Product News

Endress+Hauser Prosonic FMU30 Non-Contact Level News

News October 20, 2026

E+H Prosonic T · Product News · 20 October 2026

Endress+Hauser Prosonic FMU30: Choose the Sensor Size Before Comparing the Price

For urgent replacement or project sourcing, quote the complete reference: FMU30 FMU30-AAHEAAGGF. The family name alone cannot confirm the process connection, approval, output or suitability for the actual echo conditions.

Endress+Hauser Prosonic FMU30 ultrasonic level transmitter supplier    

E+H level instrument stock and project sourcing — request availability with the complete order code.

Supply-chain alert: a familiar family name can still produce the wrong replacement

A quotation that confirms only the model family leaves the installation team to resolve sensor size, thread compatibility and documentation during the shutdown. For a water or wastewater tank, that handover gap can turn a quick replacement into extra commissioning work. For FMU30 sourcing, settle these questions before dispatch: sensor size, G/NPT thread and seal material, hazardous-area approval, power and analogue output, process medium, mounting geometry, and the actual measuring distance. Send the full code FMU30-AAHEAAGGF together with application data at the first enquiry so commercial availability and technical fit can be checked in parallel.

FMU30 sourcing: two sensor sizes with a mechanical interface to verify

The Endress+Hauser Prosonic FMU30 is a two-wire ultrasonic transmitter for non-contact level measurement. It is used in sewage treatment, process-water vessels, loading systems, storage tanks and buffer tanks. Its 4–20 mA output supports conventional analogue loops; specify the required interface explicitly when replacing another transmitter.

Measuring principleUltrasonic, continuous non-contact level and flow measurement
Maximum distance1½-inch sensor: liquids 5 m, solids 2 m; 2-inch sensor: liquids 8 m, solids 3.5 m
Blocking distance1½-inch sensor: 0.25 m; 2-inch sensor: 0.35 m
Accuracy±3 mm or ±0.2% of the set measuring range
Process temperature-20°C to +60°C (-4°F to +140°F)
Process pressure0.7 to 3 bar absolute (10 to 44 psi)
Connection / wetted partG/NPT 1½ or 2 inch thread; PP/EPDM sensor
Communication4–20 mA; compact two-wire configuration

The real engineering question: will the echo remain usable?

FMU30 has two sensor sizes with different liquid ranges, solid ranges and blind zones. A quote based only on the largest family range can hide a mismatch. Confirm the configured sensor, thread and usable measuring span before ordering. Foam, strong surface turbulence, heavy dust, filling curtains, vapour, temperature gradients, vessel internals and poor nozzle position can weaken or multiply echoes. The actual usable range therefore depends on the measuring conditions. This is why an honest quotation should begin with the medium and geometry rather than only the words “0–8 metres.”

The blocking distance is 0.25 m for the 1½-inch sensor and 0.35 m for the 2-inch sensor. Product must not enter this near-sensor zone at maximum level. A replacement mounted too low may be commercially correct yet operationally unsuitable.

Diagnostics that shorten commissioning

The on-site display can show the envelope curve for echo diagnosis, while menu-guided operation supports commissioning. Integrated temperature measurement compensates for changes in the speed of sound, while the four-line display and envelope curve help with on-site echo diagnostics.

Send these details for a useful stock and lead-time answer

  1. Complete order code: FMU30-AAHEAAGGF, not only “FMU30”.

  2. Medium: liquid, paste or bulk solid; include foam, dust or vapour conditions.

  3. Geometry: tank height, nozzle size and length, maximum level and nearby obstructions.

  4. Process: temperature, pressure, agitation and filling/discharge behaviour.

  5. Electrical and approval needs: output, power, hazardous-area certificate and destination country.

  6. Commercial timing: required quantity, delivery location and shutdown deadline.

FMU30 buying questions

What is the maximum range of an E+H FMU30?

The published maximum is 5 m for liquids and 2 m for solids with the 1½-inch sensor, or 8 m for liquids and 3.5 m for solids with the 2-inch sensor. Real performance depends on surface and installation conditions, so the application should be reviewed before treating that number as a guaranteed working range.

Can FMU30 measure without touching the product?

Yes. Ultrasonic pulses measure distance to the surface without a probe in the medium. Check foam, turbulence, vapour and the sensor’s blocking distance when evaluating the installation.

What information is needed for an FMU30 quotation?

Provide the complete order code, medium, measuring distance, nozzle and tank geometry, temperature, pressure, approvals, quantity and delivery destination. For this enquiry, use FMU30 FMU30-AAHEAAGGF.

E+H level instruments currently receiving enquiries

Every request should include the full configured model. The following references are supplied as search and enquiry examples; availability must be confirmed against quantity and destination.

SeriesComplete enquiry reference
FMR43FMR43-AABADFNX1X2JGFC+TC
FMR20BFMR20B-AABADTBMVCGVEEB
FMR10BFMR10B-AAAADTBMWDGWEEB
FMR30BFMR30B-AABAKHBMXQ0VEE3
FMR67FMR67B-AABAFBCJGPEBESJD1+EH
FMR62FMR62-NBBCAAGMF5MRK
FMR60FMR60-AAALAAGAA3XJG
FWR30FWR30-AA1B1B7B0+PC
FMR20FMR20-AAABNWDEXR01
FMR10FMR10-AAQBMWDEWFE2
NMR84NMR84-IC1BB1C2B1ACABFB1AHJITD
NMR81NMR81-BC2BA1A2X0ACEACB2AFJNTC+AALAR1R3
FMR67BFMR67B-AABAENAFGAJCRBFD3
FMR66BFMR66B-AABAEDAHBSI1WFEA
FMR62BFMR62B-AABACAAJGNEBEUKB+AA
FMR60BFMR60B-AABAEJAFBSJCRCFA+LA
FMR54FMR54-AAACCABDD1AJJ+AAEHJALA
FMR52FMR52-BCACCBBPAGK+AA
FMR51FMR51-BBACCABCA5AGJ
FMP50FMP50-BCACCBAAA1GDJ+AAF371,2M
FMP51FMP51-BAACCABCB3ARJ+AA, 7000MM
FMP52FMP52-AAACCAOACHK+AAIJZ1 (2050MM)
FMP53FMP53-AAACCADAB5TDJ L=560 mm
FMP54FMP54-BCEEBBAED1AHJ+EBEHF4JAJBKEOAPBZ1 (LENGTH:2030MM)
FMP55FMP55-BAACBACAATK +AAEHF4I7JBJDOEPBZ1 CA=2750MM
FMP56FMP56-AAAAAALAABGDE
FMP57FMP57-AAACCAAEA4GGE (2000mm)
FMU40FMU40-ARB2A2
FMU41FMU41-1NB2A2
FMU42FMU42-AVB2A42A
FMU44FMU44-ATB2A23A
FMU30FMU30-AAHEAAGGF
FMG50FMG50-AABADJACA

Request FMU30 price, stock and lead time

Send FMU30-AAHEAAGGF, quantity, destination and application data. Ask us to check available units, documentation and dispatch options before confirming your maintenance date.

becky@hkxytech.com

+86 15972186287

Endress+Hauser and Prosonic are trademarks of their respective owner. Specifications should be confirmed against the selected order code and current manufacturer documentation.

CONTACT ADDRESS

RM 509 5/F, THE CLOUD, 111 TUNG CHAU STREET, TAI KOK TSUI, KOWLOON, HONG KONG

WRITE TO US

becky@hkxytech.com

CALL US

+86 027-8580 6199

MOBILE PHONE

+86 15972186287