Safety Barriers

MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

MTL Safety Barriers

MTL5541 Repeater Power Supply

ModelMTL5541

Repeater power supply for 2- or 3-wire 4/20 mA or HART transmitters. Channels: One; safe-area output: 4–20 mA, load 0–450 Ω at 20 mA; transmitter voltage: 16.5 V at 20 mA.

Channels
One
Safe-area output
4–20 mA, load 0–450 Ω at 20 mA
Transmitter voltage
16.5 V at 20 mA
Transfer accuracy
Better than 15 µA at 20 °C

Availability and lead time confirmed on request

Overview

MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

Description of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

The following guide is for users who require guidance on their choice of isolator for a new installation. For a given application the choice is between DIN-rail mounting (MTL5000/MTL5500 range) and backplane mounting (MTL4000/MTL4500 range) devices.

MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

Analogue Input – 2-wire transmitters, 4-20mA conventional and ‘smart’

DeviceNo. of

channelsOutput to

hazardous areaImportant features

DIN-rail mounting devices of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

MTL5541116.5V min.

@ 20mACompatible with most smart transmitters

MTL5541A18.6V diodeSeparately powered smart transmitters

MTL5541AS18.6V diode4 wire smart transmitters, current sink output

MTL5541S116.5V min.

@20mACompatible with most smart transmitters, current sink output

MTL5544216.5V min

@ 20mACompatible with most smart transmitters

MTL5544A28.6V diodeSeparately powered smart transmitters

MTL5544AS28.6V diode4 wire smart transmitters, current sink output

MTL5544D116.5V min

@ 20mACompatible with most smart transmitters, repeat output

MTL5544S216.5V min

@ 20mACompatible with most smart transmitters, current sink output

Backplane mounting devices of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

MTL4541116.5V min

@ 20mACompatible with most smart transmitters

MTL4541A18.6V diodeSeparately powered smart tranmitters

MTL4541P117.6V min

@ 20mAAs MTL4541B but with a higher power output, MTL4041P substitution on legacy backplanes

MTL4541S116.5V min

@ 20mACompatible with most smart transmitters, current sink output

MTL4544216.5V min

@ 20mACompatible with most smart transmitters

MTL4544A28.6V diodeSeparately powered smart transmitters

transducerCompatible with vibration and accelerometer transducers

Analogue Input – thermocouple and mV sources of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsOutput to

safe areaMain features

DIN-rail mounting devices

MTL557314/20mAConfigurable, built-in CJC, early burnout detection facility

MTL557514/20mAConfigurable, built-in CJC, early burnout detection facility, alarm output

MTL5576-THC24/20mAConfigurable, built-in CJC, also config as 1in 2 out

MTL558110 to ±50mVSelectable upscale or downscale

Backplane mounting devices

MTL457314/20mAConfigurable, built-in CJC, early burnout detection facility

MTL457514/20mAConfigurable, built-in CJC, early burnout detection facility, alarm output

MTL4576-THC24/20mAConfigurable, built-in CJC, also config as 1in 2 out

MTL458110 to ±50mVSelectable upscale or downscale

Analogue Input – 2, 3 and 4-wire RTDs of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsOutput to

safe areaMain features

DIN-rail mounting devices

MTL557314/20mAConfigurable, many sensor types and ranges

MTL557514/20mAConfigurable, many sensor types and ranges, alarm output

MTL5576-RTD24/20mAConfigurable, also config as 1in 2 out

MTL5582B110 to 400 ohmIndependent selection of 2, 3 or 4-wire RTDs on safe and hazardous area sides

Backplane mounting devices

MTL457314/20mAConfigurable, many sensor types and ranges

MTL457514/20mAConfigurable, many sensor types and ranges, alarm output

MTL4576-RTD24/20mAConfigurable, also config as 1in 2 out

Analogue Output – controller outputs, I/P converters of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsOutput to

hazardous areaImportant features

DIN-rail mounting devices

MTL554611mA Vmax = 16VSuitable for HART valve positioners, SC & OC LFD

MTL5546Y11mA Vmax = 16VSuitable for HART valve positioners, OC LFD

MTL554921mA Vmax = 16VSuitable for HART valve positioners, SC & OC LFD

MTL5549Y21mA Vmax = 16VSuitable for HART valve positioners, OC LFD

Backplane mounting devices

MTL454611mA Vmax = 16VSuitable for HART valve positioners, SC & OC LFD

MTL4546Y11mA Vmax = 16VSuitable for HART valve positioners, OC LFD

MTL454921mA Vmax = 16VSuitable for HART valve positioners, SC & OC LFD

MTL4549Y21mA Vmax = 16VSuitable for HART valve positioners, OC LFD

Digital Input – switches / proximity detectors of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsOutput to

safe areaImportant features

DIN-rail mounting devices

MTL551044 x solid stateCan switch +ve or –ve polarity signals

MTL5510B44 x solid stateMult-function selectable

MTL551111 x SPDTSwitch/proximity detector repeater

MTL551322 x solid statedc to 500Hz frequency response

MTL551411 x SPDT

1 x SPDTSwitch/proximity detector repeater

Independent LFD output

MTL5514D12 x SPDTDual output switch/proximity detector repeater

MTL5516C22 x SPDTSwitch/proximity detector repeater

MTL551722 x SPDT

1 x SPDTSwitch/proximity detector repeater

Independent LFD output

Backplane mounting devices

MTL450411 x SPDT

1 x SPDTSwitch/proximity detector repeater

Independent LFD output, de-energise to alarm

MTL451044 x solid stateCan switch +ve or –ve polarity signals

MTL4510B44 x solid stateMult-function selectable

switches +ve, -ve or ac signals

MTL451111 x SPDTSwitch/proximity detector repeater

MTL451322 x solid statedc to 500Hz frequency response

MTL451411 x SPDT

1 x SPDTSwitch/proximity detector repeater

Independent LFD output, energise to alarm

MTL4514D12 x SPDTDual output switch/proximity detector repeater

MTL451622 x SPSTSwitch/proximity detector repeater

MTL4516C22 x SPDTSwitch/proximity detector repeater

MTL451722 x SPST

1 x SPDTSwitch/proximity detector repeater

Independent LFD output

Digital Input – switch/proximity detectors, SIL3 of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsSignals monitoredImportant features

