTL4541A 1ch Transmitter repeater, passive input
MTL4541AS 1ch Transmitter repeater, passive input, current sink
MTL4544D 2/3 wire transmitter repeater, dual output
MTL4544S 2ch 2/3 transmitter repeater, current sink
Analogue Output MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4546 1ch 4-20mA smart isolating driver + LFD
MTL4546C 1ch 4-20mA smart isolating driver + oc LFD
MTL4546Y 1ch 4-20mA smart isolating driver + oc LFD
MTL4549 2ch 4-20mA smart isolating driver + LFD
MTL4549C 2ch 4-20mA smart isolating driver + oc LFD
MTL4549Y 2ch 4-20mA smart isolating driver + oc LFD
Temperature Input MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4575 1ch Temperature converter with alarm
MTL4576-RTD 2ch Temperature converter, RTD
MTL4576-THC 2ch Temperature converter, THC
MTL4581 1ch mV/THC isolator for low-level signals
Pulse and Vibration MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4531 1ch vibration probe interface
MTL4532 1ch pulse isolator, digital or analogue output
MTL4533 2ch vibration probe interface
Fire and Smoke MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4561 2ch loop-powered, for fire and smoke detectors
General MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL4599 Dummy isolator
MTL4599N General purpose feed-through module
MTL4500 Series Barriers MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
MTL7796+ / MTL7796- Shunt-Diode Safety Barrier for Vibration Probes, 2-Channel
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers,Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.