DIN-rail mounting devices

MTL5501-SR124V logicSafety related, SIL3 certified

Backplane mounting devices

MTL4501-SR124V logicSafety related, SIL3 certified

Digital Output – alarms, LEDs, solenoid valves, etc of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsOutput to

hazardous areaImportant features

DIN-rail mounting devices

MTL5521112.8V Imax = 48mAIIC gas groups, loop powered

MTL552219.9V Imax = 70mAIIB gas groups, loop powered

MTL5523112.8V Imax = 48mASwitch controlled input, Independent LFD output

MTL5523V112.8V Imax = 48mAVoltage controlled input, Independent LFD output

MTL5524112.8V Imax = 48mASafety override feature, separately powered

MTL552517V Imax = 48mALow power output, loop powered

Backplane mounting devices

Digital Output – switch output to hazardous area of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsSignals monitoredImportant features

DIN rail mounting devices

MTL55261 or 22 x DPDTSafe-area switch input or loop powered.

2ch or 1ch with 2 outputs

Backplane mounting devices

MTL45261 or 22 x DPDTSafe-area switch input or loop powered.

2ch or 1ch with 2 outputs

Pulse Input – turbine / flowmeters of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsInput from

hazardous areaImportant features

DIN-rail mounting devices

MTL55321Switch, proximity detector, current pulse, voltage pulseVoltage and current inputs from 2 or 3-wire transmitters

configurable 4-20mA analogue output

MTL554112-wire pulsee.g. 2-wire turbine and vortex flowmeters

Backplane mounting devices

MTL453211mA Vmax = 16VVoltage and current inputs from 2 or 3-wire transmitters

configurable 4-20mA analogue output

MTL454112-wire pulsee.g. 2-wire turbine and vortex flowmeters

Fire / Smoke detectors of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsOutput to

hazardous areaImportant features

DIN-rail mounting devices

MTL55612Loop powered0–40mA, fire and smoke detectors

Backplane mounting devices

MTL45612Loop powered0–40mA, fire and smoke detector

Signal transfer – safe area to safe area – via hazardous area of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

Device

pairNo. of

channelsSignal transferredImportant features

DIN-rail mounting devices

MTL5546Y &

MTL5541A14/20mA smartDriver

Receiver

MTL5526 &

MTL5516C2Status signalsDriver, relay output

Receiver, digital output

MTL50511RS232 or RS422Either can be used as receiver or driver

Backplane mounting devices

MTL4546Y &

MTL4541A14/20mA smartDriver

Receiver

MTL4526 &

MTL45162Status signalsDriver, relay output

Receiver, digital output

Trip amplifiers of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

DeviceNo. of

channelsSignals monitoredImportant features

DIN-rail mounting devices

MTL531414/20mAConfigurable, one or two alarms

PRODUCT LITERATURE of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

Product CodeDescription

intrinsically safe logo Symbol denotes that the equipment is suitable for use in hazardous area applications.

fsm logo Symbol denotes that the product has been assessed for functional safety applications.

SM45-55-AI SM45-55-AI is FSMFSM Safety Manual – Analogue Input Modules

SM45-55-AO SM45-55-AO is FSMFSM Safety Manual – Analogue Output Modules

SM45-55-BI SM45-55-BI is FSMFSM Safety Manual – Binary Input Modules

SM45-55-MMI SM45-55-MMI is FSMFSM Safety Manual – Machine Monitor Interfaces

SM45-55-SAD SM45-55-SAD is FSMFSM Safety Manual – Solenoid / Alarm Driver Modules

1. Intro of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

INA4500MTL4500/4600 range Instructions for Safe Use

INM4500/4600MTL4500/4600 range Instruction Manual

MTL4500-5500-ACCBackplanes, Enclosures & Accessories

MTL4500-5500-CSCommon Specifications

MTL4500-5500-DSMTL4500-5500 range Data Set

MTL4525 MTL4525 is intrinsically safe MTL4525 is FSMSwitch operated solenoid driver low power

8. Fire and Smoke of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

MTL4561 MTL4561 is intrinsically safe MTL4561 is FSM2ch loop-powered, for fire and smoke detectors

9. General of MTL5541 Repeater Power Supply, 1-Channel, 4–20 mA HART

MTL4599Dummy isolator

MTL4599NGeneral purpose feed-through module

Specifications

FunctionRepeater power supply for 2- or 3-wire 4/20 mA or HART transmitters
ChannelsOne
Safe-area output4–20 mA, load 0–450 Ω at 20 mA
Transmitter voltage16.5 V at 20 mA
Transfer accuracyBetter than 15 µA at 20 °C
Response timeSettles within 10 % of final value within 50 µs
Supply20–35 V DC; 51 mA at 24 V
HARTSupported (terminals 1 & 2)

Source: MTL (Eaton) data sheet MTLx541/S. Confirm with the manufacturer datasheet before ordering.

Documents

  • DatasheetPDF · on request Request
  • Operating manualPDF · on request Request
  • Certificate copy (with order, where available)PDF · on request Request